0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LTPL-P00DMS27

LTPL-P00DMS27

  • 厂商:

    LITEON(光宝)

  • 封装:

    2020

  • 描述:

    LEDWHITEWARM80CRISMD

  • 数据手册
  • 价格&库存
LTPL-P00DMS27 数据手册
Lite-On Technology Corporation OFFICE : 90, Chien I Road, Chung Ho Taipei, Taiwan, R.O.C. TEL : +886-2-2222-6181 ~ 8 FAX:+886-2-2221-0660, +886-2-2221-2780,+886-2-2225-1518 FAX HIGH POWER LED LTPL-P00DMS-27 DATA SHEET LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 1. Description The LTPL (LiteOn Power LED) is a revolutionary, energy efficient and ultra compact new light source, combining the lifetime and reliability advantages of Light Emitting Diodes with the brightness of conventional lighting. It gives you total design freedom and unmatched brightness, creating a new opportunities for solid state lighting to displace conventional lighting technologies. Features Applications High power LED light source Reading lights Long life, up to 100k hours Portable (flashlight, bicycle) Instant light (less than 100 ns) Downlighters/Orientation Low voltage DC operated Decorative/Entertainment Low thermal resistance Bollards/Security/Garden RoHS Compliant Cove/Undershelf/Task Lead free reflow solder compatible Traffic signaling/Beacons/ Rail crossing and Wayside Indoor/Outdoor Commercial Residential Architectural Edge_lit signs (Exit, point of sale) 2. Outline Dimensions Notes 1. All dimensions are in millimeters. 2. Tolerance is ±0.2 mm (.008") unless otherwise noted. Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 1 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 3. Rating and Characteristics Absolute Maximum Ratings at Ta=25°C Parameter Symbol Rating Unit Po 0.3 W IF 75 mA IFP 90 mA Reverse Voltage * VR 10 V Junction Temperature Tj 115 °C Thermal Resistance, Junction-Case Rth, J-C 12.16 °C/W Thermal Resistance, Junction-Ambient Rth, J-A 19.66 °C/W Operating Temperature Range Topr -40 - 85 °C Storage Temperature Range Tstg -40 - 100 °C Power Dissipation 1 Forward Current * 1, *2 Forward Pulse Current * 1 Notes 1. The value are based on one die performance. 2. The pulse mode condition is 1/10 duty cycle with 100 msec pulse width. 3. Forbid to operating at reverse voltage condition for long. Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 2 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Electro-Optical Characteristics at Ta=25°C Parameter 1 Forward Voltage* 2 Luminous Flux* 1 Reverse Current* Symbol MIN. TYP. MAX. Test Condition VF 2.7 3.27 3.8 IF= 75mA* ΦV 23.5 45 61.2 100 VR = 10V* IR Color Rendering Index 2 View Angle* 2 Chromaticity Coordinates* Unit 1 V IF = 75mA* 1 lm 1 µA *1 CRI 80 IF = 75mA 2θ1/2 120 IF = 75mA* Cx 0.459 Cy 0.410 1 ° 1 IF = 75mA* 1 IF = 75mA* Notes 1. For each die. 2. When all LED dies are operated simultaneously. 3. Luminous flux is the total luminous flux output as measured with an integrating sphere. 4. The chromaticity coordinates (x, y) is derived from the CIE 1931 chromaticity diagram. 5. Luminous flux measurement allowance is ±7.5%. 6. Forward voltage measurement allowance is ±0.1V. 7. Color coordinates (x, y) measurement allowance is ±0.005. 8. Color rendering (Ra) measurement allowance is ±2. Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 3 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Typical Electrical / Optical Characteristics Curves 1.0 0.9 0.8 Relative Intensity 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 400 450 500 550 600 650 700 750 Wavelength (nm) Fig 1. Relative Spectrum of Emission 0° 100% 90% 30° Relative Intensity (%) 80% 70% 60% 60° 50% 40% 30% 20% 10% 0% 90° 60 30° 0° 50 100 Fig 2. Radiation Characteristics Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 4 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 200 180 Forward Current I F (mA) Forward current IF (mA) 200 150 100 160 140 120 100 Rth,J-A=40℃/W 80 Rth,J-A=30℃/W 60 Rth,J-A=20℃/W 40 Rth,J-A=10℃/W 20 50 0 60 80 100 120 Ambient Temperature (°C) 0 2.5 2.6 2.7 2.8 2.9 3 3.1 3.2 Forward Voltage VF (V) Fig 4. Forward Current Derating Curve Fig 3. Forward Current 120% 0.48 0.47 Chromaticity Coordinates x, y Relative Luminous Flux (%) 100% 80% 60% 40% 20% 0.46 X 0.45 0.44 0.43 Y 0.42 0.41 0.40 0% 0 50 100 150 200 0 50 100 150 200 Forward Current IF (mA) Forward Current IF (mA) Fig 6. Chromaticity Coordinate Shift Fig 5. Relative Luminous Flux Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 5 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 4. Category Code Table P