Corcom Product Guide Power Entry Module with Switch
Catalog: 1654001 Issue Date: 06.2011
C Series
UL Recognized CSA Certified VDE Approved*
3CFS1 15CS1
C Series
• Two function power entry module combining a DPST switch and an IEC 60320-1 inlet • Snap–in or flange mounting • Available with or without a shielded general purpose or medical grade filter • Two element circuit provides enhanced EMI attenuation • Reduce OEM wiring time with optional pre–connected line and switch terminals
Specifications
Maximum leakage current each Line to Ground:
F Models H & Unfiltered
@ 120 VAC 60 Hz: @250 VAC 50 Hz: Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage: Operating Frequency: Rated Current: Switch:
.25 mA .40 mA
2 A 5 A
2250 VDC 1450 VDC 250 VAC 50/60 Hz 1 to 15A*
Ordering Information 10 C F S 1
Output Styles 1 – Spade terminals Mounting Styles E – Flange Mount S – Snap–in Filter Type or Terminal Option F – General purpose H – Medical B – No filter, includes Pre–connected terminals Omit if none C Series Current Rating 1, 3, 6, 10 or 15A
(Filtered versions up to 10A)
DPST 10,000 operations at 51A max. inrush 18 lb. / 80N (max.) 15 lb. / 67N (max.)
.250 Terminal Push–on Force: .188 Terminal Push–on Force:
(size varies)
Available Part Numbers
Filtered Versions 1CHE1 1CFE1 3CHE1 3CFE1 6CHE1 6CFE1 10CHE1 10CFE1 1CHS1 1CFS1 3CHS1 3CFS1 6CHS1 6CFS1 10CHS1 10CFS1 Non–filtered Versions
Standard Terminals Pre-connected Terminals
10CS1 10CE1 15CS1 15CE1
10CBS1 10CBE1 15CBS1 15CBE1
*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC
130
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide Power Entry Module with Switch
(continued)
Catalog: 1654001 Issue Date: 06.2011
C Series
Electrical Schematics F Models
LINE LOAD
CE, CBE
A B
.210 5.34
Max.
F
C
H Models
LINE LOAD
CFS, CHS B Models
Power On/Off
3
Power Inlet Filters & Power Entry Modules
C
L
Note 1 Note 2
L G
Note 1 Note 2
G N
N
A
.210 5.34 Max.
B
Note 1: Jumpers provided on CBS and CBE versions only. Note 2: Location of optional filter
Case Styles CS, CBS
B
.210 Max. 5.34
CFE, CHE
A
C
C
F A
.210 5.34 Max.
B
131
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide Power Entry Module with Switch
(continued)
Catalog: 1654001 Issue Date: 06.2011
C Series
Case Styles (continued) CBS, CBE Pre-Connected Terminals Case Dimensions
A
Part No. CS, CBS CE, CBE CFS, CHS
B
C
CBS, CBE Side View
CBE Rear View
CBS Rear View
CFE, CHE
D
E
F
Recommended Panel Cutout
D
.06 R max 1.52
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
E
F
132
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide Power Entry Module with Switch
(continued)
Catalog: 1654001 Issue Date: 06.2011
C Series
Performance Data Typical Insertion Loss
Measured in closed 50 Ohm system
1CF
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
3CF
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
6CF
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
10CF
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
1CH
db 100 90 80 70 60 50 40 30 20 10 0
0.01 0.1 1 10 30 Frequency in MHz
3CH
db 100 90 80 70 60 50 40 30 20 10 0
0.01 0.1 1 10 30 Frequency in MHz
6CH
db 100 90 80 70 60 50 40 30 20 10 0
0.01 0.1 1 10 30 Frequency in MHz
10CH
db 100 90 80 70 60 50 40 30 20 10 0
0.01 0.1 1 10 30 Frequency in MHz
3
Power Inlet Filters & Power Entry Modules
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
Minimum Insertion Loss
Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
133
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.