Current Transducer LAH 100-P
For the electronic measurement of currents : DC, AC, pulsed ..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN = 100 A
16052
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance @ with ± 12 V
1)
100 0 .. 160 TA = 70°C TA = 85°C RM min RM max RM min RM max
A A
Features
• Closed loop (compensated) current
transducer using the Hall effect
ISN KN VC IC Vd Ve Vw X
@ IPN [± A DC ] 0 63 0 57 @ IPN [A RMS ] 2) 0 11 0 5 with ± 15 V @ IPN [± A DC ] 20 120 45 114 @ IPN [A RMS ] 2) 20 51 45 45 @ IP < IPN 3) Secondary nominal r.m.s. current 50 Conversion ratio 1 : 2000 Supply voltage (± 5 %) ± 12 .. 15 Current consumption 10 (@ ± 15 V)+IS R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 5 R.m.s. voltage for partial discharge extinction @ 10 pC > 2 Impulse withstand voltage 1.2/50 µs > 12
Ω Ω Ω Ω mA V mA kV kV kV
• Printed circuit board mounting • Insulated plastic case recognized
according to UL 94-V0.
Advantages
• • • • • • •
Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference • Current overload capability.
Accuracy - Dynamic performance data
ε
L
Accuracy 4) @ IPN, TA = 25°C Linearity error Offset current @ TA = 25°C Residual current @ IP = 0, after an overload of 5 x IPN Thermal drift of IO 0°C .. + 70°C - 25°C .. + 85°C Reaction time @ 10 % of IPN Response time 5) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB)
± 0.25 < 0.15 Max ± 0.15 ± 0.10 ± 0.15 ± 0.10 ± 0.40 ± 0.10 ± 0.50 < 200 < 500 > 200 DC .. 200 Typ
% % mA mA mA mA ns ns A/µs kHz
Applications
• AC variable speed drives and servo
motor drives
IO IOM IOT tr a tr di/dt f
• Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
General data
TA TS RS Ambient operating temperature Ambient storage temperature Secondary coil resistance Insulating material group Mass Standards
1) 3)
• Power supplies for welding
- 25 .. + 85 °C - 40 .. + 90 °C 115 Ω 121 Ω I 24 g EN 50178 : 1997 applications.
@ TA = 70°C @ TA = 85°C
m
Notes :
For 10 s, with RM ≤ 25 Ω (VC = ± 15 V) - 2) 50 Hz Sinusoidal The measuring resistance RM min may be lower (see "LAH Technical Information" leaflet) - 4) Without IO & IOM - 5) With a di/dt of 100 A/µs.
0 60303/8
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. page 1/2
LEM
w w w .lem.com
Dimensions LAH 100-P
(in mm. 1 mm = 0.0394 inch)
Connection
Bottom view
Left view
Front view
Number of primary turns
Primary current nominal maximum
Nominal output current
Turns ratio
Primary resistance
Primary insertion inductance
IPN [ A ] 100
IP
[A] 160
ISN
[ mA ] 50
KN 1 : 2000
RP
[ mΩ ] 0.08
LP 0.007
[ µH ]
1
Mechanical characteristics
• General tolerance • Fastening & connection of primary
Recommended PCB hole • Fastening & connection of secondary Recommended PCB hole ± 0.2 mm 6 pins 1.4 x 1 mm 2 mm 3 pins 0.7 x 0.6 mm 1.2 mm
Remarks
• IS is positive when IP flows from terminals "IN" to terminals
"OUT".
• The jumper temperature and PCB should not exceed 100°C. • This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...), please contact us.
0 60303/8
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
page 2/2
LEM
w w w .lem.com