RLD60P030X

RLD60P030X

  • 厂商:

    LITTELFUSE

  • 封装:

  • 描述:

    RLD60P030X - These 60V RLDs were designed to be generalpurpose resettable fuses - Littelfuse

  • 详情介绍
  • 数据手册
  • 价格&库存
RLD60P030X 数据手册
POLYFUSE® RESETTABLE FUSES RLD60 Radial Leaded, 60 V Standard UL 1434 1st Edition CSA C22.2 No. 0 CSA TIL No. CA-3A cULus Recognition TÜV Specifications Packaging A* G F* * preferred type bulk tape and reel tape and ammo Approvals Features Dimensions (mm) These 60V RLDs were designed to be generalpurpose resettable fuses. As such, they are capable of protecting a large variety of circuits, including power supplies, speakers, security and alarm systems, certain motors etc. Insulating Material: Yellow Epoxy Polymer, UL 94 V-0 Round Pins: Copper alloy, tin plated Max. Device Surface Temperature in Tripped State 125 °C Operating / Storage Temperature -40 ºC to +85 ºC (consider derating) Humidity Ageing +85 °C, 85 % R.H., 1000 hours, ± 5 % typical resistance change Soldering Characteristics Solderability per MIL-STD-202, Method 208E Thermal Shock MIL-STD-202F, Method 107G +125 °C to -40 °C 10 times, ±10 % typical resistance change Solvent Resistance MIL-STD-202, Method 215F, no change Marking “P”, voltage, amperage rating, lot number Materials Dimensions (mm) Model RLD60P010X RLD60P017X RLD60P020X RLD60P025X RLD60P030X RLD60P040X RLD60P050X RLD60P065X RLD60P075X RLD60P090X RLD60P110X RLD60P135X RLD60P160X RLD60P185X RLD60P250X RLD60P300X RLD60P375X A Max 7.4 7.4 7.4 7.4 7.4 7.6 7.9 9.7 10.4 11.7 13.0 14.5 16.3 17.8 21.3 24.9 28.4 B Max 12.7 12.7 12.2 12.7 13.0 13.5 13.7 14.5 15.2 15.7 18.0 19.6 21.3 22.9 26.4 30.0 33.5 C typ 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 10.2 10.2 10.2 D Min 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 E Max 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 Physical Characteristics Lead Material 0.51 dia. 0.51 dia. 0.51 dia. 0.51 dia. 0.51 dia. 0.51 dia. 0.51 dia. 0.51 dia. 0.51 dia. 0.51 dia. 0.81 dia. 0.81 dia. 0.81 dia. 0.81 dia. 0.81 dia. 0.81 dia. 0.81 dia. Sn/CuFe Sn/CuFe Sn/CuFe Sn/CuFe Sn/CuFe Sn/CuFe Sn/Cu Sn/Cu Sn/Cu Sn/Cu Sn/Cu Sn/Cu Sn/Cu Sn/Cu Sn/Cu Sn/Cu Sn/Cu packaging quantity bag ammo 500 500 500 500 500 500 500 500 500 500 500 100 100 100 100 100 100 2,000 2,000 2,000 2,000 2,000 2,000 2,000 2,000 2,000 2,000 1,000 1,000 1,000 1,000 1,000 1,000 800 Permissible continuous operating current is ≤ 100 % at ambient temperature of 20 ºC (68 ºF). Model cURus • • • • • • • • • • • • • • • • • RLD60P010X RLD60P017X RLD60P020X RLD60P025X RLD60P030X RLD60P040X RLD60P050X RLD60P065X RLD60P075X RLD60P090X RLD60P110X RLD60P135X RLD60P160X RLD60P185X RLD60P250X RLD60P300X RLD60P375X NOTE: I hold = I trip = Vmax = I max = 0.10 0.17 0.20 0.25 0.30 0.40 0.50 0.65 0.75 0.90 1.10 1.35 1.60 1.85 2.50 3.00 3.75 0.20 0.34 0.40 0.50 0.60 0.80 1.00 1.30 1.50 1.80 2.20 2.70 3.20 3.70 5.00 6.00 7.50 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 4.00 @ 0.50 3.00 @ 0.85 2.20 @ 1.00 2.50 @ 1.25 3.00 @ 1.50 3.80 @ 2.00 4.00 @ 2.50 5.30 @ 3.25 6.30 @ 3.75 7.20 @ 4.50 8.20 @ 5.50 9.60 @ 6.75 11.40 @ 8.00 12.60 @ 9.25 15.60 @ 12.50 19.80 @ 15.00 24.00 @ 18.75 0.38 0.48 0.41 0.45 0.49 0.56 0.77 0.88 0.92 0.99 1.50 1.70 1.90 2.10 2.50 2.80 3.20 2.500 3.300 1.830 1.250 0.880 0.550 0.500 0.310 0.250 0.200 0.150 0.120 0.090 0.080 0.050 0.040 0.030 7.500 8.000 4.400 3.000 2.100 1.290 1.170 0.720 0.600 0.470 0.380 0.300 0.220 0.190 0.130 0.100 0.080 Hold current: maximum current device will pass without tripping in 20 °C still air. Trip current: minimum current at which the device will trip in 20 °C still air. Maximum voltage device can withstand without damage at rated current (I max) Maximum fault current device can withstand without damage at rated voltage (Vmax) Pd = Power dissipated from device when in the tripped state at 20 °C still air. Minimum resistance of device in initial (un-soldered) state. R min= R 1max= Maximum resistance of device at 20 °C measured one hour after tripping for 20 s. Caution: Operation beyond the specified rating may result in damage and possible arcing and flame. Specifications are subject to change without notice Order Information Qty. OrderNumber Model * Packaging * optional "F" for lead free devices 040706 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com TÜV p p • • • • • • • • • • • • • • • Ihold (A) ITrip (A) Vmax. dc (V) Imax. (A) max. time to trip (s @ A) Pd max. (W) Resistance R min.( ) RI max.( ) Approvals POLYFUSE® RESETTABLE FUSES RLD60 A: RLD60P010X B: RLD60P017X C: RLD60P020X D: RLD60P025X E: RLD60P030X F: RLD60P040X G: RLD60P050X H: RLD60P065X I: RLD60P075X J: RLD60P090X K: RLD60P110X L: RLD60P135X M: RLD60P160X N: RLD60P185X O: RLD60P250X P: RLD60P300X Q: RLD60P375X Thermal Derating Chart Model RLD60P010X RLD60P017X RLD60P020X RLD60P025X RLD60P030X RLD60P040X RLD60P050X RLD60P065X RLD60P075X RLD60P090X RLD60P110X RLD60P135X RLD60P160X RLD60P185X RLD60P250X RLD60P300X RLD60P375X Ambient Operation Temperature - Ihold (A) -40 °C 0.16 0.26 0.31 0.39 0.47 0.62 0.78 1.01 1.16 1.40 1.71 2.09 2.48 2.87 3.88 4.65 5.81 -20 °C 0.14 0.23 0.27 0.34 0.41 0.54 0.68 0.88 1.02 1.22 1.50 1.84 2.18 2.52 3.40 4.08 5.10 0 °C 0.12 0.20 0.24 0.30 0.36 0.48 0.60 0.77 0.89 1.07 1.31 1.61 1.90 2.20 2.98 3.57 4.46 23 °C 0.10 0.17 0.20 0.25 0.30 0.40 0.50 0.65 0.75 0.90 1.10 1.35 1.60 1.85 2.50 3.00 3.75 40 °C 0.08 0.14 0.16 0.20 0.24 0.32 0.41 0.53 0.61 0.73 0.89 1.09 1.30 1.50 2.03 2.43 3.04 50 °C 0.07 0.12 0.14 0.18 0.22 0.29 0.36 0.47 0.54 0.65 0.79 0.97 1.15 1.33 1.80 2.16 2.70 60 °C 0.06 0.11 0.13 0.16 0.19 0.25 0.32 0.41 0.47 0.57 0.69 0.85 1.01 1.17 1.58 1.89 2.36 70 °C 0.05 0.09 0.11 0.14 0.16 0.22 0.27 0.35 0.41 0.49 0.59 0.73 0.86 1.00 1.35 1.62 2.03 85 °C 0.04 0.07 0.08 0.10 0.12 0.16 0.20 0.26 0.30 0.36 0.44 0.54 0.64 0.74 1.00 1.20 1.50 040706 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com
RLD60P030X
### 物料型号 - RLD60P010X - RLD60P017X - RLD60P020X - RLD60P025X - RLD60P030X - RLD60P040X - RLD60P050X - RLD60P065X - RLD60P075X - RLD60P090X - RLD60P110X - RLD60P135X - RLD60P160X - RLD60P185X - RLD60P250X - RLD60P300X - RLD60P375X