K S1 Chromaticity Coordinate Categories Code x y Code x y Code x y M1 0.4625 0.4113 M2 0.4520 0.3927 M3 0.4546 0.4095 (2700) 0.4729 0.4299 (2700) 0.4625 0.4113 (2700) 0.4646 0.4280 0.4813 0.4319 0.4703 0.4132 0.4729 0.4299 0.4703 0.4132 0.4593 0.3944 0.4625 0.4113 M4 0.4446 0.3910 M5 0.4468 0.4077 M6 0.4373 0.3893 (2700) 0.4546 0.4095 (2700) 0.4562 0.4260 (2700) 0.4468 0.4077 0.4625 0.4113 0.4646 0.4280 0.4546 0.4095 0.4520 0.3927 0.4546 0.4095 0.4446 0.3910 P1 0.4386 0.4048 P2 0.4298 0.3867 P3 0.4305 0.4019 (3000) 0.4474 0.4228 (3000) 0.4386 0.4048 (3000) 0.4387 0.4197 0.4562 0.4260 0.4468 0.4077 0.4474 0.4228 0.4468 0.4077 0.4373 0.3893 0.4386 0.4048 P4 0.4222 0.3840 P5 0.4223 0.3990 P6 0.4147 0.3814 (3000) 0.4305 0.4019 (3000) 0.4299 0.4165 (3000) 0.4223 0.3990 0.4386 0.4048 0.4387 0.4197 0.4305 0.4019 0.4298 0.3867 0.4305 0.4019 0.4222 0.3840 Luminous Flux Categories CCT Bin Grade Spec Code Min Max M: 2550-2850 K P0 23.5 30.6 P: 2850-3200 K Q0 30.6 39.8 R0 39.8 51.7 S0 51.7 61.2 Notes 1. The value is all dies operated performance with forward current 75mA per die. 2. Luminous flux measurement allowance is ± 7%. Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 6 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 0.44 2550K 2850K 0.43 3200K 3200K 0.42 0.41 CY P5 P5 P3 P3 0.40 P6 P6 0.39 P4 P4 P2 P2 M5 P1 P1 M4 M6 M1 M3 M2 0.38 0.37 0.40 0.41 0.42 0.43 0.44 0.45 0.46 0.47 0.48 0.49 CX Notes 1. The value is all dies operated performance. 2. The chromaticity coordinates (x, y) is derived from the CIE 1931 chromaticity diagram. 3. IS CAS140B is for the luminous flux (lm) and the CIE1931 chromaticity coordinates (x, y) testing. The chromaticity coordinates (x, y) guarantee should be added ± 0.005 tolerance. Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 7 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 5. Reflow Soldering Characteristics tP TP Temperature Ramp-up TL tL TSmax TSmin Preheat, tS 25° C to Peak, t Ramp-dow n Time Profile Feature Lead Free Assembly Average Ramp-Up Rate (TSmax to TP) 3°C / second max Preheat Temperature Min (TSmin) 150°C Preheat Temperature Max (TSmax) 200°C Preheat Time (tSmin to tSmax) 60 – 180 seconds Time Maintained Above Temperature (TL) 217°C Time Maintained Above Time (tL) 60 – 150 seconds Peak / Classification Temperature (TP) 260°C Time Within 5°C of Actual Peak Temperature (t P) 5 seconds Ramp – Down Rate 6°C / second max Time 25°C to Peak Temperature 8 minutes max Notes: 1. The LEDs can be soldered using the reflow soldering or hand soldering method. The recommended hand soldering condition is 350°C max. and 2secs ma x. for one time only. 2. All temperatures refer to topside of the package, measured on the package body surface. 3. The soldering condition referring to J-STD-020B. If the LEDs were unpacked more than 24hrs, baking the LEDs at 60℃ for 60 mins before soldering process. 4. The soldering profile could be further referred to different soldering grease material characteristic. The grease vendor will provide this information. 5. A rapid-rate process is not recommended for the LEDs cooling down from the peak temperature. 6. Although the recommended reflow conditions are specified above, the reflow or hand soldering condition at the lowest possible temperature is desirable for the LEDs. 7. LiteOn cannot make a guarantee on the LEDs which have been already assembled using the dip soldering method Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 8 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 6. Recommend Solder Pad Solder Pad Design Notes: 1. All dimensions are in millimeters 2. The circle metallization board and lead contact pad is electrically isolated. Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 9 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 7. Package Dimensions of Tape and Reel Notes: 1. Empty component pockets sealed with top cover tape. 2. 1000 pieces per 7 inch real. (Min. packing quantities are 500 pieces for remainders) 3. The maximum number of consecutive missing LED is two. 4. In accordance with EIA-481-1-L23 specifications. Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 10 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 8. Cautions Application The LEDs described here are intended to be used for ordinary electronic equipment (such as office equipment, communication equipment and household applications).Consult Liteon’s Sales in advance for information on applications in which exceptional reliability is required, particularly when the failure or malfunction of the LEDs may directly jeopardize life or health (such as in aviation, transportation, traffic control equipment, medical and life support systems and safety devices). Storage This product is qualified as Moisture Sensitive Level 4 per JEDEC J-STD-020 Precaution when handing this moisture sensitive product is important to ensure the reliability of the product. The package is sealed: o The LEDs should be stored at 30 C or less and 90%RH or less. And the LEDs are limited to use within one year, while the LEDs is packed in moisture-proof package with the desiccants inside. The package is opened: o The LEDs should be stored at 30 C or less and 60%RH or less. Moreover, the LEDs are limited to solder process within 72hrs. If the Humidity Indicator shows the pink color in 10% even higher or exceed the storage limiting time since opened, that we recommended to be with workable desiccants in original package. Drive Method An LED is a current-operated device. In order to ensure intensity uniformity on multiple LEDs connected in parallel in an application, it is recommended that a current limiting resistor be incorporated in the drive circuit, in series with each LED as shown in Circuit A below. LED Circuit model A LED Circuit model B (A) Recommended circuit. (B) The brightness of each LED might appear different due to the differences in the I-V characteristics of those LEDs. Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 11 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Reliability Test Test Item Test Condition Test Point Number of Damaged Resistance to Soldering Heat Tsld = 260 C, 10 sec o 1 Time 0 / 22 Solderability Tsld = 245±5 C, 3 sec 1 Time 0 / 22 High Temperature Operating Life 85 C, IF = 90mA/Die 1000 Hours 0 / 22 High Temperature and High Humidity Life 85 C / 85%RH, IF = 90mA/Die 1000 Hours 0 / 22 Temperature Cycle -40 C / 100 C, 15 min dwell, < 5 min transfer 200 Cycles 0 / 22 Thermal Shock -40 C / 100 C, 30 min dwell, < 20 sec transfer 200 Cycles 0 / 22 High Temperature Storage Ta = 100 C o 1000 Hours 0 / 22 Low Temperature Storage Ta = -40 C o 1000 Hours 0 / 22 o o o o o o o Criteria for Judging the Damage Criteria for Judgment Item Symbol Test Condition Min. Forward Voltage Vf IF = 75mA/Die Luminous Intensity Lm IF = 75mA/Die Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Max. U.S.L. x 1.1 L.S.L. x 0.7 Page: 12 of 13 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only ESD (Electrostatic Discharge) Static Electricity or power surge will damage the LED. Suggestions to prevent ESD damage: Use a conductive wrist band or anti-electrostatic glove when handling these LEDs. All devices, equipment, and machinery must be properly grounded. Work tables, storage racks, etc. should be properly grounded. Use ion blower to neutralize the static charge which might have built up on surface of the LED’s plastic lens as a result of friction between LEDs during storage and handling. ESD-damaged LEDs will exhibit abnormal characteristics such as high reverse leakage current, low forward voltage, or “no light up” at low currents. To verify for ESD damage, check for “light up” and VF of the suspect LEDs at low currents. The VF of “good” LEDs should be >2.0V@0.1mA for InGaN product. Suggested Checking List Static-Safe Workstation & Work Areas 1. Static-safe working stations or work-areas have ESD signs. 2. All surfaces and objects at all static-safe workstation and within 1 ft measure less than 100V. 3. All ionizer activated, positioned towards the units. 4. Each work surface mats grounding is good. Personnel Grounding 1. Every person (including visitors) handling ESD sensitive (ESDS) items wear wrist strap, heel strap or conductive shoes with conductive flooring. 2. If conductive footwear used, conductive flooring also present. 3. Garments, hairs or anything closer than 1 ft to ESD items measure less than 100V. 4. The wrist strap or heel strap/conductive shoes are checked daily and result recorded. 5. All wrist strap or heel strap checkers calibration up to date. Device Handling 1. Each ESDS items identified by EIA-471 labels on item or packaging.. 2. No static charge generators (e.g. plastics) inside shielding containers with ESDS items. 3. All flexible conductive and dissipative package materials are inspected before reuse or recycles Part No.: LTPL-P00DMS-27 BNC-OD-C131/A4 Page: 13 of 13
LTPL-P00DMS27 价格&库存

很抱歉,暂时无法提供与“LTPL-P00DMS27”相匹配的价格&库存,您可以联系我们找货

免费人工找货