0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
LWH1035

LWH1035

  • 厂商:

    LUXPIA

  • 封装:

  • 描述:

    LWH1035 - SMD Top View Type - LUXPIA

  • 数据手册
  • 价格&库存
LWH1035 数据手册
LWH1035 - CONTENTS - 1. Features 2. Package Outline Dimensions 3. Package material 4. Absolute Maximum Ratings 5. Electrical Optical Characteristics 6. Ranks 7. Taping 8. Packing Structure 9. Characteristic Diagrams 10. Reliability 11. Cautions 12. Warranty 13. Others 14. Revision history sheet Different and Better 1/17 LWH1035 1. Features • Package : SMD Top View Type • 3.5 × 2.7 × 1.8 mm(L×W×H) small size surface mount type • Color Coordinates : x = 0.31, y = 0.32 acc. to CIE 1931, at IF=20mA • Viewing angle : extremely wide(120˚) • Technology : InGaN • Soldering methods : IR reflow soldering • Taping : 8 mm conductive black carrier tape & antistatic clear cover tape. 2,000pcs/reel, Φ180 mm wheel 2. Package Outline Dimensions (unit : mm) Different and Better 2/17 LWH1035 3. Package material (1) Material construction Number 1 2 3 4 5 6 Item LED Chip Gold Wire Lead Frame Epoxy or Silicon Resin Heat-Resistant Polymer Zener Diode Chip Different and Better 3/17 LWH1035 4. Absolute Maximum Ratings Parameter Power dissipation Forward Current *1Peak Forward Current *2Reverse Current Operating Temperature Storage Temperature Reflow Soldering Temperature Symbol PD IF IFP IRDC Topr Tstg Tsol Value 120 30 100 100 -30∼+85 -40∼+100 (Ta = 25℃) Unit mW mA mA mA ℃ ℃ Reflow Soldering : 260℃ for 10 sec. Hand Soldering : 350℃ for 3 sec. *1. IFP Conditions : Pulse Width ≤ 10msec. and Duty ≤ 1/10 *2. IRDC Rating : This Rating for Zener Diode 5. Electrical - Optical Characteristics Characteristic Forward Voltage Reverse Voltage Reverse Current *3Half Angle 3 (Ta = 25℃) Min. Typ. 3.3 ±60 Max. 3.6 2 10 Unit V V mA deg Symbol VF VR IR θ1/2 Test Condition IF= 20mA IR=10mA VR=0.5V IF= 20mA * θ1/2 is the off-axis angle where the luminous intensity is 1/2 the peak intensity ESD Class(Mil Std-883d Method 3015.7) based on Human Body Model(HBM) : Class 3 ESD Class(EIAJ ED-4701A) based on Machine Model(MM) : Class 4 Different and Better 4/17 LWH1035 6. Ranks (1) Chromaticity Coordinates ranks Rank A x y 0.27 0.24 0.27 0.28 0.29 0.27 0.29 0.31 x y 0.29 0.27 (IF=20mA, Ta=25℃) Rank B 0.29 0.31 0.31 0.30 0.31 0.34 Rank C x y 0.31 0.30 0.31 0.34 0.33 0.33 0.33 0.37 * The CIE(1931) standard colorimetric system * Chromaticity coordinates Measured : 0.01sr(CIE. LED_B) * Measurement Uncertainty of the Color Coordinates : ±0.01 Different and Better 5/17 LWH1035 (2) Luminous intensity ranks Iv RANK M N IF= 20mA O P 850 1200 1200 1700 Test Condition Min. 420 600 Typ. Max. 600 850 mcd (Ta=25℃) Unit * Luminous intensity is tested at a current pulse duration of 25 ms and an accuracy of ±11%. * Luminous Intensity Measured : 0.01sr(CIE. LED_B) (3) Forward Voltage VF RANK 0 1 IF=20mA 2 3 3.4 3.6 3.6 3.8 Test Condition Min. 2.9 3.2 Typ. Max. 3.2 3.4 (Ta=25℃) Unit V * Voltages are tested at a current pulse duration of 1 ms and an accuracy of ±0.1V. (4) Precautions On LED using * To avoid optical difference, Please do not mix differently-ranked product. Different and Better 6/17 LWH1035 7. Taping (1) Dimension of wheel((Material : PS Conductive, 10E9~12Ω) (Unit : mm) (2) Dimension of tape(Material : PS Conductive, 10E4~5Ω) (Unit : mm) Different and Better 7/17 LWH1035 (3) Details of CHIP LEDs loading on tape (End) more than 40mm unloaded tape mounted with LED (2,000ea) more than 40mm unloaded tape 150 ~ 380mm leading part (Start) (4) Loading quantity per reel : 2,000pcs (5) Label Outline * SIZE(L X W) : 85mm X 50mm Different and Better 8/17 LWH1035 8. Packing Structure • The LEDs are packed in cardboard boxes after taping Please refer to figure : page 8 The label on the minimum packing unit shows : Part Number, Lot Number, Ranking, Quantity • In order to protect the LEDs from mechanical shock, we pack them in cardboard boxes for transportation. • The LEDs may be damaged if the boxes are