Teccor® brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
Qxx25xx & Qxx25xHx Series
Description
®
25 Amp bi-directional solid state switch series is designed for AC switching and phase control applications such as motor speed and temperature modulation controls, lighting controls, and static switching relays.
Alternistor type devices only operate in quadrants I, II, & III and are used in circuits requiring high dv/dt capability. Features & Benefits to 250 A Agency Approval
Agency
®
junctions
Agency File Number TO-220L, TO-218K, TO-218J & Fastpak Packages: E71639
to 1000 V Applications Excellent for AC switching and phase control applications such as heating, lighting, and motor speed controls.
Main Features
Symbol IT(RMS) VDRM /VRRM IGT Value 25 1000 50 to 80 Unit A V mA
Typical applications are AC solid-state switches, industrial power tools, exercise equipment, white goods and commercial appliances. Alternistor Triacs (no snubber required) are used in applications with extremely inductive loads requiring highest commutation performance. Internally constructed isolated packages are offered for ease of heat sinking with highest isolation voltage.
Schematic Symbol
MT2
MT1
G
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
117 Revised: May 10, 2010 09:33 PM
Qxx25xx & Qxx25xHx Series
25 A TRIACs
Standard type devices normally operate in Quadrants I & III triggered from AC line.
Teccor® brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
Absolute Maximum Ratings – Standard Triac
Symbol IT(RMS) Parameter RMS on-state current Qxx25R5 Qxx25N5 Qxx25P5 Qxx25R5 Qxx25N5 ITSM Peak non-repetitive surge current Qxx25P5 Test Conditions TC = 85°C TC = 57°C single half cycle; f = 50Hz; TJ (initial) = 25°C single half cycle; f = 60Hz; TJ (initial) = 25°C single half cycle; f = 50Hz; TJ (initial) = 25°C single half cycle; f = 60Hz; TJ (initial) = 25°C tp = 8.3ms f = 60Hz; TJ =125°C TJ = 125°C TJ = 125°C Qxx25R5 Qxx25N5 Qxx25P5 167 200 A 220 250 166 260 100 2 0.5 -40 to 125 -40 to 125 -25 to 125 A/μs A W °C °C Value 25 Unit A
I 2t di/dt IGTM PG(AV) Tstg TJ
I2t Value for fusing Critical rate-of-rise of on-state current Peak gate current Average gate power dissipation Storage temperature range Operating junction temperature range
Qxx25R5 Qxx25N5 Qxx25P5
A2s
Absolute Maximum Ratings – Alternistor Triac
Symbol Parameter Qxx25LH5 Qxx25L6 Qxx25K6 Qxx25J6 Qxx25RH5 Qxx25NH5 Qxx25R6 Qxx25NH6 Test Conditions TC = 65°C TC = 85°C 25 TC = 95°C A Value Unit
IT(RMS)
RMS on-state current
ITSM
Peak non-repetitive surge current
single half cycle; f = 50Hz; TJ (initial) = 25°C single half cycle; f = 60Hz; TJ (initial) = 25°C tp = 8.3ms f = 60Hz; TJ =125°C TJ = 125°C TJ = 125°C
208 A 250 260 100 2 0.5 -40 to 125 -40 to 125 A2s A/μs A W °C °C
I 2t di/dt IGTM PG(AV) Tstg TJ
Note: xx = voltage
I2t Value for fusing Critical rate-of-rise of on-state current Peak gate current Average gate power dissipation Storage temperature range Operating junction temperature range
Qxx25xx & Qxx25xHx Series
118 Revised: May 10, 2010 09:33 PM
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
Teccor® brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — Standard Triac
Value Symbol Test Conditions Quadrant I – II – III VD = 12V; RL = 60 VGT VGD IH VD = VDRM; RL = 3.3 k IT = 400mA (initial) VD = VDRM; Gate Open; TJ = 125°C VD = VDRM; Gate Open; TJ = 100°C (dv/dt)c tgt (di/dt)c = 13.3 A/ms; TJ = 125°C IG = 2 x IGT; PW = 15μs; IT = 35.4 A 400V 600V 800V 1000V MIN. TYP . 4 ; TJ = 125°C IV I – II – III IV ALL MAX. TYP . MAX. TYP . MIN. MAX. 100 275 225 200 200 5 3 Qxx25R5 Qxx25N5 50 120 1.3 2.5 0.2 50 — 475 400 — V/μs μs Qxx25P5 Unit
IGT
mA
V V mA
dv/dt
MIN.
