3100-30J9999

3100-30J9999

  • 厂商:

    MACOM

  • 封装:

  • 描述:

    3100-30J9999 - Definite Purpose Contactor 3-pole, 20-40 FLA AC Coil - Tyco Electronics

  • 数据手册
  • 价格&库存
3100-30J9999 数据手册
Catalog 1308242 Issued 3-03 (PDF Rev. 3-04) PRODUCTS UNLIMITED Model 98 - 3100 series Definite Purpose Contactor 3-pole, 20-40 FLA AC Coil File E75492 File EN60947-4-1:1991 IEC 947-4-1 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Features • 3-pole contactors. • Industry-standard mounting plate. • Optional interlock/auxiliary switches available. • Manual test button is standard. • Coil dust cover helps keep dust and dirt away from magnet and coil area. • Double E magnet system provides optimal performance. Environmental Data Temperature Range: Storage and Operating: -40°C – +65°C. Flammability: UL 94-HB housing. Mechanical Data Contact Data @ 25°C Arrangements: 3 Form X (3PST-NO-DM). Maximum Ratings: See Contact Ratings Table. Material: Silver Cadmium Oxide. Contact Termination: 20, 25, 30 FLA Models Type: #10-32 Screw with quad 0.250” (6.35 mm) quick connects. Wire Size: 16-8 AWG (Stranding must be split for 8 AWG wire.) Tightening Torque: 25 in.-lbs. 40 FLA Models Type: Box Lug with dual 0.250” (6.35 mm) quick connects. Wire Size: 14-4 Cu/Al AWG Tightening Torque: 40 in.-lbs. Coil Termination: Dual 0.250” (6.35 mm) quick connects, standard. A 0.250” quick connect and a #6-32 screw, optional. Arc Cover: Optional on 20-30 FLA models, standard on 40 FLA models. Weight: 16 oz. (455 g) approximately Coil Data @ 25°C Voltage: 24 - 480 VAC, 50/60 Hz. See Coil Data Table below. Insulation Class: UL Class B (130°C). Duty Cycle: Continuous. Contact Ratings Full Load Amps 20 Number of Poles 3 Line Voltage 240/277 480 600 240/277 480 600 Locked Rotor Amps 120 100 80 150 125 100 Resistive Amps Rating 30 30 30 35 35 35 Voltage 110/120 200/240 480/600 110/120 200/208 240/277 480 600 110/120 200/208 240/277 480 600 110/120 200/208 240/277 480 600 Maximum Horsepower Single Phase 1.5 3 2 5 2 5 3 7.5 Three Phase 7.5 7.5 7.5 10 15 20 10 10 15 20 10 10 20 25 25 3 30 3 240/277 480 600 180 150 120 40 40 40 40 3 240/277 480 600 240 200 160 50 50 50 Coil Data Nominal Coil Voltage Maximum Pickup Volts Drop-Out Volts Range Nominal Inrush VA @ 50 Hz Nominal Inrush VA @ 60 Hz Nominal Sealed VA @ 50 Hz Nominal Sealed VA @ 60 Hz Nominal DC Resistance - Ohms 24 18 6 -15 60 53 6.0 5 7 120 88 20 - 70 60 53 6.0 5 180 208/240 177 40 - 140 60 53 6.0 5 720 277 220 65 - 185 60 53 6.0 5 950 480 384 150 - 270 65 53 6.0 5 3100 Dimensions are shown for 832 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Rev. 3-04) PRODUCTS UNLIMITED Ordering Information Typical Part No. B 3100 - 30 Q 9 999 1. Series: 3100 = 3-pole, 20-40 FLA contactor 2.Packaging: Y = Individual Pack - = Bulk Pack A-ZZZ = Customer specific information (assigned by factory) 3.Pole Configuration: 30 = 3 Form X (3PST-NO-DM) 4.Coil Voltage (50/60 Hz.): Q = 24VAC U = 208/240VAC H = 480VAC J = 120VAC, molded M = 277VAC, molded T = 120VAC V = 277VAC I = 24VAC, molded K = 208/240VAC, molded W = 480VAC, molded 5.Contact Ratings (Inductive): 7 = 20 FLA 8 = 25 FLA 9 = 30 FLA 10 = 40 FLA 6.Customer ID Suffix: 999 = Standard Model 000-998 = Factory assigned customer ID 7. Option Code: Leave Blank = No customer-specific options A - ZZ = Factory assigned customer-specific options. Standard part numbers listed below are more likely to be available from stock. 