dropped or receive a strong impact against them, so precautions must be taken to prevent any damage. • The boxes are not water resistant and therefore must be kept away from water and moisture. • When the LEDs are transported, we recommend that you use the same packing method as Luxpia. • If a box shows noticeable damage upon arrival at the User’s warehouse. It is recommended that the User submit a claim to Luxpia within one weeks after arrival of the products. If the submitted notice regarding the damage exceeds the aforementioned two weeks, it will be treated in the manner shown in term 13. Different and Better 9/17 LWH1035 9. Characteristic Diagrams (1) Relative Luminous Intensity vs Forward Current (IF-Iv) 1.6 1.4 Relative Luminosity 1.2 1.0 0.8 0.6 0.4 0.2 0.0 0 5 10 15 20 25 30 Allowable If(m A) 35 30 25 20 15 10 5 0 0 20 40 60 80 100 (2) Max. Permissible Forward Current Forw ard Current(mA) A mbient Temp.(℃) (3) Forward Current vs Forward Voltage(IF-VF) 80 70 60 50 40 30 20 10 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 (4) Ambient Temperature vs Relative Luminosity 10 Forward Current IF[mA] Relative Luminosity 1 0.1 -40 -20 0 20 40 60 80 100 Forward Voltage VF[V] Ambient Temp(℃) Different and Better 10/17 LWH1035 (5) Relative Spectral Emission V(λ) = Standard eye response curve (Ta=25℃ , IF = 20mA) (6) Radiation Characteristic (Ta=25℃ , IF = 20mA) Different and Better 11/17 LWH1035 10. Reliability (1) The Reliability criteria of SMD LED Limit ITEM Forward Voltage Reverse Voltage Luminous intensity * I.V : Initial Value Symbol VF VR Test Condition Min. IF = 20mA IR = 10mA IF = 20mA I.V × 0.9 I.V × 0.9 I.V × 0.7 Max. I.V × 1.1 I.V × 1.1 - Iv U : Upper Spec Limit L : Lower Spec Limit (2) Results of reliability Test NO 1 2 3 4 Item Steady State Operating Life Steady State Operating Life of Low Temperature Steady State Operating Life of High Temperature Steady State Operating Life of High Humidity Heat Temperature Cycle Test Conditions Ta=25℃, If=30mA Ta=-30℃, If=20mA Ta=85℃, If=7.5mA Ta=60℃, RH=90%, If=20mA Ta=-40℃~25℃~100℃~25℃ Time=30min~5min~30min~5min Time 1000hrs 1000hrs 1000hrs 1000hrs Ac/Re (검토,보증) 0/22, 0/45 0/22, 0/45 0/22, 0/45 0/22, 0/45 5 100Cycle 0/22, 0/45 6 7 8 9 10 Low Temperature Storage High Temperature Storage Temperature Humidity Storage SHT(Reflow) Solderability(Reflow) Ta=-40℃ Ta=100℃ Ta=60℃, RH=90% Tsld=240℃, 10sec Tsld=230±5℃, 3sec 1000hrs 1000hrs 1000hrs 1 time 1 time (over5%) 0/22, 0/45 0/22, 0/45 0/22, 0/45 0/22, 0/45 0/22, 0/45 Different and Better 12/17 LWH1035 11. Cautions White LEDs are devices which are materialized by combining Blue LEDs and special phosphors. Consequently, the color of White LEDs is changed a little by an operating current. Care should be taken after due consideration when using LEDs. (1) Moisture Proof Package • When moisture is absorbed into the SMT package it may vaporize and expand during soldering. There is a possibility that this can cause exfoliation of the contacts and damage to the optical characteristics of the LEDs. For this reason, the moisture proof package is used to keep moisture to a minimum in the package. • A package of a moisture absorbent material (silica gel) is inserted into the shielding bag. The silica gel changes its color from blue to pink as it absorbs moisture. (2) Storage • Storage Conditions Before opening the package : The LEDs should be kept at 30℃ or less and 90%RH or less. The LEDs should be used within a year. When storing the LEDs, moisture proof packaging with absorbent material (silica gel) is recommended. After opening the package : The LEDs should be kept at 30℃ or less and 70%RH or less. The LEDs should be soldered within 168 hours (7days) after opening the package. If unused LEDs remain, they should be stored in moisture proof packages, such as sealed containers with packages of moisture absorbent material (silica gel). It is also recommended to return the LEDs to the original moisture proof bag and to reseal the