Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Lxx04xx & Qxx04xx Series
Description
®
4 Amp bi-directional solid state switch series is designed for AC switching and phase control applications such as motor speed and temperature modulation controls, lighting controls, and static switching relays. Sensitive type devices guarantee gate control in Quadrants I & IV needed for digital control circuitry. Standard type devices normally operate in Quadrants I & III triggered from AC line. Features & Benefits contact bounce that create voltage transients junctions
Agency
®
Agency Approval
Agency File Number
1000 V 55 A
Value 4 400 to 1000 3 to 25 Unit A V mA
from reaction of switching events generation, depending on activation point of sine wave activation pulse in each half-cycle
Main Features
Symbol IT(RMS) VDRM /VRRM IGT (Q1)
“L-Package” is UL recognized for 2500Vrms eliminates arcing or Applications
Schematic Symbol
Typical applications are AC solid-state switches, power tools, home/brown goods and white goods appliances.
MT2
MT1
Sensitive gate Triacs can be directly driven by microprocessor or popular opto-couplers/isolators. Internally constructed isolated packages are offered for ease of heat sinking with highest isolation voltage.
G
Absolute Maximum Ratings — Sensitive Triacs (4 Quadrants)
Symbol IT(RMS) ITSM I2t di/dt IGTM PG(AV) Tstg TJ
Note: xx = voltage, y = sensitivity ©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 51
Parameter RMS on-state current (full sine wave) Non repetitive surge peak on-state current (full cycle, TJ initial = 25°C) I2t Value for fusing Critical rate of rise of on-state current (IG = 50mA with 0.1μs rise time) Peak gate trigger current Average gate power dissipation Storage temperature range Operating junction temperature range Lxx04Ly / Lxx04Dy Lxx04Ry / Lxx04Vy f = 50 Hz f = 60 Hz tp = 8.3 ms f = 120 Hz tp 10 μs TJ = 110°C TJ = 110°C TJ = 110°C TC = 85°C TC = 75°C t = 20 ms t = 16.7 ms
Value 4 33 40 6.6 50 1.2 0.3 -40 to 150 -40 to 110
Unit A A A2 s A/μs A W °C °C
Lxx04xx & Qxx04xx Series
Revised: July 29, 2010 09:54 AM
4.0A TRIACs
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Absolute Maximum Ratings — Standard Triacs
Symbol RMS on-state current (full sine wave) Non repetitive surge peak on-state current (full cycle, TJ initial = 25°C) I2t Value for fusing Critical rate of rise of on-state current (IG = 50mA with 0.1μs rise time) Peak gate trigger current Average gate power dissipation Storage temperature range Operating junction temperature range Parameter Qxx04Ly / Qxx04Dy Qxx04Ry / Qxx04Vy ITSM I2t di/dt IGTM PG(AV) Tstg TJ
Note: xx = voltage, y = sensitivity
Value TC TC = 85°C t = 20 ms t = 16.7 ms 46 55 12.5 TJ = 125°C TJ = 125°C TJ = 125°C 50 1.2 0.3 -40 to 150 -40 to 125
Unit
IT(RMS)
4
A
f = 50 Hz f = 60 Hz
A A2 s A/μs A W °C °C
tp = 8.3 ms f = 120 Hz tp ≤ 10 μs; IGT IGTM
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — Sensitive Triac (4 Quadrants)
Symbol IGT VGT VGD IH dv/dt (dv/dt)c tgt VD = VDRM RL = 3.3 k TJ = 110°C IT = 100mA VD = VDRM Gate Open TJ = 100°C (di/dt)c = 2.16 A/ms TJ = 110°C IG = 2 x IGT PW = 15μs IT = 5.6 A(pk) 400V 600V Test Conditions Quadrant MAX. MAX. MIN. MAX. TYP . TYP . TYP . 5 25 15 0.5 2.8 10 25 15 1 3.0 Lxx04x3 3 3 Lxx04x5 5 5 1.3 0.2 10 30 20 1 3.0 15 35 25 1 3.2 Lxx04x6 5 10 Lxx04x8 10 20 Unit mA V V mA V/μs V/μs μs
VD = 12V RL = 60
