KW010A0A41-SR

KW010A0A41-SR

  • 厂商:

    LINEAGEPOWER

  • 封装:

  • 描述:

    KW010A0A41-SR - 36 - 75Vdc Input; 1.2 to 5.0Vdc Output; 10 to 25A Output current - Lineage Power Cor...

  • 详情介绍
  • 数据手册
  • 价格&库存
KW010A0A41-SR 数据手册
Data Sheet March 26, 2008 KW010/015/020/025 (Sixteenth-Brick) Power Modules: 36 –75Vdc Input; 1.2Vdc to 5.0Vdc Output;10A to 25A Output Current RoHS Compliant Features Compliant to RoHS EU Directive 2002/95/EC (-Z versions) Compliant to RoHS EU Directive 2002/95/EC with lead solder exemption (non-Z versions) Delivers up to 25A output current 5V(10A), 3.3V(15A), 2.5V(20A), 1.8V-1.2V(25A) High efficiency – 91% at 3.3V full load Small size and low profile: 33.0 mm x 22.9 mm x 8.5 mm (1.30 in x 0.9 in x 0.335 in) Industry standard DOSA footprint -20% to +10% output voltage adjustment trim Remote On/Off Remote Sense No reverse current during output shutdown Over temperature protection (latching) Output overcurrent/overvoltage protection (latching) Wide operating temperature range (-40°C to 85°C) Meets the voltage isolation requirements for ETSI 300-132-2 and complies with and is licensed for Basic Insulation rating per EN60950-1 UL* 60950-1Recognized, CSA† C22.2 No. ‡ 60950-1-03 Certified, and VDE 0805 (IEC60950 rd 3 Edition) Licensed CE mark meets 2006/95/EC directive§ ISO** 9001 and ISO 14001 certified manufacturing facilities Applications Distributed power architectures Wireless networks Access and optical network Equipment Enterprise Networks Latest generation IC’s (DSP, FPGA, ASIC) and Microprocessor powered applications Options Negative Remote On/Off logic Surface Mount (Tape and Reel, -SR Suffix) Over current/Over temperature/Over voltage protections (auto-restart) Shorter lead trim Description The KW (Sixteenth-brick) series power modules are isolated dc-dc converters that operate over a wide input voltage range of 36 to 75Vdc and provide a single precisely regulated output. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. The modules exhibit high efficiency, typical efficiency of 91% for 3.3V/15A. These open frame modules are available either in surface-mount (-SR) or in through-hole (TH) form. * UL is a registered trademark of Underwriters Laboratories, Inc. † CSA is a registered trademark of Canadian Standards Association. ‡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V. § This product is intended for integration into end-use equipment. All of the required procedures of end-use equipment should be followed ** ISO is a registered trademark of the International Organization of Standards Document No: DS04-045 ver. 1.05 PDF name: kw010-015-020-025_ds.pdf Data Sheet March 26, 2008 KW010/015/020/025 Series Power Modules: 36 – 75Vdc Input; 1.2 to 5.0Vdc Output; 10 to 25A Output current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Input Voltage Continuous Transient (100 ms) Operating Ambient Temperature (see Thermal Considerations section) Storage Temperature I/O Isolation voltage (100% Factory Hi-Pot tested) All All Tstg -55 125 1500 °C Vdc All All All VIN VIN,trans TA -0.3 -0.3 -40 80 100 85 Vdc Vdc °C Device Symbol Min Max Unit ⎯ ⎯ Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Operating Input Voltage Maximum Input Current (VIN= VIN, min to VIN, max, IO=IO, max) Input No Load Current (VIN = VIN, nom, IO = 0, module enabled) Input Stand-by Current (VIN = VIN, nom, module disabled) Inrush Transient Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 1μH source impedance; VIN, min to VIN, max, IO= IOmax ; See Test configuration section) Input Ripple Rejection (120Hz) EMC, EN55022 All It 2 Device All All All Symbol VIN IIN,max IIN,No load Min 36 Typ 48 1.7 55 Max 75 2.0 Unit Vdc Adc mA All IIN,stand-by 5 7 mA 0.1 As 2 All 30 mAp-p All 50 60 100 dB See EMC Considerations section CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies require a time-delay fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information. LINEAGE POWER 2 Data Sheet March 26, 2008 KW010/015/020/025 Series Power Modules: 36 – 75Vdc Input; 1.2 to 5.0Vdc Output; 10 to 25A Output current Electrical Specifications (continued) Parameter Output Voltage Set-point (VIN=VIN, min, IO=IO, max, TA=25°C) Device A F G Y M P Output Voltage (Over all operating input voltage, resistive load, and temperature conditions until end of life) Adjustment Range Selected by an external resistor Output Regulation Line (VIN=VIN, min to VIN, max) Load (IO=IO, min to IO, max) Temperature (Tref=TA, min to TA, max) Output Ripple and Noise on nominal output (VIN=VIN, nom ,IO= IO, max , TA=TA, min to TA, max) RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) External Capacitance Rated Output Current A, F, G, Y M, P All A F G Y M P Output Current Limit Inception (Hiccup Mode ) (VO= 90% of VO, set) Output Short-Circuit Current (VO≤250mV) ( Hiccup Mode ) All All CO, max IO, Rated IO, Rated IO, Rated IO, Rated IO, Rated IO, Rated IO, lim IO, s/c ⎯ ⎯ ⎯ ⎯ 0 0 0 0 0 0 0 115 ⎯ 25 75 33 100 ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ 120 3 ⎯ ⎯ ⎯ ⎯ 10,000 10 15 20 25 25 25 125 ⎯ mVrms mVpk-pk mVrms mVpk-pk μF Adc Adc Adc Adc Adc Adc %IO, Rated Arms A, F, G Y, M, P A, F, G Y, M, P All ⎯ ⎯ ⎯ ⎯ ⎯ ⎯ 0.1 2 0.1 2 1.0 % VO, set mV % VO, set mV % VO, set All VO,adj -20.0 +10.0 % VO, set All Symbol VO, set VO, set VO, set VO, set VO, set VO, set VO Min 4.93 3.25 2.46 1.77 1.48 1.18 -3.0 Typ 5.0 3.3 2.5 1.8 1.5 1.2 Max 5.08 3.35 2.54 1.83 1.53 1.22 +3.0 Unit Vdc Vdc Vdc Vdc Vdc Vdc % VO, set LINEAGE POWER 3 Data Sheet March 26, 2008 KW010/015/020/025 Series Power Modules: 36 – 75Vdc Input; 1.2 to 5.0Vdc Output; 10 to 25A Output current Electrical Specifications (continued) Parameter Efficiency VIN= VIN, nom, TA=25°C IO=IO, max , VO= VO,set Device A F G Y M P Switching Frequency Dynamic Load Response (dIo/dt=0.1A/μs; VIN = VIN, nom; TA=25°C) Load Change from Io= 50% to 75% or 25% to 50% of Io,max; Peak Deviation Settling Time (Vo
KW010A0A41-SR
物料型号: - KW010A0A41-SR:48V输入,5.0V输出,10A输出电流,负逻辑远程开关,表面贴装。 - KW015A0F41-SR:48V输入,3.3V输出,15A输出电流,负逻辑远程开关,表面贴装。 - KW025A0Y1-SR:48V输入,1.8V输出,25A输出电流,负逻辑远程开关,表面贴装。 - 等等,具体型号和参数详见订购信息表格。