moisture proof bag again. • If the moisture absorbent material (silica gel) has faded away or the LEDs have exceeded the storage time, baking treatment should be performed using the following conditions. Baking treatment : more than 24 hours at 65±5℃ • Luxpia LED electrode sections are comprised of a silver plated copper alloy. The silver surface may be affected by environments which contain corrosive gases and so on. Please avoid condition may cause difficulty during soldering operations. It is recommended that the User use the LEDs as soon as possible. • Please avoid rapid transitions in ambient temperature, especially in high humidity environments where condensation can occur. (3) Heat Generation • Thermal design of the end product is of paramount importance. Please consider the heat generation of the LED when making the system design. The coefficient of temperature increase per input electric power is affected by the thermal resistance of the circuit board and density of LED placement on the board, as well as other components. It is necessary to avoid intense heat generation and operate within the maximum ratings given in this specification. • The operating current should be decided after considering the ambient maximum temperature of LEDs. Different and Better 13/17 LWH1035 (4) Soldering Conditions • The LEDs can be soldered in place using the reflow soldering method. Luxpia cannot make a guarantee on the LEDs after they have been assembled using the dip soldering method. • Recommended soldering conditions Reflow Soldering Hand Soldering Lead Solder Lead-free Solder Temperature 350℃ Max Pre-heat 180~200℃ 120~150℃ Soldering time 3sec Max Pre-heat time 120sec Max 120sec Max (one time only) Peak temperature 240℃ Max 260℃ Max Soldering time 10sec Max 10sec Max refer to refer to Temperature Temperature 1 2 - profile ○ - profile ○ * After reflow soldering rapid cooling should be avoided. Temperature-profile (Surface of circuit board) Use the conditions shown to the under figure. 1 2 [○ : Lead-free Solder] [○ : Lead Solder] [Recommended soldering pad design] Use the following conditions shown in the figure. Different and Better 14/17 LWH1035 • Occasionally there is a brightness decrease caused by the influence of heat or ambient atmosphere during air reflow. It is recommended that the User use the nitrogen reflow method. • Repairing should not be done after the LEDs have been soldered. When repairing is unavoidable, a double-head soldering iron should be used. It should be confirmed beforehand whether the characteristics of the LEDs will or will not be damaged by repairing. • Reflow soldering should not be done more than two times. • When soldering, do not put stress on the LEDs during heating. • After soldering, do not warp the circuit board. (5) Cleaning • It is recommended that isopropyl alcohol be used as a solvent for cleaning the LEDs. When using other solvents, it should be confirmed beforehand whether the solvents will dissolve the package and the resin or not. Freon solvents should not be used to clean the LEDs because of worldwide regulations. Do not clean the LEDs by the ultrasonic. When it is absolutely necessary, the influence of ultrasonic cleaning on the LEDs depends on factors such as ultrasonic power and the assembled condition. Before cleaning, a pre-test should be done to confirm whether any damage to the LEDs will occur. (6) Static Electricity • Static electricity or surge voltage damages the LEDs. It is recommended that a wrist band or an anti-electrostatic glove be used when handling the LEDs. • All devices, equipment and machinery must be properly grounded. It is recommended that measures be taken against surge voltage to the equipment that mounts The LEDs. •When inspecting the final products in which LEDs were assembled,it is recommended to check whether the assembled LEDs are damaged by static electricity or not. It is easy to find staticdamaged LEDs by a light-on test or a VF test at a lower