KE007A0S6R541-SR

KE007A0S6R541-SR

  • 厂商:

    LINEAGEPOWER

  • 封装:

  • 描述:

    KE007A0S6R541-SR - 43.2 - 57.6Vdc Input; 6.5Vdc Output; 7.0A Output Current - Lineage Power Corporat...

  • 数据手册
  • 价格&库存
KE007A0S6R541-SR 数据手册
Data Sheet March 26, 2008 KE007A0S6R5-SR (Sixteenth-Brick) Power Modules: 43.2 – 57.6Vdc Input; 6.5Vdc Output; 7.0A Output Current RoHS Compliant Features Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Compliant to RoHS EU Directive 2002/95/EC with lead solder exemption (non-Z versions) Delivers up to 7A output current High efficiency – 92% at 6.5VOUT, full load Small size and low profile: 33.0 mm x 22.9 mm x 8.5 mm (1.30 in x 0.9 in x 0.335 in) Applications Semiconductor Testing Equipment Industry standard DOSA footprint Surface Mount, Tape and Reel (-SR Suffix) Output voltage adjustment trim Remote On/Off Remote Sense No reverse current during output shutdown Over temperature protection (non-latching) Options Negative Remote On/Off logic Over current/Over temperature/Over voltage protections (latching shutdown) Output overcurrent/overvoltage protection (nonlatching) Wide operating temperature range (-40°C to 85°C) Meets the voltage isolation requirements for ETSI 300-132-2 and complies with and is licensed for Basic Insulation rating per EN60950-1 CE mark meets 73/23/EEC and 93/68/EEC directives§ (PENDING APPROVAL) UL* 60950-1Recognized, CSA† C22.2 No. ‡ 60950-1-03 Certified, and VDE 0805:2001-12 (EN60950-1) Licensed ISO** 9001 and ISO 14001 certified manufacturing facilities Description The KE007 (Sixteenth-brick) series power modules are isolated dc-dc converters that operate over an input voltage range of 43.2 to 57.6Vdc and provide a single precisely regulated output. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. The modules exhibit high efficiency, typical efficiency of 92% for 6.5V/7A output. This open frame modules is available in surface-mount, tape and reeled (-SR) package. * UL is a registered trademark of Underwriters Laboratories, Inc. † ‡ CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards Document No: DS06-118 ver. 1.01 PDF name: ke007_ds.pdf Data Sheet March 26, 2008 KE007A0S6R5-SR (Sixteenth-Brick) Power Modules: 43.2 – 57.6Vdc Input; 6.5Vdc Output; 7.0A Output Current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Input Voltage Continuous Operating Ambient Temperature (see Thermal Considerations section) Storage Temperature I/O Isolation voltage (100% factory Hi-Pot tested) S6R5 S6R5 Tstg -55 125 1500 °C Vdc S6R5 S6R5 VIN TA -0.3 -40 60 85 Vdc °C Device Symbol Min Max Unit ⎯ ⎯ Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Operating Input Voltage Maximum Input Current (VIN= VIN, min to VIN, max, IO=IO, max) Input No Load Current (VIN = VIN, nom, IO = 0, module enabled) Input Stand-by Current (VIN = VIN, nom, module disabled) Inrush Transient Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1μH source impedance; VIN, min to VIN, max, IO= IOmax ; See Test configuration section) Input Ripple Rejection (120Hz) EMC, EN55022 S6R5 It 2 Device S6R5 S6R5 S6R5 Symbol VIN IIN,max IIN,No load Min 43.2 Typ 48 1.7 55 Max 57.6 2.0 Unit Vdc Adc mA S6R5 IIN,stand-by 35 mA 0.1 As 2 S6R5 30 mAp-p S6R5 50 60 100 dB See EMC Considerations section CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. LINEAGE POWER 2 Data Sheet March 26, 2008 KE007A0S6R5-SR (Sixteenth-Brick) Power Modules: 43.2 – 57.6Vdc Input; 6.5Vdc Output; 7.0A Output Current Electrical Specifications (continued) Parameter Output Voltage Set-point (VIN=VIN, min, IO=IO, max, TA=25°C) Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life) Adjustment Range Selected by an external resistor Output Regulation Line (VIN=VIN, min to VIN, max) Load (IO=IO, min to IO, max) Temperature (Tref=TA, min to TA, max) Output Ripple and Noise on nominal output (VIN=VIN, nom ,IO= IO, max , TA=TA, min to TA, max) RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) External Capacitance Output Current Output Current Limit Inception (Hiccup Mode ) (VO= 90% of VO, set) Output Short-Circuit Current (VO≤250mV) ( Hiccup Mode ) Efficiency VIN= VIN, nom, TA=25°C IO=IO, max , VO= VO,set Switching Frequency Dynamic Load Response (dIo/dt=0.1A/μs; VIN = VIN, nom; TA=25°C) Load Change from Io= 50% to 75% or 25% to 50% of Io,max; Peak Deviation Settling Time (Vo
KE007A0S6R541-SR 价格&库存

很抱歉,暂时无法提供与“KE007A0S6R541-SR”相匹配的价格&库存,您可以联系我们找货

免费人工找货