3100-30Q9999CY 3100-30T9999CY 3100-30U9999CY 3100-30Q10999CG 3100-30T10999CG 3100-30U10999CG Outline Dimensions 3.00 (76.2) 2.97 1.78 (75.44) 1.19 (45.21) (30.23) .250 TYP. (6.35) 2.00 (50.8) Termination Options .253 (6.43) .203 TYP. (5.156) 3.39 (86.1) .455 DIA. (11.56) 3.25 (82.55) 3.75 (95.25) Standard on Special on 20, 25, 30, 35 FLA 20, 25, 30, 35 FLA #10-32 Combination #10-32 Sems Phillips, Slotted & Screw 5/16 Hex Head with Pressure #12 Washer Plate Standard on 40 FLA Lug accepts 14-4 Cu/Al AWG 2.0 MAX. (50.8) Shown with Optional Auxiliary Switches .125 .203 TYP. (3.175) (5.156) 2.375 TYP. (60.325) ORDERING NOTE: “Standard” terminals need not be specified in the “Ordering Information” chart above. “Special” terminals are offered on a special order basis. Special order items may be subject to extended leadtimes and significant minimum order quantities. Your Tyco Electronics sales engineer must consult with the factory before providing price and availability information regarding items with these options. Auxiliary Switches Various interlock / auxiliary switches are available for the Model 98 contactor. All auxiliary switches for the Model 98 are snap-on design, no tools required. Equipped with 0.250” (6.35) Quick Connect Terminals Factory Modifications Contact Config. NO NC Single unit interlock 1 0 configurations listed. 0 1 Maximum of two. 1 1 (One on each side.) 2 0 0 2 See footnote (1) for ratings. 2 2 SPDT Circuit 1 1 (Either one or two 2 2 switches per side.) 2 2 See footnote (2) for ratings. 4 4 SPDT Dry Circuit 1 1 0.1 amp max. 2 2 Gold Flashed Contacts 4 4 Description Field Added Kits Kit Catalog Number of Number Kits Required 98220-303 1 98220-331 1 98220-332 1 98220-303 2 98220-331 2 98220-332 2 98220-337 1 98220-338 1 98220-337 2 98220-338 2 98220-341 1 98220-340 1 98220-340 2 ONE SPDT SWITCH PER SIDE TWO SPDT SWITCHES PER SIDE 1 N/O / 1 N/C Equipped with #6-32 Screw Terminals & Saddle Clamps Footnotes: Ratings of Auxiliary Interlocks / Switches (1) Contact Rating Single Circuit NO or NC and two circuit NO/NC: 120V 240V 480V 600V Amperes - Break 3.0 1.5 0.75 0.6 Amperes - Make 30 15 7.5 6 Amperes - Continuous 10 10 10 10 (2) Contact Rating SPDT (337): 10A, 1/3 HP 125 or 250 VAC , 1/2A, 125 VDC; 1/4A, 250 VDC: 4A 120 VAC on Lamp Load Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Factory Modifications Contact Config. NO NC Single unit interlock 1 0 configurations listed. 0 1 Maximum of two. 1 1 (One on each side.) 2 0 0 2 See footnote (1) for ratings. 2 2 Description Field Added Kits Kit Catalog Number of Number Kits Required 98220-303 1 98220-331 1 98220-332 1 98220-303 2 98220-331 2 98220-332 2 Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. 833
3100-30J9999 价格&库存

很抱歉,暂时无法提供与“3100-30J9999”相匹配的价格&库存,您可以联系我们找货

免费人工找货