### 器件简介 POLYFUSE® RESETTABLE FUSES RLD60系列是一般用途的可重置保险丝,能够保护多种电路,包括电源、扬声器、安全和报警系统、某些电机等。

### 引脚分配 - 引脚材料:铜合金,锡镀层 - 引脚直径:0.51mm或0.81mm,具体尺寸依据型号而定

### 参数特性 - 持续工作电流:在20°C环境温度下不超过100% - 保持电流(Hold current):设备在20°C静止空气中能通过的最大电流而不触发。 - 触发电流(Trip current):设备在20°C静止空气中触发的最小电流。 - 最大电压(V max.dc):设备在额定电流下能承受的最大电压,无损坏。 - 最大故障电流(I max):设备在额定电压下能承受的最大故障电流,无损坏。 - 在20°C静止空气中,设备触发状态下散发的功率(Pdmox)。 - 设备初始(未熔断)状态的最小电阻。 - 在20°C下,设备触发20秒后1小时测量的最大电阻。

### 功能详解 这些60V RLDs旨在提供电路保护解决方案,具备技术专长和应用领导力,将WICKMANN集团及其产品引入Littelfuse产品组合。

### 应用信息 适用于多种电路保护,包括电源、扬声器、安全和报警系统、某些电机等。

### 封装信息 - 绝缘材料:黄色环氧聚合物,UL 94 V-0 - 包装:散装、胶带和卷轴、弹药包装 - 最大设备表面温度在触发状态:125°C - 操作/存储温度:-40°C至+85°C(考虑降额) - 湿度老化:+85°C,85%R.H.,1000小时,典型电阻变化±5% - 焊接特性:根据MIL-STD-202,方法208E焊接性 - 热冲击:根据MIL-STD-202F,方法107G,+125°C至-40°C,10次,典型电阻变化±10%