Current Transducer LT 2005-S
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
=
2000 A
Electrical data
IPN IP RM Primary nominal r.m.s. current Primary current, measuring range @ ± 24 V Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC Vd @ ± 2000 A max @ ± 2200 A max @ ± 2000 A max @ ± 3000 A max 2000 0 .. ± 3000 RM min RM max 0 0 5 5 7.5 4 27.5 10 A A Ω Ω Ω Ω
Features
•Closed loop (compensated) current
transducer using the Hall effect
•Insulated plastic case recognized
according to UL 94-V0.
Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
400 mA 1 : 5000 ± 15 .. 24 V 20 (@ ± 24 V) + IS mA 6 kV
Advantages
•Excellent accuracy •Very good linearity •Low temperature drift •Optimized response time •Wide frequency bandwidth •No insertion losses •High immunity to external
interference
Accuracy - Dynamic performance data
XG
ε
L
Overall accuracy @ IPN , TA = 25°C Linearity Offset current @ IP = 0, TA = 25°C Thermal drift of IO Response time @ 90 % of IP max di/dt accurately followed Frequency bandwidth (- 1 dB)
1)
± 0.3 < 0.1 Typ Max ± 0.8 ± 0.3
% % mA mA µs A/µs kHz
•Current overload capability.
IO IOT tr di/dt f
Applications
•AC variable speed drives and servo
motor drives
0°C .. + 70°C
± 0.2
50 DC .. 100
•Static converters for DC motor drives •Battery supplied applications •Uninterruptible Power Supplies
(UPS)
General data
TA TS RS m Ambient operating temperature Ambient storage temperature Secondary coil resistance @ TA = 70°C Mass Standards 2) 0 .. + 70 - 25 .. + 85 25 1.5 EN 50178 °C °C Ω kg
•Switched Mode Power Supplies
(SMPS)
•Power supplies for welding
applications.
Notes :
1) 2)
With a di/dt of 100 A/µs A list of corresponding tests is available 980806/4
LEM Components
w w w .lem.com
Dimensions LT 2005-S
Front view
(in mm. 1 mm = 0.0394 inch)
Left view
Secondary terminals
Terminal + : supply voltage + 15 .. 24 V Terminal M : measure Terminal - : supply voltage - 15 .. 24 V
Connection
Top view Mechanical characteristics
•General tolerance •Fastening •Primary through-hole •Connection of secondary
Fastening torque ± 0.5 mm 4 holes ∅ 8.5 mm 60.5 x 60.5 mm M5 threaded studs 2.2 Nm or 1.62 Lb - Ft
Remarks
•IS is positive when IP flows in the direction of the arrow. •Temperature of the primary conductor should not exceed
100°C.
•Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
•This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...), please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.