Current Transducer LT 108-S7/SP1
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit and the secondary
circuit.
Electrical data
Features
IPN
Primary nominal current rms
IPM
Primary current, measuring range
R M
Measuring resistance
with ± 12 V
@ ± 100 A max
@ ± 150 A max
with ± 15 V
@ ± 100 A max
@ ± 150 A max
ISN
Secondary nominal current rms
KN
Conversion ratio
V C
Supply voltage (± 5 %)
IC
Current consumption
100
A
0 .. ± 150
A
RM min RM max
0 136 Ω
0 74
Ω
0
175
Ω
0 106 Ω
50
mA
1 : 2000
± 12 .. 15
V
20 (@ ± 15 V) + IS mA
Accuracy - Dynamic performance data
XG
εL
IOE
IOM
IOT
tra
tr
di/dt
BW
Overall accuracy @ IPN , TA = 25°C
± 0.6
%
Linearity error
< 0.1
%
Typ Max
Electrical offset current @ IP = 0, TA = 25°C
± 0.15 mA
Magnetic offset current 1) @ IP = 0, and specified RM,
after an overload of 3 x IPN
± 0.10 mA
Temperature variation of IO
- 10°C .. + 70°C ± 0.20 ± 0.64 mA
Reaction time to 10 % of IPN step
< 500
ns
Response time 2) to 90 % of IPN step
< 1
µs
di/dt accurately followed
> 100
A/µs
Frequency bandwidth (- 3 dB)
DC .. 100
kHz
General data
TA
TS
RS
m
Notes:
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ TA = 70°C
Mass
Standard
1)
2)
IPN = 100 A
Result of the coercive field of the magnetic circuit
With a di/dt of 100 A/µs.
- 10 .. + 70
°C
- 25 .. + 80
°C
32
Ω
76
g
EN 50178: 1997
●● Closed loop (compensated)
current transducer using the Hall
effect
●● Isolated plastic case recognized
according to UL 94-V0.
Special feature
●● Secondary connection on
JTB450-00.
Advantages
●●
●●
●●
●●
●●
●●
●●
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
●● Current overload capability.
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application Domain
●● Industrial.
Page 1/3
24September2012/version 4
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Current Transducer LT 108-S7/SP1
Isolation characteristics
Vd
Vw
dCp
dCI
CTI
Rms voltage for AC insulation test 1), 50 Hz, 1 min
Impulse withstand voltage 1.2/50 µs
Creepage distance 2)
Clearance 2)
Comparative Tracking Index (group IIIa)
Notes:
1)
2)
3.52
6.5
Min
10
6
275
kV
kV
mm
mm
Between primary and secondary
On housing.
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
●● Over voltage category OV 3
●● Pollution degree PD2
●● Non-uniform field
EN 50178
IEC 61010-1
Rated insulation voltage
Nominal voltage
Basic insulation
600 V
600 V
Reinforced insulation
300 V
300 V
dCp, dCI, Vw
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
24September2012/version 4
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Dimensions LT 108-S7/SP1 (in mm)
Connection
Mechanical characteristics
●● General tolerance
●● Transducer fastening
Recommended fastening torque
Or
Recommended fastening torque
●● Primary through-hole
●● Connection of secondary
Remarks
± 0.5 mm
2 holes Ø 5.4 mm
2 M5 steel screws
1.5 Nm (± 10 %)
2 notches 4.2 mm
2 M4 steel screws
0.75 Nm (± 10 %)
Ø 20 mm
Socket JTB450-00
(JITE, Shenzhen)
●● IS is positive when IP flows in the direction of the arrow.
●● Temperature of the primary conductor should not exceed
100°C.
●● Dynamic performances (di/dt and response time) are
best with a single bar completely filling the primary hole.
Page 3/3
24September2012/version 4
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
很抱歉,暂时无法提供与“LT108-S7/SP1”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+166.86000
- 10+161.46000