IV ALL ALL
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — Standard Triac
Symbol IGT VGT VGD IH VD = VDRM RL = 3.3 k IT = 200mA 400V dv/dt VD = VDRM Gate Open TJ = 125°C 600V 800V VD = VDRM Gate Open TJ = 100°C (dv/dt)c tgt (di/dt)c = 2.16 A/ms TJ = 125°C IG = 2 x IGT PW = 15μs IT = 5.6 A(pk) 1000V TYP . TYP . 2 2.5 MIN. TJ = 125°C ALL Test Conditions Quadrant MAX. VD = 12V RL = 60 IV TYP . MAX. MIN. MAX. Qxx04x3 10 25 1.3 0.2 20 40 30 Qxx04x4 25 50 1.3 0.2 30 75 50 40 50 2 3.0 V/μs μs V/μs Unit mA V V mA
Note: xx = voltage, x = package
Lxx04xx & Qxx04xx Series
52 Revised: July 29, 2010 09:54 AM
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Static Characteristics (TJ = 25°C, unless otherwise specified)
Symbol VTM ITM = 5.6A tp = 380 μs Lxx04xy IDRM IRRM VDRM = VRRM MAX. Qxx04xy Test Conditions MAX. TJ = 25°C TJ = 110°C TJ = 25°C TJ = 125°C TJ = 100°C 400-600V 400-600V 400-1000V 400-800V 1000V Value 1.60 5 200 10 2 mA 3 Unit V μA μA μA
Thermal Resistances
Symbol Parameter L/Qxx04Dy L/Qxx04Ly R
(J-C)
Value 3.5 3.6
Unit
Junction to case (AC) L/Qxx04Ry L/Qxx04Vy L/Qxx04Ly 3.6 6.0 50 45 70
°C/W
R
(J-A)
Junction to ambient
L/Qxx04Ry L/Qxx04Vy
°C/W
Note: xx = voltage, x = package, y = sensitivity
Figure 1: Definition of Quadrants
Figure 2: Normalized DC Gate Trigger Current for All Quadrants vs. Junction Temperature
4.0
ALL POLARITIES ARE REFERENCED TO MT1 M T2 POSITIVE (Positive Half Cycle)
MT2
(-)
+
MT2
IGT (TJ = 25°C)
MT1
MT1
IGT
IGT GATE
3.0
(+)
IGT GATE
2.0
IGT
+
MT2 IGT GATE
IGT
MT2
(-)
Ratio of
IGT GATE
REF
QII QI QIII QIV
(+)
REF
1.0
0.0
MT1 REF
MT2 NEGATIVE (Negative Half Cycle)
-
MT1 REF
-65
-40
-40
10
35
60
85
110
125
Junction Temperature (TJ)- ºC
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
53 Revised: July 29, 2010 09:54 AM
Lxx04xx & Qxx04xx Series
4.0A TRIACs
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Figure 3: Normalized DC Holding Current vs. Junction Temperature
4.0
Figure 4: Normalized DC Gate Trigger Voltage for All Quadrants vs. Junction Temperature
2.0
VGT (TJ = 25°C)
IH (TJ = 25°C)
3.0
1.5
IH
VGT
2.0
1.0
Ratio of
Ratio of
1.0
0.5
0.0 -65 -40 -40 10 35 60 85 110 125
0.0 -65 -40 -40 10 35 60 85 110 125
Junction Temperature (TJ)- ºC
Junction Temperature (TJ)- ºC
Figure 5: Power Dissipation (Typical) vs. RMS On-State Current
4.0
Figure 6: Maximum Allowable Case Temperature vs. On-State Current
110 105 CURRENT WAVE FORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360° CASE TEMPERATURE: Measured as shown on Dimensional Drawing
Average On-State Power Dissipation (PD(AV)) - Watts
3.0
LOAD: Resistive or Inductive CONDUCTION ANGLE: 360°
Maximum Allowable Case Temperature (TC) - °C
CURRENT WAVE FORM: Sinusoidal
100 95 90 85 80 75 70 65
Lxx04Ly Lxx04Dy
2.0
Lxx04Vyz Lxx04Ry LXX04Vy
1.0
0.0 0.0 1.0 2.0 3.0 4.0 5.0
60 0 1 2 3 4 5 6
RMS On-State Current (IT(RMS)) - Amps
RMS On-State Current (IT(RMS)) - Amps
Figure 7: Maximum Allowable Case Temperature vs. On-State Current
110 105 CURRENT WAVE FORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360° CASE TEMPERATURE: Measured as shown on Dimensional Drawing
Figure 8: Maximum Allowable Ambient Temperature vs. On-State Current
120 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360° FREE AIR RATING – NO HEATSINK
Maximum Allowable Ambient Temperature (TA) - °C
Maximum Allowable Case Temperature (TC) - °C
100 95 90 85 80 75 70 65 60 0 1 2
