Corcom Product Guide High Performance Power Inlet Filter
Catalog: 1654001 Issue Date: 06.2011
EJT Series
UL Recognized CSA Certified VDE Approved*
EJT1 EJT8
EJT Series
• Superior EMI filter with IEC 60320-1 inlet • Double three element differential mode circuit attenuates noise up to 1GHz • Up to 15A with IEC 60320-1 C14 inlet • 20A rating with IEC 60320-1 C20 inlet • Spade terminals or wire leads
Specifications
Maximum leakage current each Line to Ground: 1-15A 20A @ 120 VAC 60 Hz: .25 mA .22 mA @250 VAC 50 Hz: .43 mA .40 mA Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max.): Operating Frequency: 2250 VDC 1450 VDC 250 VAC
3
Power Inlet Filters & Power Entry Modules
50/60 Hz 1 to 20A*
Ordering Information 6 EJT 1
Output Styles 1 – .250 [6.3] spade terminals 8 – Wire leads EJT Series
Rated Current:
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
Accessories
Current Rating 1, 3, 6, 10, 15 or 20A
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Available Part Numbers
1EJT1 3EJT1 6EJT1 10EJT1 15EJT1 20EJT1 1EJT8 3EJT8 6EJT8 10EJT8 15EJT8 20EJT8
FA601: Insulating Shroud
(fits 1-15A only)
.413 Dia. 10.5 .271 Dia. 6.9
.118 3.0
*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC. 20A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 16A, 250VAC.
1.39 35.4
1.17 29.7
.767 19.5
163
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide High Performance Power Inlet Filter (continued)
Catalog: 1654001 Issue Date: 06.2011
EJT Series
Electrical Schematics
LINE LOAD
Blue
20EJT8
1
DE
Green/Yellow Brown
B
1
A
Note 1: 20A Versions only
C
Case Styles EJT1
C B D E
A
Case Dimensions
Part No. EJT1 EJT8 A
B
C
D
E
20EJT1
C B A
20EJT1 20EJT8
D E
Recommended Panel Cutouts
1 to 15A
1.575 40.00
EJT8
Blue Green/Yellow
20A
1.654 42.01 1.370 34.80
DE
Brown
B
1.20 30.48
.820 20.83 0.140 Dia. 3.56
A
Front Mount Only Tolerance ±.005 [.13]
1.055 26.80 0.138 Dia. 3.51
R
.062 Max. 1.57
R
.062 Max. 1.57
C
164
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide High Performance Power Inlet Filter (continued)
Catalog: 1654001 Issue Date: 06.2011
EJT Series
Performance Data Typical Insertion Loss
Measured in closed 50 Ohm system
1EJT
db 100 90 80 70 60 50 40 30 20 10 0
0.1 1 10 100 1000 Frequency in MHz
3EJT
db 100 90 80 70 60 50 40 30 20 10 0
0.1 1 10 100 1000 Frequency in MHz
6EJT
db 100 90 80 70 60 50 40 30 20 10 0
0.1 1 10 100 1000 Frequency in MHz
10EJT
db 100 90 80 70 60 50 40 30 20 10 0
0.1 1 10 100 1000 Frequency in MHz
15EJT
db 100 90 80 70 60 50 40 30 20 10 0
0.1 1 10 100 1000 Frequency in MHz
20EJT
db 100 90 80 70 60 50 40 30 20 10 0
0.1 1 10 100 1000 Frequency in MHz
3
Power Inlet Filters & Power Entry Modules
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
Minimum Insertion Loss
Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
165
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com