SIDACtor ® Protection Thyristors
SLIC Protection
Battrax® Series Positive/Negative - Modified DO-214
Description The Battrax® series offers programmable SIDACtor® overvoltage protection devices for SLIC applications. This series is offered in a negative Battrax version and a positive Battrax version. The B1xx0C_ is for a -VREF supply supply. Designed using REF an SCR and a gate diode, the B1xx0C_ Battrax begins to conduct at |-VREF
REF
Features and Benefits Low voltage overshoot Agency Approvals
Agency Agency File Number E133083
ratings Robust surge current ratings Gate triggered tracking devices
Low on-state voltage Does not degrade with use Fails short circuit when surged in excess of
Pinout Designation
PIN 3 (VREF)
Applicable Global Standards TIA-968-A TIA-968-B ITU K.20/21 Enhanced Level* ITU K.20/21 Basic Level GR 1089 Inter-building*
PIN 3 (+VREF) PIN 1 (Line)
GR 1089 Intra-building IEC 61000-4-5 YD/T 1082 YD/T 993 YD/T 950
PIN 1 (Line)
PIN 2 (Ground)
Schematic Symbol
PIN 2 (Ground) PIN 3 (-VREF) Gate Negative Battrax B1xx0C_ PIN 1 (Line) Positive Battrax B2050C_ PIN 2 (Ground
*A-rated parts require series resistance
Electrical Characteristics
VDRM @lDRM=5μA V min B1100CALRP B1160CALRP B1200CALRP B2050CALRP B1100CCLRP B1160CCLRP B1200CCLRP B2050CCLRP B10A B16A B12A B25A B10C B16C B12C B25C I-VREF I-VREF I-VREF
REF
Part Number
Marking
VS @100V/μs V max I-VREF I-VREF I-VREF
REF
IH mA min 100 160 200 5 100 160 200 5
IS mA max 100 100 100 50 100 100 100 50
IT A max 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
VT @IT=2.2 Amps V max 4 4 4 4 4 4 4 4
Capacitance* pF Min 30 30 30 20 30 30 30 20 Max 200 200 200 200 200 200 200 200
I-VREF I-VREF I-VREF
REF
I-VREF I-VREF I-VREF
REF
Notes: - Absolute maximum ratings measured at TA= 25ºC (unless otherwise noted). - Devices are uni-directional - All electrical characteristics shown are defined from Tip (pin 1) to Ground (pin 2), and Ring (pin 1) to Ground (pin 2) © 2011 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to www.littelfuse.com for current information. 114
- VREF Max Value for the negative Battrax is -200 V. - VREF Max Value for the positive Battrax is 110 V. * Off-state capacitance (CO) is measured across pins 1 & 2 at 1 MHz with a 2V bias.
Revised: February 22, 2011
SIDACtor ® Protection Thyristors
SLIC Protection
Surge Ratings
IPP Series 0.2x310 0.5x700 2
1
2x10 2x10 2
1
8x20 1.2x50 2
1
10x160 10x160 2
1
10x560 1 10x560 2 A min 50 150
5x320 1 9x720 2 A min 75 200
10x360 1 10x360 2 A min 75 175
10x1000 1 10x1000 2 A min 45 100
5x310 1 10x700 2 A min 75 200
ITSM 50/60 Hz A min 20 50
di/dt A/μs max 500 500
1: Current waveform in μs 2: Voltage waveform in μs
A min 20 50
A min 150 500
A min 150 400
A min 90 200
A C
Notes:
1 Current waveform in μs 2 Voltage waveform in μs
- Peak pulse current rating (IPP) is repetitive and guaranteed for the life of the product. - IPP rating assumes VREF PP - The device must initially be in thermal equilibrium with -40°C < TJ <
Thermal Considerations
Package Modified DO-214AA
PIN 3 (VREF)
Symbol TJ TS
Parameter Operating Junction Temperature Range Storage Temperature Range Thermal Resistance: Junction to Ambient
Value
Unit °C °C
PIN 1 (Line)
PIN 2 (Ground)
R0JA
85
°C/W
V-I Characteristics - Negative Battrax
+I
V-I Characteristics - Positive Battrax
+I IT IGT IH
VS VDRM -V
VT +V
IDRM -V VT VDRM VS +V
IDRM IH IGT IT -I
-I
Normalized VS Change vs. Junction Temperature
Normalized DC Holding Current vs. Case Temperature
2.0
14
Percent of VS Change – %
10
IH (TC = 25ºC)