100
Lxx04Ly Lxx04Dy
80 Qxx04Ly Qxx04Ry 60 L/Qxx04Vy 40 Lxx04Ly 20
Lxx04Vyz Lxx04Ry LXX04Vy
3
4
5
6
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
RMS On-State Current (IT(RMS)) - Amps
RMS On-State Current [IT(RMS)] - Amps
Note: xx = voltage, y = sensitivity
Lxx04xx & Qxx04xx Series
54 Revised: July 29, 2010 09:54 AM
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Figure 9: On-State Current vs. On-State Voltage (Typical)
20 18 TJ = 25°C
Positive or Instantaneous On-State Current (IT) - Amps
16 14 12 10 8 6 4 2 0 0.6 0.8 1.0 1.2 1.4 1.6 1.8
Positive or Instantaneous On-State Voltage (VT) - Volts
Figure 10: Surge Peak On-State Current vs. Number of Cycles
100
Peak Surge (Non-repetitive) On-State Current (ITSM) – Amps
Qxx04Ry Qxx04Ly Qxx04Dy Qxx04Vy
Load: Resistive RMS On-State [IT(RMS)]: Max Rated Value at Specific Case Temperature Notes: 1. Gate control may be lost during and immediately following surge current interval. 2. Overload may not be repeated until junction temperature has returned to steady-state rated value.
10
Lxx04Ry Lxx04Ly Lxx04Dy Lxx04Vy
1 1 10 100 1000
Surge Current Duration – Full Cycles
Note: xx = voltage, y = sensitivity
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
55 Revised: July 29, 2010 09:54 AM
Lxx04xx & Qxx04xx Series
4.0A TRIACs
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Soldering Parameters
Reflow Condition
TP
Temperature
- Temperature Min (Ts(min)) Pre Heat - Temperature Max (Ts(max)) - Time (min to max) (ts) Average ramp up rate (Liquidus Temp) (TL) to peak TS(max) to TL - Ramp-up Rate Reflow - Temperature (TL) (Liquidus) - Temperature (tL) 260°C +0/-5 5°C/second max 5°C/second max 217°C
25 time to peak temperature
tP
Ramp-up
150°C 200°C
TL TS(max)
Preheat Preheat
tL
Ramp-do Ramp-down
TS(min)
tS
Time
Peak Temperature (TP) Time within 5°C of actual peak Temperature (tp) Ramp-down Rate Time 25°C to peak Temperature (TP) Do not exceed
5°C/second max 8 minutes Max. 280°C
Physical Specifications
Terminal Finish 100% Matte Tin-plated
Environmental Specifications
Test AC Blocking Specifications and Conditions MIL-STD-750, M-1040, Cond A Applied Peak AC voltage @ 125°C for 1008 hours MIL-STD-750, M-1051, 100 cycles; -40°C to +150°C; 15-min dwell time 1008 hours; 320V - DC: 85°C; 85% rel humidity MIL-STD-750, M-1031, 1008 hours; 150°C 1008 hours; -40°C MIL-STD-750, M-1056 10 cycles; 0°C to 100°C; 5-min dwell time at each temperature; 10 sec (max) transfer time between temperature 168 hours (121°C at 2 ATMs) and 100% R/H MIL-STD-750 Method 2031 ANSI/J-STD-002, category 3, Test A
Body Material
UL recognized epoxy meeting flammability Temperature Cycling
Terminal Material
Copper Alloy Temperature/ Humidity
Design Considerations Careful selection of the correct device for the application’s operating parameters and environment will go a long way toward extending the operating life of the Thyristor. Good design practice should limit the maximum continuous current through the main terminals to 75% of the device rating. Other ways to ensure long life for a power discrete semiconductor are proper heat sinking and selection of voltage ratings for worst case conditions. Overheating, overvoltage (including dv/dt), and surge currents are the main killers of semiconductors. Correct mounting, soldering, and forming of the leads also help protect against component damage.
