Current Transducer LF 205-P
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
200 A
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance @ with ± 12 V with ± 15 V ISN KN VC IC Vd @ ± 200 A max @ ± 420 A max @ ± 200 A max @ ± 420 A max 200 0 .. ± 420 TA = 70°C TA = 85°C RM min RM max RM min RM max 0 0 0 0 71 14 100 28 0 0 23 23 69 12 98 26 A A
Features
• Closed loop (compensated) current
transducer using the Hall effect
Ω Ω Ω Ω mA V mA kV
• Insulated plastic case recognized
according to UL 94-V0.
Advantages
• • • • • • •
Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference • Current overload capability.
Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption @ ± 15V R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
100 1 : 2000 ± 12 .. 15 17 + IS 3.5
Accuracy - Dynamic performance data
XG
ε
L
Overall accuracy @ IPN , TA = 25°C Linearity
± 0.5 < 0.1 Max ± 0.2 ± 0.1 ± 0.4
% % mA mA mA ns µs A/µs kHz
IO I OM IOT tra tr di/dt f
Typ Offset current @ IP = 0, TA = 25°C Residual current 1) @ IP = 0, after an overload of 3 x IPN Thermal drift of IO - 40°C .. + 85°C ± 0.12 Reaction time @ 10 % of IP max Response time2) @ 90 % of IP max di/dt accurately followed Frequency bandwidth (- 3 dB)
Applications
• AC variable speed drives and servo
motor drives
< 500 100 DC .. 100
• Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies
(UPS)
General data
TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 70°C @ TA = 85°C Mass Standards 3) - 40 .. + 85 - 40 .. + 90 33 35 58 EN 50178 °C °C Ω Ω g
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Notes :
1) 2) 3)
The result of the coercive field of the magnetic circuit With a di/dt of 100 A/µs A list of corresponding tests is available. 011120/2
LEM Components
w w w.lem.com
Dimensions LF 205-P (in mm. 1 mm = 0.0394 inch)
Bottom view Secondary terminals
Terminal + : supply voltage + 12 .. 15 V Terminal M : measure Terminal - : supply voltage - 12 .. 15 V
Front view
Left view
Back view
Connection
Top view Mechanical characteristics
• General tolerance • Fastening & secondary connection
Recommanded PCB hole ± 0.2 mm 3 pins 0.63x0.56 mm ∅ 0.9 mm ∅ 15.5 mm 2 holes ∅ 1.75 mm 2.4 mm KA22 x 6 47.30.60.006.0
Remarks
• IS is positive when IP flows in the direction of the arrow. • Temperature of the primary conductor should not exceed
100°C.
• Primary through-hole • Supplementary fastening
Recommended PCB hole Recommended screws LEM code
• Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...), please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
很抱歉,暂时无法提供与“LF205-P”相匹配的价格&库存,您可以联系我们找货
免费人工找货