V/μs
Electrical Characteristics (TJ = 25°C, unless otherwise specified) — Alternistor Triac
Value Symbol Test Conditions Quadrant Qxx25RH5 Qxx25LH5 Qxx25NH5 MAX. MAX. MIN. MAX. 400V 600V 800V 1000V MIN. TYP . 50 575 500 400 — 20 3 50 1.3 0.2 100 600 600 475 400 30 5 V/μs μs Qxx25R6 Qxx25L6 Qxx25NH6 Qxx25K6 Qxx25J6 80 Unit
IGT VGT VGD IH
VD = 12V; RL = 60 VD = VDRM; RL = 3.3 k IT = 400mA (initial) VD = VDRM; Gate Open; TJ = 125°C VD = VDRM; Gate Open; TJ = 100°C ; TJ = 125°C
I – II – III I – II – III I – II – III
mA V V mA
dv/dt
MIN.
V/μs
(dv/dt)c tgt
(di/dt)c = 13.3 A/ms; TJ = 125°C IG = 2 x IGT; PW = 15μs; IT = 35.4 A
Static Characteristics
Value Qxx25R5 Qxx25N5 Qxx25xH5 Qxx25P5 Qxx25x6 Qxx25NH6 MAX. TJ = 25°C IDRM / IRRM VDRM / VRRM TJ = 100°C TJ = 125°C
Note: xx = voltage, x = package ©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 119 Revised: May 10, 2010 09:33 PM Qxx25xx & Qxx25xHx Series
Symbol
Test Conditions
Unit
VTM
IT = 35.4A; tp = 380 μs 600 – 800V 1000V 600 – 800V 1000V 600 – 800V
1.8 10 20
1.4 100 — — — 5000
V
MAX.
500 1000 2000
μA
25 A TRIACs
Teccor® brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
Thermal Resistances
Symbol Parameter Qxx25R5 / Qxx25N5 Qxx25R6 / Qxx25NH6 Qxx25RH5 / Qxx25NH5 R
(J-C)
Value 0.89 1.6 2.0 1.32 45
Unit
Junction to case (AC)
Qxx25P5 Qxx25L6 / Qxx25LH5 Qxx25K6 / Qxx25J6 Qxx25Ry
°C/W
R
(J-A)
Junction to ambient Qxx25L6 / Qxx25LH5 50
°C/W
Note: xx = voltage, y = sensitivity
Figure 1: Normalized DC Gate Trigger Current vs. Junction Temperature
2. 5
Figure 2: Normalized DC Gate Trigger Voltage vs. Junction Temperature
2.0
2.0
Ratio of VGT / VGT(TJ = 25ºC)
Ratio of IGT/IGT(TJ = 25°C)
1.5
1. 5
1.0
1.0
0.5 0. 5
0.0 -40 -15 10 35 60 85 110 125
0.0 -40 -15 10 35 60 85 110 125
Junction Temperature (TJ) -- (°C)
Junction Temperature (TJ) -- (ºC)
Figure 3: Normalized DC Holding Current vs. Junction Temperature
2.0
Figure 4: On-State Current vs. On-State Voltage (Typical)
90
Instantaneous On-state Current (iT) – Amps
TJ = 25°C 80 70 60 50 40 30 20 10 0 Qxx25P5/Qxx25R6 Qxx25L6/Qxx25NH6 Qxx25K6/Qxx25J6 Qxx25RH5/Qxx25LH5 Qxx25NH5
Ratio of IH / IH(TJ = 25ºC)
1. 5
1.0
0. 5
Qxx25R5 Qxx25N5
0.0 -40 -15 10 35 60 85 110 125
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
Junction Temperature (TJ) -- (ºC)
Instantaneous On-state Voltage (vT) – Volts
Qxx25xx & Qxx25xHx Series
120 Revised: May 10, 2010 09:33 PM
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
Teccor® brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
Figure 5: Power Dissipation (Typical) vs. RMS On-State Current
35
Figure 6: Maximum Allowable Case Temperature vs. RMS On-State Current
130
Average On-State Power Dissipation [PD(AV)] -- Watts
30
CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360° Qxx25R5 Qxx25N5
Maximum Allowable Case Temperature (TC) - °C
120 110 100 90 80 Qxx25P5 70 60 50
Qxx25R6 Qxx25NH6 Qxx25RH5 Qxx25NH5
25
Qxx25R5 Qxx25N5 Qxx25K6 Qxx25J6
20
15 Qxx25P5/Qxx25R6 Qxx25L6/Qxx25NH6 Qxx25K6/Qxx25J6 Qxx25RH5/Qxx25LH5 Qxx25NH5
10
5
CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360° 0 5 10 15 20 25 30
0 0 5 10 15 20 25
RMS On-State Current [IT(RMS)] -- Amps
