0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6EHL1SCM

6EHL1SCM

  • 厂商:

    MACOM

  • 封装:

  • 描述:

    6EHL1SCM - Power Entry Module with RFI Power Line Filter for General or Medical Applications - Tyco ...

  • 数据手册
  • 价格&库存
6EHL1SCM 数据手册
CORCOM Product Guide Power Entry Module with RFI Power Line Filter for General or Medical Applications L Series UL Recognized CSA Certified VDE Approved EDL4C/EHL4C EDL1S/EHL1S L Series The L series power entry modules are compact units that combine a multi-function power entry module and high performance RFI filtering capabilities. They are available with either a four-voltage selector or a DPST on/off switch. Both variations can be specified with North American or European fusing capabilities and are available in either flange or snap-in mounting. These filters are UL recognized, CSA certified, and VDE approved. The L series modules offer a choice of filters for general or medical applications. EDL Models The RFI filter is for general purpose applications where line-to-line and line-to-ground noise must be controlled. The filter is designed to meet the very low leakage requirements of VDE portable equipment. They are available in three current ratings. EHL Models This medical filter provides susceptibility protection without the leakage current associated with line-to-ground capacitors. Designed to allow equipment to meet UL544 for patient care and non-patient care equipment, the EHL filter has a maximum leakage current of 2 µA at 120 VAC 60 Hz. See Appendix C for more information on medical applications and UL standards. Note: When using the models with an IEC connector, remember that the leakage current of the companion line cord, GA400, is more significant than that of the filter which may disqualify this line cord from use in patient care applications. Voltage Selection To change selected voltage: disconnect the power cord; open cover using a small blade screwdriver or similar tool; insert the tool into the voltage selection slot and remove wheel from unit; select desired voltage; replace wheel into unit and close cover, making sure the selected voltage appears in connector window. Note: All models have North American or dual European fusing capability and are available in either flange or snap-in mounting. Voltage selection slot 4-Voltage selection wheel Fuseholder Cover 118 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide Power Entry Module with RFI Power Line Filter for General or Medical Applications (Continued) L Series Electrical Schematics DL Models (with switch) Note 1 H Note 2 On/Off 2 (1) (2) 4 1 (1a) (2a) 3 Specifications Maximum leakage current, each line-to-ground: EDL EHL Models Models 0.25 mA 2 µA 0.50 mA 5 µA Neutral Ground Cutomer Transformer Primaries @120 VAC 60 Hz: @250 VAC 50 Hz: Hipot rating (one minute): line-to-ground line-to-line Operating frequency: Operating voltages: 1S & 1SC Suffix (fixed): 4 & 4C Suffix (selectable): Rated current: 2EDL & 2EHL 4EDL & 4EHL 6EL, 6EDL & 6EHL Switch: Hot G Device 1500 1450 1500 1450 Power Entry Modules 50/60 Hz 250 VAC Max. 100, 120, 220, 240 VAC DL Models (with 4-voltage selection) Cutomer 120V 100V 220V 240V Transformer Primaries A B C D E F 120V 20V Hot Note 1 G Note 2 On/Off A B C D E A B C D E F 100V Ground Neutral F H 2A 4A 6A Double-insulated, rated for 10,000 operations at full load. 51 Amp inrush capability. Accepts one .25" x 1.25" fuse or two 5 x 20 mm fuses 110 [2.79] except for switch .187 [4.8] for switch Fuse (not included): HL Models (with switch) Note 2 On/Off 2 (1) (2) 4 1 (1a) (2a) 3 Neutral Ground Note 1 H Customer Transformer Primaries Terminals: Minimum insertion loss in dB: Hot G Device HL Models (with 4-voltage selection) 120V 100V 220V 240V Customer Transformer Primaries A B C D E F 120V 20V Line-to-ground in 50 ohm circuit Current Frequency-MHz .15 1 5 .05 Rating EDL Models 2A 6 14 24 40 18 32 8 4A 2 6A 1 6 17 31 EHL Models 