Current Transducer LTC 1000-T
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN =
1000 A
Electrical data
IPN IP ÎP RM Primary nominal r.m.s. current Primary current, measuring range @ 24 V Max overload not measurable Measuring resistance with ± 15 V with ± 24 V ISN KN VC IC Vd Ve @ ± 1000 A max @ ± 1200 A max @ ± 1000 A max @ ± 2000 A max 1000 A 0 .. ± 2400 1) A 10 / 10 kA/ms RM min RM max 0 0 0 0 15 7 50 7 Ω Ω Ω Ω mA V mA kV kV kV
Features
• Closed loop (compensated) current
transducer using the Hall effect
• Insulated plastic case recognized
according to UL 94-V0
• Railway equipment.
Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn R.m.s. voltage for partial discharge extinction
200 1 : 5000 ± 15 .. 24 < 30 (@±24V) +IS 13.4 2) 1.5 3) > 2.8
Advantages
• • • • • • •
Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference • Current overload capability.
Accuracy - Dynamic performance data
XG Overall accuracy @ IPN , TA = 25°C @ IPN , TA = - 40°C .. + 85°C Linearity Offset current @ IP = 0, TA = 25°C Thermal drift of IO Response time 4) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB) < ± 0.4 5 A/µs Between primary and secondary + shield Between secondary and shield With a di/dt of 100 A/µs. 030528/0
LEM Components
w w w.lem.com
Dimensions LTC 1000-T (in mm. 1 mm = 0.0394 inch)
Front view Left view
Secondary terminals
Terminal + : supply voltage + 15 .. 24 V Terminal M : measure Terminal - : supply voltage - 15 .. 24 V Terminal E : shield
Connection
or
Top view Mechanical characteristics
• General tolerance • Fixing the transducer
± 1 mm 2 holes ∅ 1 3 mm or by the primary bar 2 steel screws M12 24.5 Nm M5 threaded studs 2.2 Nm or 1.62 Lb.-Ft. Faston 6.3 x 0.8 mm
Remarks
• IS is positive when IP flows in the direction of the arrow. • Temperature of the primary conductor should not exceed
100°C.
• Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
Fastening torque max
• Connection of secondary
Fastening torque max
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.