current(below 1mA is recommended). • Damaged LEDs will show some unusual characteristics such as the leak current remarkably increases, the forward voltage becomes lower, or the LEDs do not light at the low current. Criteria : (VF > 2.0V at IF=0.5mA) (7) Others • Care must be taken to ensure that the reverse voltage will not exceed the absolute maximum rating when using the LEDs with matrix drive. • The LED light output is strong enough to injure human eyes. Precautions must be taken to prevent looking directly at the LEDs with unaided eyes for more than a few seconds. • Flashing lights have been known to cause discomfort in people; you can prevent this by taking precautions during use. Also, people should be cautious when using equipment that has had LEDs incorporated into it. Different and Better 15/17 LWH1035 12. Warranty (1) Luxpia warrants that its LEDs conform to the foregoing specifications and that Luxpia will convey good title to all LEDs sold. (2) Luxpia Disclaims all other warranties including the implied warranties of merchantability and fitness for a particular purpose. (3) In the event any LED supplied by Luxpia is found not to conform to the foregoing specifications within ninety days of receipt, Luxpia will repair or replace the LED, at Luxpia’s discretion, provided that the User (1) promptly notifies Luxpia in writing of the details of the defect (2) ships the LEDs at the User’s expense to Luxpia for examination, and (3) the defect is due to the negligence of Luxpia and not mishandling or misuse by the User. (4) Luxpia will not take responsibility for any trouble that is caused by using the LEDs at conditions exceeding our specifications. (5) These specifications are applied only when a LED stands alone and it is strongly recommended that the User of the LEDs confirms the properties upon assembly. Luxpia is not responsible for failures caused during and after assembling. It will be excepted from the rule if the failure would caused undoubtedly by Luxpia. (6) A claim report stating details about the defect shall be made when returning defective LEDs. Luxpia will investigate the report immediately and inform the user of the results. (7) The LEDs described in this brochure are intended to be used for ordinary electronic equipment (Such as office equipment, communications equipment, on the applications in which exceptional quality and reliability are required, particularly when the failure or malfunction of the LEDs may directly jeopardize life or health (such as for airplanes, aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic control equipment, life support systems and safety devices) (8) Luxpia’s liability for defective lamps shall be limited to replacement and in no event shall Luxpia be liable for consequential damage or lost profits. 13. Others (1) The warranties of quality set forth herein are exclusive. All previous negotiations and agreements not specifically incorporated herein are superseded and rendered null and void. (2) Both parties shall sincerely try to find a solution when any disagreement occurs regarding these specifications. (3) User shall not reverse engineer by disassembling or analysis of the LEDs without having prior written consent from Luxpia. When defective LEDs are found, the User shall inform Luxpia directly before disassembling or analysis. (4) These specifications can be revised upon mutual agreement. (5) Luxpia understands that the User accepts the content of these specifications, if the User does not return these specifications with signatures within 3 weeks after receipt. Different and Better 16/17 LWH1035 14. Revision history sheet Spec NO. Title Times 1 2 3 4 5 6 Date 2003. 2004. 2004. 2005. 2005. 2006. 04. 09. 11. 06. 11. 03. 16 09 15 29 21 15 Specification for Approval Summary of revision 신규제정 Format 변경 Mold재료 및 Soldering 조건 추가 VR, IR 조건 추가 Iv “ P” Rank 추가 Lead Frame Change Remarks Different and Better 17/17
LWH1035 价格&库存

很抱歉,暂时无法提供与“LWH1035”相匹配的价格&库存,您可以联系我们找货

免费人工找货