06A 3 8 15 18 Line-to-line in 50 ohm circuit 10 45 38 37 18 30 50 45 45 18 Hot Note 1 G Note 2 On/Off A B C D E A B C D E F 100V Ground Neutral F H Current Rating .05 EDL Models 2A 7 4A 6 6A 6 EHL Models 4 06A Frequency-MHz .5 1 3 16 14 15 14 21 18 20 20 23 23 25 28 5 37 26 24 32 10 47 45 45 38 30 50 47 50 42 Note 1: Provision for dual European style fusing. Note 2: On/Off switch present only with "S" suffix. Resistor location for reference only. 119 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide Power Entry Module with RFI Power Line Filter for General or Medical Applications (Continued) Flange mounted version L Series Case Styles — Unfiltered Models Flange Models Case Styles — Filtered Models Flange Models 3 1 4 2 CD G H C D F B A Side View .221 5.61 .06 R 1.52 E .221 5.61 Side View E 3 1 4 2 2.201* 55.91 .020 R .508 1.122* 28.50 1.575 40.00 2.213* 56.21 G H Snap-in version Snap-In Models * +.008 -.00 A B G C D E F H +.203 -.00 Back View Recommended Panel Cutout C D Typical dimensions: Mounting Holes: .126 [3.20 ] Dia. (2) All backplate terminals: .110 [2.79 ] terminals, except for switch. Switch terminals are .187 [4.765 ] Note: Snap-in models allow front mounting only. Snap-In Models .221 5.61 Side View E Note: Metric fuse models have additional jumper from filter-to-module. CD Case Dimensions F A Side View .221 5.61 .06 R 1.52 A B G C D H E F E Part No. Flange Unfiltered Snap-in Unfiltered Flange Filtered Snap-in Filtered A (max) B ±.015 ±.381 C (max) D E F (max) (max) (max) 2.14 54.36 2.14 54.36 2.14 54.36 2.14 54.36 1.66 1.11 42.16 28.19 1.66 1.11 42.16 28.19 2.01 1.11 51.05 28.19 2.01 1.11 51.05 28.19 (1) (2) 2.201* 55.91 2.213* 56.21 1.98 1.575 2.3 50.29 40.0 58.42 1.28 2.3 — 32.51 58.42 2.3 1.98 1.575 50.29 40.0 58.42 1.28 32.51 — 2.3 58.42 .020 R .508 1.122* 28.50 * +.008 -.00 +.203 -.00 Back View Recommended Panel Cutout (1) For panel thickness of .031-.079 [0.8-2.0] (2) For panel thickness of .083-.126 [2.1-3.2] (3) For snap-in application, the 1.22 [28.5] sides of the cutout must have a .02 [.508] radius on the installation side. All backplate terminals: .110 [2.79] terminals, except for switch. Switch terminals are .187 [4.75] Note: Snap-in models allow front mounting only. 120 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com CORCOM Product Guide Power Entry Module with RFI Power Line Filter for General or Medical Applications (Continued) L Series UNFILTERED MODELS Part Number 6EL1S 6EL1SC 6EL1SM 6EL1SCM 6EL4 6EL4C 6EL4M 6EL4CM Current Rating 6A 6A 6A 6A 6A 6A 6A 6A Available Voltage Selection Position 1 1 1 1 4 4 4 4 DPST On/Off Switch • • • • Mounting Style Flange Snap-In Flange Snap-In Flange Snap-In Flange Snap-in Fuseholder Type North American North American Metric Metric North American North American Metric Metric Power Entry Modules FILTERED MODELS Part Number 2EDL1S 2EDL1SC 2EDL1SM 2EDL1SCM 2EDL4 2EDL4C 2EDL4M 2EDL4CM 4EDL1S 4EDL1SC 4EDL1SM 4EDL1SCM 4EDL4 4EDL4C 4EDL4M 4EDL4CM 6EDL1S 6EDL1SC 6EDL1SM 6EDL1SCM 6EDL4 6EDL4C 6EDL4M 6EDL4CM 6EHL1S 6EHL1SC 6EHL1SM 6EHL1SCM 6EHL4 6EHL4C 6EHL4M 6EHL4CM • Includes DPST switch Filter Type Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Linear Medical Medical Medical Medical Medical Medical Medical Medical Current Rating 2A 2A 2A 2A 2A 2A 2A 2A 4A 4A 4A 4A 4A 4A 4A 4A 6A 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Available Voltage Selection Position 1 1 1 1 4 4 4 4 1 1 1 1 4 4 4 4 1 1 1 1 4 4 4 4 1 1 1 1 4 4 4 4 DPST On/Off Switch • • • • Mounting Style Flange Snap-In Flange Snap-In Flange Snap-In Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Flange Flange Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in Fuseholder Type North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric North American North American Metric Metric • • • • • • • • • • • • 121 Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
6EHL1SCM 价格&库存

很抱歉,暂时无法提供与“6EHL1SCM”相匹配的价格&库存,您可以联系我们找货

免费人工找货