Voltage Transducer LV 100-2500
For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit).
VPN =
2500 V
Electrical data
VPN VP IPN RM Primary nominal r.m.s. voltage Primary voltage, measuring range Primary nominal r.m.s. current Measuring resistance with ± 15 V ISN KN VC IC Vd @ ± 2500 V max @ ± 3750 V max 2500 V 0 .. ± 3750 V 4 mA R M min R M max 0 0 170 90 Ω Ω
Features
•Closed loop (compensated) voltage
transducer using the Hall effect
•Insulated plastic case recognized
according to UL 94-V0
Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
50 mA 2500 V / 50 mA ± 15 V 10 + IS mA 9 kV
•Primary resistor R 1 incorporated into
the housing.
Advantages
•Excellent accuracy •Very good linearity •Low thermal drift •High immunity to external
interference.
Accuracy - Dynamic performance data
XG
ε
L
Overall Accuracy @ VPN , TA = 25°C Linearity Offset current @ IP = 0, TA = 25°C Thermal drift of IO Response time @ 90 % of VP max
± 0.7 < 0.1 Typ Max ± 0.2 ± 0.3
% % mA mA µs
Applications
•AC variable speed drives and servo
motor drives
IO IOT tr
0°C .. + 70°C
± 0.2 170
•Static converters for DC motor drives •Uninterruptible Power Supplies
(UPS)
General data
TA TS N P R1 RS m Ambient operating temperature Ambient storage temperature Turns ratio Total primary power loss Primary resistance @ TA = 25°C Secondary coil resistance @ TA = 70°C Mass Standards 1) 0 .. + 70 - 25 .. + 85 25000 : 2000 10 625 60 850 EN 50178 °C °C W kΩ Ω g
•Power supplies for welding
applications.
Note :
1)
A list of corresponding tests is available
981102/2
LEM Components
w w w .lem.com
Dimensions LV 100-2500
Front view
(in mm. 1 mm = 0.0394 inch)
Left view
Secondary terminals
Terminal + : supply voltage + 15 V Terminal M : measure Terminal - : supply voltage - 15 V Terminal : ground or earth
Connection
Top view Mechanical characteristics
•General tolerance •Fastening •Connection of primary •Connection of secondary •Connection to the ground •Fastening torque
± 0.3 mm 2 holes ∅ 6.5 mm M5 threaded studs Faston 6.3 x 0.8 mm M5 threaded stud 2.2 Nm or 1.62 Lb. -Ft.
Remarks
•IS is positive when VP is applied on terminal +HT. •The primary circuit of the transducer must be linked to the
connections where the voltage has to be measured.
•This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...), please contact us.