RMS On-State Current [IT(RMS)] - Amps
Figure 7: Maximum Allowable Ambient Temperature vs. RMS On-State Current (TO-220 packages only)
120 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360° FREE AIR RATING
Maximum Allowable Ambient Temperature (TA) --°C
100
80
60
40
20
0 0.0 0.5 1.0 1.5 2.0 2.5
RMS On-State Current [IT(RMS)] -- Amps
Figure 8: Surge Peak On-State Current vs. Number of Cycles
1000
Peak Surge (Non-repetitive) On-state Current (ITSM) – Amps
Qxx25P5/Qxx25R6 Qxx25L6/Qxx25NH6 Qxx25K6/Qxx25J6 Qxx25RH5/Qxx25LH5 Qxx25NH5
SUPPLY FREQUENCY: 60 Hz Sinusoidal LOAD: Resistive RMS On-State Current: [IT(RMS)]: Maximum Rated Value at Specified Case Temperature Notes: 1. Gate control may be lost during and immediately following surge current interval. 2. Overload may not be repeated until junction temperature has returned to steady-state rated value.
100
Qxx25R5 Qxx25N5
10 1 10 100 1000
Surge Current Duration -- Full Cycles
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
121 Revised: May 10, 2010 09:33 PM
Qxx25xx & Qxx25xHx Series
25 A TRIACs
Qxx25L6 Qxx25LH5
Teccor® brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
Soldering Parameters
Reflow Condition - Temperature Min (Ts(min)) Pre Heat - Temperature Max (Ts(max)) - Time (min to max) (ts) Average ramp up rate (Liquidus Temp) (TL) to peak TS(max) to TL - Ramp-up Rate Reflow - Temperature (TL) (Liquidus) - Temperature (tL) Pb – Free assembly
TP
Temperature
Ramp-up
tP
150°C 200°C 60 – 180 secs 5°C/second max 5°C/second max 217°C 60 – 150 seconds 260+0/-5 °C 20 – 40 seconds 5°C/second max 8 minutes Max. 280°C
TL TS(max)
Preheat Preheat
tL
Ramp-do Ramp-down
TS(min) tS
25 time to peak temperature
Time
Peak Temperature (TP) Time within 5°C of actual peak Temperature (tp) Ramp-down Rate Time 25°C to peak Temperature (TP) Do not exceed
Physical Specifications
Terminal Finish 100% Matte Tin-plated UL recognized epoxy meeting flammability classification 94V-0 Copper Alloy
Environmental Specifications
Test High Temperature Voltage Blocking Temperature Cycling Biased Temp & Humidity High Temp. Storage Specifications and Conditions MIL -STD-750: Method 1040, Condition A Rated VRRM, 125°C, 1008 hours MIL -STD-750: Method 1051 -40°C to 125°C, 15-minute dwell, 100 cycles EIA/JEDEC: JESD22-A101 320VDC, 85°C, 85%RH, 1008 hours MIL -STD-750: Method 1031 150°C, 1008 hours -40°C, 1008 hours MIL -STD-750: Method 1056 0°C to 100°C, 5-minute dwell, 10-second transfer, 10 cycles
Body Material
Lead Material
Design Considerations Careful selection of the correct device for the application’s operating parameters and environment will go a long way toward extending the operating life of the Thyristor. Good design practice should limit the maximum continuous current through the main terminals to 75% of the device rating. Other ways to ensure long life for a power discrete semiconductor are proper heat sinking and selection of voltage ratings for worst case conditions. Overheating, overvoltage (including dv/dt), and surge currents are the main killers of semiconductors. Correct mounting, soldering, and forming of the leads also help protect against component damage.