High Temp Storage Low-Temp Storage
Thermal Shock
Autoclave Resistance to Solder Heat Solderability Lead Bend
Lxx04xx & Qxx04xx Series
56 Revised: July 29, 2010 09:54 AM
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Dimensions — TO-220AB (R-Package) — Non-Isolated Mounting Tab Common with Center Lead
TC MEASURING POINT O E A MT2 B C D 7.01 .276 13.36 .526 P 8.13 .320 AREA (REF.) 0.17 IN2
Dimension A B C D
Inches Min 0.380 0.105 0.230 Max 0.420 0.115 0.250 0.620 0.142 0.147 0.130 0.575 0.035 0.205 0.105 0.060 0.085 0.018 0.178 0.045 0.038 0.024 0.188 0.060 0.048 0.075
Millimeters Min Max 10.67 2.67 5.84 6.35 15.75
F
G L H
R
NOTCH IN GATE LEAD TO ID. NON-ISOLATED TAB
0.110 G H J K 0.540 0.025
3.30 13.72 0.64 5.21 2.41 1.52 2.16 0.46 4.52 1.14 2.41 0.61 4.78 1.52 1.22 2.67 14.61
K J MT1 MT2 GATE
N M
L
be applied to mounting tab
M N O P R
Dimensions — TO-220AB (L-Package) — Isolated Mounting Tab
TC MEASURING POINT O E A P 8.13 .320 AREA (REF.) 0.17 IN2
Dimension A
13.36 .526 7.01 .276
Inches Min 0.380 0.105 0.230 Max 0.420 0.115 0.250 0.620 0.142 0.147 0.130 0.575 0.035 0.205 0.105 0.060 0.085 0.018 0.178 0.045 0.038 0.024 0.188 0.060 0.048 0.075
Millimeters Min Max 10.67 2.67 5.84 6.35 15.75 3.61 3.73 3.30 13.72 0.64 5.21 2.41 1.52 2.16 0.46 4.52 1.14 2.41 0.61 4.78 1.52 1.22 2.67 14.61
B C D
B C D
F
0.110 G 0.540 0.025
R
G L H
H J K
K J MT1 MT2 GATE N M
be applied to mounting tab
L M N O P R
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
57 Revised: July 29, 2010 09:54 AM
Lxx04xx & Qxx04xx Series
4.0A TRIACs
3.61
3.73
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Dimensions — TO-251AA (V-Package) — V-PAK Through Hole
TC MEASURING POINT AREA: 0.040 IN2 5.28 .208
MT2
E D
H J
Dimension A
5.34 .210
Inches Min 0.040 0.235 0.350 0.205 0.255 0.027 Typ 0.044 0.242 0.361 0.208 0.262 0.031 Max 0.050 0.245 0.375 0.213 0.265 0.033 2.21 2.16 0.180 0.020 0.040 0.020 0.047 0.184 0.023 0.044 0.023 0.052 0.044 0.044 0.084 0.46 1.06 0.86 0.86 1.86 4.47 0.46 5.21 6.48 Min 1.02
Millimeters Typ 1.11 6.15 Max 1.27 6.22
A
B C
B
P Q
R
D
S K
5.41 6.66 0.80 2.28 2.34 4.57 0.51 1.01 0.52 1.20 1.00 1.00 2.00 6.73 0.84 2.36 2.41 4.67 0.58 1.12 0.58 1.32 1.11 1.11 2.11
C
G H
MT1 MT2 GATE
G F L
0.087 0.085 0.176 0.018 0.038 0.018 0.042 0.034 0.034 0.074
I J K L P Q R S
I
Dimensions — TO-252AA (D-Package) — D-PAK Surface Mount
MT2 E D TC MEASURING POINT 5.28 .208 6.71 .264
Dimension
6.71 .264
Inches Min
0.040 0.235 0.106 0.205 0.255 0.027
Millimeters Max
0.050 0.245 0.113 0.213 0.265 0.033 2.21 2.16 0.184 4.47 0.46 5.21 6.48 6.65 0.80 2.28 2.33 4.55 0.51 1.02 0.46 0.00 0.53 0° 1.06 0.86 0.51 0.00 0.67 0° 1.20 1.00 5° 1.32 1.11
A 5.34 .210
Typ
0.043 0.243 0.108 0.208 0.262 0.031
Min
1.02
Typ
6.16 2.74
Max
1.27 6.22 2.87 5.41 6.73 0.84 2.36 2.41 4.67 0.58 1.12 0.58 0.10
A B
B
C MT1 MT2 I G
P Q GATE F AREA : 0.040 IN2
1.60 .063 1.80 .071 3 .118 4.60 .181
C D
O
L K M N J H
G H I J K L M N O P Q
