Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
Multipurpose Power Line RFI Filter for Emission Control
S Series
UL Recognized CSA Certified VDE Approved
20VS1 3VS1
S Series
• Combines Line to Ground interference rejection filters with additional circuitry to reduce Line to Line noise and transients • Designed for use when equipment impedance at RF frequencies is high • Effective for use with switch-mode power supplies • Effective when used to control emissions in equipment using SCR and T2L circuits for compliance with FCC Part 15, Subpart J and EN55022, Level A, down to 150kHz
Specifications
Maximum leakage current each Line to Ground: 3 & 20A 60A @120 VAC 60 Hz: .4 mA .75 mA @250 VAC 50 Hz: .7 mA 1.25 mA Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): Operating Frequency: Rated Current: 2250 VDC 1450 VDC 250 VAC 50/60 Hz 3 to 60A
Ordering Information 20 V S 6
Input / Output Style 1 – .250 [6.3] spade terminals 6 – Threaded bolt S Series Leakage current designation V – Standard
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
Electrical Schematics 3, 6, 10VS
LINE LOAD
20VS
Current Rating 3, 6, 10, 20 or 60A
LINE LOAD
Available Part Numbers
3VS1 6VS1 10VS1 20VS1 20VS6 60VS6
60VS
LINE LOAD
68
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
Multipurpose Power Line RFI Filter for Emission Control (continued)
S Series
Case Styles S1 (3, 6, 10A) 60VS6
A E
1
.415 [10.54] ref.
B
C
D
RFI Power Line Filters
D E A
B
2.25 ± .01 57.15 ± .25
C
1.12 ref. 28.5
Case Dimensions 20VS1
Part No. 3VS1
EDB
A
B
C
6VS1 10VS1
2.00 50.8
A
C
20VS1 20VS6 60VS6
D
E
20VS6
BD
2.00 50.8
C
A
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
E
69
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
(continued)
Multipurpose Power Line RFI Filter for Emission Control
S Series
Performance Data Typical Insertion Loss
Measured in closed 50 Ohm system
3VS
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
6VS
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
10VS
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
20VS
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
60VS
db 100 90 80 70 60 50 40 30 20 10 0
0.01 0.1 1 10 30 Frequency in MHz
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
Minimum Insertion Loss
Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
70
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com