Low-Temp Storage Thermal Shock
Autoclave EIA/JEDEC: JESD22-A102 (Pressure Cooker Test) 121°C, 100%RH, 2atm, 168 hours Resistance to Solder Heat Solderability Lead Bend MIL -STD-750: Method 2031 260°C, 10 seconds ANSI/J-STD-002, Category 3, Test A MIL -STD-750: Method 2036, Condition E
Qxx25xx & Qxx25xHx Series
122 Revised: May 10, 2010 09:33 PM
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
Teccor® brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
Dimensions — TO-220AB (R Package) — Non-isolated Mounting Tab
TC MEASURING POINT O ØE A MT2 B C D 7.01 .276 13.36 .526 P 8.13 .320 AREA (REF.) 0.17 IN2
Dimension A B C D
Inches Min 0.380 0.105 0.230 0.590 0.142 0.110 0.540 0.025 0.195 0.095 0.060 0.085 0.018 0.178 0.045 0.038 Max 0.420 0.115 0.250 0.620 0.147 0.130 0.575 0.035 0.205 0.105 0.075 0.095 0.024 0.188 0.060 0.048
Millimeters Min 9.65 2.67 5.84 14.99 3.61 2.79 13.72 0.64 4.95 2.41 1.52 2.16 0.46 4.52 1.14 0.97 Max 10.67 2.92 6.35 15.75
F
G L H
R
NOTCH IN GATE LEAD TO ID. NON-ISOLATED TAB
F G H
3.30 14.61 0.89 5.21 2.67 1.91 2.41 0.61 4.78 1.52 1.22
K J MT1 MT2 GATE
N M
J
Note: Maximum torque to be applied to mounting tab is 8 in-lbs. (0.904 Nm).
K L M N O P R
Dimensions — TO-220AB (L Package) — Isolated Mounting Tab
TC MEASURING POINT O ØE A P 8.13 .320 AREA (REF.) 0.17 IN2
Dimension A
13.36 .526 7.01 .276
Inches Min 0.380 0.105 0.230 0.590 0.142 0.110 0.540 0.025 0.195 0.095 0.060 0.085 0.018 0.178 0.045 0.038 Max 0.420 0.115 0.250 0.620 0.147 0.130 0.575 0.035 0.205 0.105 0.075 0.095 0.024 0.188 0.060 0.048
Millimeters Min 9.65 2.66 5.85 14.98 3.61 2.80 13.71 0.63 4.95 2.41 1.52 1.78 0.45 4.52 1.14 0.97 Max 10.67 2.92 6.35 15.75 3.73 3.30 14.60 0.89 5.21 2.67 1.91 2.16 0.61 4.78 1.53 1.22
B C D
B C D E
F
F
G L H R
G H J
K J MT1 MT2 GATE
N M
Note: Maximum torque to be applied to mounting tab is 8 in-lbs. (0.904 Nm).
K L M N O P R
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
123 Revised: May 10, 2010 09:33 PM
Qxx25xx & Qxx25xHx Series
25 A TRIACs
E
3.73
Teccor® brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
Dimensions — TO-263 (N Package) — D2Pak Surface Mount
TC MEASURING POINT B MT2 V C E AREA: 0.11 IN2
Dimension
8.41 .331
Inches Min
0.360 0.380 0.178 0.025 0.045 0.060 0.095 0.092 0.018 0.090 0.590 0.035 0.002 0.040
Millimeters Max
0.370 0.420 0.188 0.035 0.060 0.075 0.105 0.102 0.024 0.110 0.625 0.045 0.010 0.070
Min
9.14 9.65 4.52 0.64 1.14 1.52 2.41 2.34 0.46 2.29 14.99 0.89 0.05 1.02
Max
9.40 10.67 4.78 0.89 1.52 1.91 2.67 2.59 0.61 2.79 15.88 1.14 0.25 1.78
A S
7.01 .276
A B C
W
U GATE G D F H K J
D E
8.13 .320
MT1
F G
11.68 .460
2.16 .085
H J
7.01 .276 16.89 .665 8.89 .350
7.01 .276
K S V U
1.40 .055
3.81 .150 2.03 .080 6.60 .260
W
Dimensions — TO-218AC (K Package) — Isolated Mounting Tab
TC Measurement Point B U (diameter) C D
Dimension A
Inches Min 0.810 0.610 0.178 0.055 0.487 0.635 0.022 0.075 0.575 0.211 0.422 0.058 0.045 0.095 0.008 0.008 0.164 0.085 Max 0.835 0.630 0.188 0.070 0.497 0.655 0.029 0.095 0.625 0.219 0.437 0.068 0.055 0.115 0.016 0.016 0.165 0.095
Millimeters Min 20.57 15.49 4.52 1.40 12.37 16.13 0.56 1.91 14.61 5.36 10.72 1.47 1.14 2.41 0.20 0.20 4.10 2.17 Max 21.21 16.00 4.78 1.78 12.62 16.64 0.74 2.41 15.88 5.56 11.10 1.73 1.40 2.92 0.41 0.41 4.20 2.42
A F E W
B C D
Gate P J
E F
H G
MT1 MT2
M
Q
R N
G H J K L M N P Q R U W
K L
Note: Maximum torque to be applied to mounting tab is 8 in-lbs. (0.904 Nm).
