Current Transducer LF 2005-S
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
2000 A
16103
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range @ ± 24 V Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC Vd @ ± 2000 A max @ ± 2200 A max @ ± 2000 A max @ ± 3000 A max 2000 0 .. ± 3000 RM min RM max 0 0 5 5 8 5 29 11 A A Ω Ω Ω Ω
Features
• Closed loop (compensated) current
transducer using the Hall effect
• Insulated plastic case recognized
according to UL 94-V0.
Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
400 mA 1 : 5000 ± 15 .. 24 V 33 (@ ± 24 V) + IS mA 6 kV
Advantages
• • • • • • •
Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference • Current overload capability.
Accuracy - Dynamic performance data
XG
ε
L
Overall accuracy @ IPN , TA = 25°C Linearity error Offset current @ IP = 0, TA = 25°C Thermal drift of IO - 25°C .. + 70°C Response time 1) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB)
± 0.3 < 0.1 Typ Max ± 0.5 ± 0.4
% % mA mA µs A/µs kHz
IO IOT tr di/dt f
Applications
• AC variable speed drives and servo
motor drives
± 0.2
50 DC .. 100
• Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies
(UPS)
General data
TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 70°C Mass Standards 2) - 25 .. + 70 - 40 .. + 85 25 1.5 EN 50178 °C °C Ω kg
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Notes :
1) 2)
With a di/dt of 100 A/µs A list of corresponding tests is available.
060425/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 1/2
LEM
w w w .lem.com
Dimensions LF 2005-S
Front view
(in mm. 1 mm = 0.0394 inch)
Left view
Secondary terminals
Pin Pin Pin + M : supply voltage + 15 .. 24 V : measure : supply voltage - 15 .. 24 V
Connection
Top view Mechanical characteristics
• General tolerance • Fastening transducer
Flat or vertical position Fastening torque • Primary through-hole • Connection of secondary ± 0.5 mm 4 holes ∅ 6.5 mm 4 screw M6 steel 5.5 Nm or 4.05 Lb. - Ft. 60.5 x 60.5 mm S3P-VH
Remarks
• IS is positive when IP flows in the direction of the arrow. • Temperature of the primary conductor should not exceed
100°C.
• Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...), please contact us.
060425/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Page 2/2
LEM
w w w .lem.com
很抱歉,暂时无法提供与“LF2005-S”相匹配的价格&库存,您可以联系我们找货