0.087 0.085 0.176 0.018 0.038 0.018 0.000 0.021 0° 0.042 0.034 0.020 0.040 0.020 0.000 0.026 0° 0.047
0.023 0.044 0.023 0.004 0.027 5° 0.052 0.044
Lxx04xx & Qxx04xx Series
58 Revised: July 29, 2010 09:54 AM
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
Product Selector
Voltage Part Number 400V Lxx04L3 Lxx04D3 Lxx04R3 Lxx04V3 Lxx04L5 Lxx04D5 Lxx04R5 Lxx04V5 Lxx04L6 Lxx04D6 Lxx04R6 Lxx04V6 Lxx04L8 Lxx04D8 Lxx04R8 Lxx04V8 Qxx04L3 Qxx04D3 Qxx04V3 Qxx04R3 Qxx04L4 Qxx04D4 Qxx04R4 Qxx04V4 X X X X X X X X X X X X X X X X X X X X X X X X 600V X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 800V 1000V I – II – III 3 mA 3 mA 3mA 3 mA 5 mA 5 mA 5mA 5 mA 5 mA 5 mA 5mA 5 mA 10 mA 10 mA 10mA 10 mA 10 mA 10 mA 10 mA 10mA 25 mA 25 mA 25mA 25 mA IV 3 mA 3 mA 3mA 3 mA 5 mA 5 mA 5mA 5 mA 10 mA 10 mA 10mA 10 mA 20 mA 20 mA 20mA 20 mA Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Sensitive Triac Standard Triac Standard Triac Standard Triac Standard Triac Standard Triac Standard Triac Standard Triac Standard Triac TO-220L TO-252 D-PAK TO-220R Gate Sensitivity Quadrants Type Package
TO-220L TO-252 D-PAK TO-220R TO-251 V-PAK TO-220L TO-252 D-PAK TO-220R TO-251 V-PAK TO-220L TO-252 D-PAK TO-220R TO-251 V-PAK TO-220L TO-252 D-PAK TO-251 V-PAK TO-220R TO-220L TO-252 D-PAK TO-220R TO-251 V-PAK
Packing Options
Part Number L/Q004L/Ry/TP L/Qxx04LyTP L/Qxx04DyRP L/Qxx04DyTP L/Qxx04VyTP
Note: xx = Voltage; y = Sensitivity
Marking L/Qxx04L/Ry L/Qxx04Ly L/Qxx04Dy L/Qxx04Dy L/Qxx04Vy
Weight 2.2 g 2.2 g 0.3 g 0.3 g 0.4 g
Packing Mode Bulk Tube
Base Quantity 500 500 (50 per tube) 2500
Tube Pack Tube Pack
750 (75 per tube) 750 (75 per tube)
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
59 Revised: July 29, 2010 09:54 AM
Lxx04xx & Qxx04xx Series
4.0A TRIACs
TO-251 V-PAK
Teccor® brand Thyristors
4 Amp Sensitive & Standard Triacs
TO-252 Embossed Carrier Reel Pack (RP) Specifications Meets all EIA-481-2 Standards
0.157 (4.0) Gate
0.059 DIA (1.5)
MT1
XXXXXX
XXXXXX
XXXXXX
* Cover tape
0.315 (8.0)
MT2
0.512 (13.0) Arbor Hole Dia.
12.99 (330.0)
XXXXXX
XX
XX
XX
0.63 (16.0)
0.524 (13.3)
*
DC
DC
DC
Dimensions are in inches (and millimeters).
0.64 (16.3)
Direction of Feed
Part Numbering System
Q 60 04 L 4 xx
DEVICE TYPE L : Sensitive Triac Q : Standard Triac LEAD FORM DIMENSIONS xx : Lead Form Option
Part Marking System
TO-220 AB (R & L Packages)
TO-251AA & TO-252AA (V and D Packages)
L6004V4
®
VOLTAGE RATING 40 : 400V 60 : 600V 80 : 800V K0 : 1000V
SENSITIVITY & TYPE Sensitive Triac: 3 : 3 mA (QI, II, III, IV) 5 : 5 mA (QI, II, III, IV) 6 : 5 mA (QI, II, III) 10 mA (QIV) 8 : 10 mA (QI, II, III) 20 mA (QIV) Standard Triac: 3 : 10 mA (QI, II, III) 4 : 25 mA (QI, II, III) PACKAGE TYPE L :TO-220 Isolated R :TO-220 Non-Isolated V :TO-251 (V-Pak) D :TO-252 (D-Pak)
yxxxx
®
CURRENT RATING 04 : 4A
Lxx04xx & Qxx04xx Series
60 Revised: July 29, 2010 09:54 AM
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.