FNW700R64

FNW700R64

  • 厂商:

    LINEAGEPOWER

  • 封装:

  • 描述:

    FNW700R64 - 36 - 75 Vdc Input; 28Vdc Output; 700W Output - Lineage Power Corporation

  • 数据手册
  • 价格&库存
FNW700R64 数据手册
Data Sheet September 6, 2008 FNW700R Series Power Modules; DC-DC Converters 36-75Vdc Input; 28Vdc, 700W Output Features High power density: 127 W/in3 Industry standard pin-out Low output ripple and noise Industry standard Full brick footprint 116.6mm x 60.7mm x 12.7mm (4.6” x 2.4” x 0.5”) Remote Sense 2:1 input voltage range Applications RF Power Amplifier Wireless Networks Switching Networks Single tightly regulated main output Constant switching frequency Latch after fault shutdown Over temperature protection auto restart Loosely regulated auxiliary output Power good signal Output voltage adjustment trim (+10%/-40%) Options Output OCP/OVP auto restart Shorter pins Unthreaded heatsink holes Wide operating case temperature range (-40°C to 100°C) CE mark meets 73/23/EEC and 93/68/EEC directives§ UL60950-1/CSA† C22.2 No. 60950-1-03 Certified ‡ (CCSAUS) and VDE 0805:2001-12 (EN60950-1) Licensed ISO** 9001 and ISO 14001 certified manufacturing facilities Description The FNW700R series of dc-dc converters are a new generation of isolated DC/DC power modules providing up to 700W output power in an industry standard full size brick footprint, which makes it an ideal choice for high voltage and high power applications. Threaded-through holes are provided to allow easy mounting or addition of a heatsink for high-temperature applications. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections § † This product is intended for integration into end use equipment only CSA is a registered trademark of Canadian Standards Association. ‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards Document No: DS07-003 ver 1.45 PDF name: fnw700r.ds.pdf : Data Sheet September 6, 2008 FNW700R Power Modules; DC-DC Converters 36 – 75 Vdc Input; 28Vdc Output; 700W Output Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Input Voltage (Continuous) Operating Ambient Temperature (See Thermal Considerations section) Note: When the operating ambient temperature is within 55C~85C, the application of the module refers to the derating curves of Figure 15 and Figure 16. Device All All Symbol VIN TA Min -0.3 -40 Max 80 85 Unit Vdc °C Operating Case Temperature (See Thermal Considerations section) Storage Temperature I/O Isolation Voltage, input to case Output to case All All All All TC Tstg ⎯ ⎯ -40 -55 ⎯ ⎯ 100 125 1500 500 °C °C Vdc Vdc Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Operating Input Voltage Maximum Input Current (VIN=36V to 75V, IO=IO, max) Inrush Transient Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12μH source impedance; VIN=0V to 75V, IO= IOmax ; see Figure 10) Input Ripple Rejection (120Hz) Device All All All All All 60 Symbol VIN IIN,max It 2 Min 36 Typ 48 Max 75 23 2 40 Unit Vdc Adc As mAp-p dB 2 CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to being an integrated part of complex power architecture. To preserve maximum flexibility, internal fusing is not included. Always use an input line fuse, to achieve maximum safety and system protection. The safety agencies require a fastacting fuse with a maximum rating of 30A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. LINEAGE POWER 2 Data Sheet September 6, 2008 FNW700R Power Modules; DC-DC Converters 36 – 75 Vdc Input; 28Vdc Output; 700W Output Electrical Specifications (continued) Parameter Output Voltage Set-point (VIN=VIN,nom, IO=IO, max, Tc =25°C) Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life) Output Regulation Line (VIN=VIN, min to VIN, max) Load (IO=IO, min to IO, max) Temperature (Tc = -40ºC to +100ºC) Output Ripple and Noise on nominal output (VIN=VIN, nom and IO=IO, min to IO, max) RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) External Capacitance Note: use a minimum 470uF output capacitor. If 0 the ambient temperature is less than -20 C, use more than 3 of recommended minimum capacitors. Output Current Output Current Limit Inception Efficiency 0 VIN=VIN, nom, Tc=25 C IO=IO, max , VO= VO,set Switching Frequency Dynamic Load Response (ΔIO/Δt=1A/10μs; Vin=Vin,nom; Tc=25°C; Tested with a 470 μF aluminum and a 10 µF ceramic capacitor across the load.) Load Change from IO= 50% to 75% of IO,max: Peak Deviation Settling Time (Vo
FNW700R64 价格&库存

很抱歉,暂时无法提供与“FNW700R64”相匹配的价格&库存,您可以联系我们找货

免费人工找货