Qxx25xx & Qxx25xHx Series
124 Revised: May 10, 2010 09:33 PM
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
Teccor® brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
Dimensions — TO-218X (J Package) — Isolated Mounting Tab
C B U (diameter) D
Dimension A B C D E F G H J K L M N P R S T U V W X Y Z
Inches Min 0.810 0.610 0.178 0.055 0.487 0.635 0.022 0.075 0.575 0.256 0.220 0.080 0.169 0.034 0.113 0.086 0.156 0.164 0.603 0.000 0.003 0.028 0.085 Max 0.835 0.630 0.188 0.070 0.497 0.655 0.029 0.095 0.625 0.264 0.228 0.088 0.177 0.042 0.121 0.096 0.166 0.165 0.618 0.005 0.012 0.032 0.095
Millimeters Min 20.57 15.49 4.52 1.40 12.37 16.13 0.56 1.91 14.61 6.50 5.58 2.03 4.29 0.86 2.87 2.18 3.96 0.410 15.31 0.00 0.07 0.71 2.17 Max 21.21 16.00 4.78 1.78 12.62 16.64 0.74 2.41 15.88 6.71 5.79 2.24 4.49 1.07 3.07 2.44 4.22 0.420 15.70 0.13 0.30 0.81 2.42
Tc Measurement Point
A
F EZ
MT1
W
X J
Gate
N T M Y K V L
R S P
MT2
G H
Note: Maximum torque to be applied to mounting tab is 8 in-lbs (0.904 Nm). .
Dimensions — TO-3 (P Package) Fastpak — Isolated Mounting Tab
A B D
Dimension A B C D E F G H I J K L M N O P Q R S T (MT1) T (MT2) T (Gate) U (MT1) U (MT2) U (Gate) V W
Inches Min 1.531 1.177 0.843 0.780 0.783 0.874 0.161 0.386 0.508 0.079 0.047 0.307 0.372 0.043 0.315 0.098 0.846 0.244 0.106 0.321 0.321 0.220 0.246 0.246 0.183 0.120 0.175 Max 1.543 1.185 0.850 0.795 0.791 0.906 0.169 0.465 0.587 0.087 0.055 0.319 0.396 0.059 0.331 0.106 0.886 0.256 0.130 0.329 0.329 0.228 0.254 0.254 0.191 0.130 0.185
Millimeters Min 38.90 29.90 21.40 19.80 19.90 22.20 4.10 9.80 12.90 2.00 1.20 7 .80 9.45 1.10 8.00 2.50 21.50 6.20 2.70 8.15 8.15 5.60 6.25 6.25 4.65 3.05 4.45 Max 39.20 30.10 21.60 20.20 20.10 23.00 4.30 11.80 14.90 2.20 1.40 8.10 10.05 1.50 8.40 2.70 22.50 6.50 3.30 8.35 8.35 5.80 6.45 6.45 4.85 3.30 4.70
MT2 F MT1 Gate G E C I J (MT1, MT2) T U W V R K (Gate) 5N S O P Q H
TC Measur Point ing
ML
Thick ness off all three copper-alloy terminals is .032" (0.81 mm).
Maximum torque to be applied to mounting tab is 8 in-lbs (0.904Nm).