12
1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4
-40 -20 0 20 40 60 80 100 120 140 160
6 4 2 0 -4 -6 -8 -40 -20 0
IH
8
25 °C
25°C
20 40 60 80 100 120 140 160
Junction Temperature (TJ) – °C
© 2011 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to www.littelfuse.com for current information. 115 Revised: February 22, 2011
Ratio of
Case Temperature (TC) - ºC
SIDACtor ® Protection Thyristors
SLIC Protection
tr x td Pulse Waveform
tr = r ise time to peak value td = decay time to half value
Environmental Specifications
High Temp Voltage Blocking 80% Rated VREF Max. (VDC Peak 1040) JEDEC, JESD22-A-101 cycles. MIL-STD-750 (Method 1051) EIA/JEDEC, JESD22-A104 52 VDC JEDEC, JESD22-A-101 JEDEC, JESD22-A-101 -65°C, 1008 hrs. 10 cycles. MIL-STD-750 (Method 1056) JEDEC, JESD22-A-106 JEDEC, JESD22-A-102
IPP – Peak Pulse Current – %IPP
100
Peak Value
Waveform = tr x td
Temp Cycling Biased Temp & Humidity High Temp Storage Low Temp Storage
50
Half Value
0 0 tr td t – Time (μs)
Thermal Shock Autoclave (Pressure Cooker Test) Resistance to Solder Heat Moisture Sensitivity Level
Physical Specifications
Lead Material Terminal Finish Body Material Copper Alloy 100% Matte-Tin Plated UL recognized epoxy meeting flammability classification 94V-0
Soldering Parameters
Reflow Condition
- Temperature Min (Ts(min))
Pb-Free assembly (see Fig. 1)
Figure 1
Pre Heat
- Temperature Max (Ts(max)) - Time (Min to Max) (ts)
TP
Ramp-up
tP
Critical Zone TL to TP
60-180 secs.
TS(max) to TL - Ramp-up Rate Reflow
- Temperature (TL) (Liquidus) - Temperature (tL)
3°C/sec. Max. 60-150 secs.
Temperature
Average ramp up rate (Liquidus Temp (TL) to peak)
3°C/sec. Max.
TL TS(max)
Preheat
tL
Ramp-down
TS(min)
tS
Peak Temp (TP) Time within 5°C of actual Peak Temp (tp) Ramp-down Rate Time 25°C to Peak Temp (TP) Do not exceed 30 secs. Max. 6°C/sec. Max. 8 min. Max.
25 time to peak temperature (t 25ºC to peak)
Time
Part Numbering
Bx xx 0 C x L RP
TYPE
B1: Negative Battrax SIDACtor B2: Positive Battrax SIDACtor
Part Marking
REEL PACK RoHS COMPLIANT IPP RATING PACKAGE TYPE
XXXX XXXXX
Part Number Code
(Refer to Electrical Characteristics Table)
Date Code
HOLDING CURRENT
05: 5 mA 16: 160 mA 10: 100 mA 20: 200 mA
CONSTRUCTION VARIABLE
© 2011 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to www.littelfuse.com for current information.
116 Revised: February 22, 2011
SIDACtor ® Protection Thyristors
SLIC Protection
Dimensions — Modified DO-214AA
B D M N PIN 3
P
Dimensions A B C D E F G H K M N P
Inches Min 0.130 0.201 0.077 0.159 0.030 0.075 0.002 0.077 0.006 0.022 0.027 0.052 Max 0.156 0.220 0.087 0.181 0.063 0.096 0.008 0.104 0.016 0.028 0.033 0.058
Millimeters Min 3.30 5.10 1.95 4.05 0.75 1.90 0.05 1.95 0.15 0.56 0.69 1.32 Max 3.95 5.60 2.20 4.60 1.60 2.45 0.20 2.65 0.41 0.71 0.84 1.47
AC
PIN 1 PIN 2 H E 0.079 (2.0) 0.079 (2.0) J 0.079 (2.0) 0.040 (1.0) 0.110 (2.8)
0.030 (0.76)
F
K
G
Dimensions are in inches (and millimeters).
Pad Outline (MM)
Packing Options
Package Type C Description Modified DO-214AA 3-leaded Tape and Reel Pack Quantity 2500 Added Suffix RP
Industry Standard
EIA-481-D
Tape and Reel Specification — Modified DO-214AA
0.157 (4.0)
0.472 (12.0)
Pin 2
0.360 (9.2)
0.315 (8.0)
Pin 1 12.99 (330.0)
Pin 3
Dimensions are in inches (and millimeters).
0.512 (13.0) Arbor Hole Dia.
Dimensions are in inches (and millimeters).
0.49 (12.4)
Direction of Feed
© 2011 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to www.littelfuse.com for current information.
117 Revised: February 22, 2011