器件简介: KW系列电源模块是隔离式直流-直流转换器,输入电压范围36至75Vdc,提供单一精确调节的输出电压。输出与输入完全隔离,允许多样的极性配置和接地连接。这些开放式框架模块可提供表面贴装(-SR)或通孔(TH)形式。

引脚分配: - PIN 1: VIN(+) - PIN 2: On/Off - PIN 3: VIN(-) - PIN 4: Vo(-) - PIN 5: Sense(-) - PIN 6: Trim - PIN 7: Sense(+) - PIN 8: Vo(+)

参数特性: - 工作输入电压:36Vdc至75Vdc - 输出电压:1.2Vdc至5.0Vdc - 输出电流:10A至25A - 效率:典型效率为91%(3.3V/15A) - 隔离电压:1500Vdc(100%工厂Hi-Pot测试)

功能详解: - 远程开关功能 - 远程感应功能 - 输出电压调整范围:通过外部电阻选择 - 输出过电流/过电压保护(锁定) - 宽工作温度范围:-40°C至85°C

应用信息: 适用于从简单的独立操作到复杂的电源架构集成等多种应用。

封装信息: - 表面贴装(-SR)或通孔(TH)形式 - 符合行业标准的DOSA足迹 - 封装尺寸和公差详见机械轮廓图
KW010A0A41-SR 价格&库存

很抱歉,暂时无法提供与“KW010A0A41-SR”相匹配的价格&库存,您可以联系我们找货

免费人工找货