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. Qxx25xx & Qxx25xHx Series
125 Revised: May 10, 2010 09:33 PM
25 A TRIACs
Teccor® brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
Product Selector
Part Number Qxx25R5 Qxx25N5 Qxx25P5 Qxx25RH5 Qxx25LH5 Qxx25NH5 Qxx25R6 Qxx25L6 Qxx25NH6 Qxx25J6 Qxx25K6 X X X X X X X X Voltage 400V X X 600V X X X X X X X X X X X 800V X X X X X X X X X X X X X X X 1000V X X Gate Sensitivity Quadrants I - II - III 50 mA 50 mA 50 mA 50 mA 50 mA 50 mA 80 mA 80 mA 80 mA 80 mA 80 mA IV 120 mA (TYP) 120 mA (TYP) 120 mA (TYP) Package TO-220R TO-263 D2-Pak Fastpak TO-220R TO-220L TO-263 D2-Pak TO-220R TO-220L TO-263 D2-Pak TO-218X TO-218AC
Packing Options
Part Number Qxx25R5 Qxx25R5TP Qxx25N5TP Qxx25N5RP Qxx25RH5 Qxx25RH5TP Qxx25LH5 Qxx25LH5TP Qxx25NH5TP Qxx25NH5RP Qxx25P5 Qxx25R6 Qxx25R6TP Qxx25L6 Qxx25L6TP Qxx25NH6TP Qxx25NH6RP Qxx25J6TP Qxx25K6TP Marking Qxx25R5 Qxx25R5 Qxx25N5 Qxx25N5 Qxx25RH5 Qxx25RH5 Qxx25LH5 Qxx25LH5 Qxx25NH5 Qxx25NH5 Qxx25P5 Qxx25R6 Qxx25R6 Qxx25L6 Qxx25L6 Qxx25NH6 Qxx25NH6 Qxx25J6 Qxx25K6 Weight 2.20g 2.20g 1.60g 1.60g 2.20g 2.20g 2.20g 2.20g 1.60g 1.60g 21.4g 2.20g 2.20g 2.20g 2.20g 1.60g 1.60g 5.23g 4.40g Packing Mode Bulk Tube Tube Embossed Carrier Bulk Tube Bulk Tube Tube Embossed Carrier Bulk Bulk Tube Bulk Tube Tube Embossed Carrier Tube Tube Base Quantity 500 500 (50 per tube) 500 (50 per tube) 500 500 500 (50 per tube) 500 500 (50 per tube) 500 (50 per tube) 500 200 500 500 (50 per tube) 500 500 (50 per tube) 500 (50 per tube) 500 250 (25 per tube) 250 (25 per tube)
Qxx25xx & Qxx25xHx Series
126 Revised: May 10, 2010 09:33 PM
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
Teccor® brand Thyristors
25 Amp Standard & Alternistor (High Commutation) Triacs
TO-263 Embossed Carrier Reel Pack (RP) Specifications Meets all EIA-481-2 Standards
0.63 (16.0)
0.157 (4.0) Gate 0.059 DIA (1.5) MT1 / Cathode
0.945 (24.0)
0.827 (21.0)
*
* Cover tape
MT2 / Anode 12.99 (330.0) Dimensions are in inches (and millimeters).
0.512 (13.0) Arbor Hole Dia.
1.01 (25.7)
Direction of F eed
Part Numbering System
Q 60 25 N H6
DEVICE TYPE Q: Triac or Alternistor SENSITIVITY Standard Triac 5: 50mA Alternistor H5: 50mA 6: 80mA H6: 80mA PACKAGE TYPE L : TO-220AB Isolated R : TO-220AB Non-Isolated N : TO-263 (D2 -Pak) K : TO-218AC Isolated J : TO-218X Isolated P : Fastpak
Part Marking System
TO-220AB (R & L Packages) TO-263 (N Package) TO-218AC (K Package) TO-218X (J Package)
Q6025K6
Q6025L5
®
VOLTAGE RATING 40: 400V 60: 600V 80: 800V K0: 1000V CURRENT RATING 25: 25A
yxxxx
®
yxxxx
Fastpak (P Package)
®
Q6025P5 yxxxx
©2010 Littelfuse, Inc Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information.
127 Revised: May 10, 2010 09:33 PM
Qxx25xx & Qxx25xHx Series
25 A TRIACs