Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
High Frequency Power Line Filter or Power Entry Module
AQ Series
UL Recognized CSA Certified
3VAQ8F
6VAQ8F
AQ Series
• Low cost solution to power line noise at high frequencies • High common and differential mode performance from 10kHz to 1GHz • Available with an IEC inlet, fuseholder and switch • Suitable for applications where computers are used to process secret or confidential information
Specifications
Maximum leakage current each Line to Ground:
3A Models 6A Models
@ 120 VAC 60 Hz: @250 VAC 50 Hz: Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): Operating Frequency: Rated Current:
1.2 mA 2.3 mA
.7 mA 1.2 mA 2250 VDC 1450 VDC 250 VAC 50/60 Hz 3 or 6A
Ordering Information 3 V AQ 8 FS
S u ffix F – Fuseholder FS – Fuseholder & Switch
(F & FS on VAQ8 only)
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
Omit if none Input / Output Style 3 – Wire leads 8 – IEC inlet* (line side) Wire leads (load side) AQ Series Leakage current designation V – Standard Current Rating 3 or 6A
Electrical Schematics 3A Models
LINE LOAD
6A Models
LINE LOAD
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Available Part Numbers
3VAQ3 3VAQ8F 3VAQ8FS 6VAQ3 6VAQ8F 6VAQ8FS
*IEC 60320-1 C14 inlet mates with C13 connector
12
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
High Frequency Power Line Filter or Power Entry Module (continued)
AQ Series
Case Styles and Dimensions 3VAQ3 6VAQ3
2.46 62.3
C L
1.66 ± .015 42.1 ± .38
1
2.572 C L 65.3
RFI Power Line Filters
4.14 105.1 4.36 ± .015 111.4 ± .38 .515 13.08 #6-32
12.0 Min. 304.8
.515 13.08
#6-32
1.0 ± 0.1 25.4 ± .25
(2 x)
5.126 130.0 5.327±.015 135.3 #6-32 Thd.
12.0 Min. 304.8
(5 places)
#6-32
(2 places)
.5 ± .01 12.7 ± .25
2.0 ± .01 50.8 ± .25
1.98 40.1
3.061 77.8
.50 ± .02 12.7 ± .5 .78 19.8
3VAQ8F
5.96 152.0 5.06 ± .015 128.6 ± .38 2.35 ± .015 59.6 ± .38 .90 22.9
6VAQ8F
6.457 164 5.68 ± .01 44.3 ± .25 4.0 ± .01 102 ± .25
1.58 ±.015 40 ± .38
.958 24.3
2.48 63.0
2.328 ± .01 59 ± .35
1.125 ± .01 3.062 28.6 ± .25 77.8
12.0 Min. 305.0
.411 ref 10.4
#6-32 (6) inserts
.355 ref 9.02
12.0 Min. 305.0
.354 ±.010 ref 8.99 ± .25
#6-32 (6) inserts
.391 ± .01 9.93 ± .25
1.62 41.2 .375 ± .125 9.53 ± 3.2
.375 ± .125 9.53 ± 3.2
2.576 65.4
3VAQ8FS
5.39 ± .015 136.9 ± .38 2.35 ± .015 59.6 ± .38 1.058 26.9 .172 4.37
6VAQ8FS
7.125 181.0 6.347 ± .015 161.2 ± .38 4.0 ± .015 101.55 ± .25
#6-32 (6) inserts
.44 11.2 1.575 ± .015 40.01 ± .38 .958 24.3 2.48 63.0
2.33 ±.015 59.0 ± .38
1.52 ± .01 3.07 38.5 ± .25 77.8
.375 ± .125 9.53 ± 3.2
.411 ref 10.4
#6-32 (6) inserts
1.62 41.2
.364 9.25 12.0 Min. 304.8
1.12 ± .01 28.3 ± .25
.391 ± .01 9.93 ± .25
2.58 65.4 .375 ± .125 9.53 ± 3.2
12.0 Min. 305.0
6.30 160.0
13
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
High Frequency Power Line Filter or Power Entry Module (continued)
AQ Series
Recommended Panel Cutouts
.910 ± .005 23.11 ± .13 .855 ± .005 21.72 ± .13
.235 ± .005 R 5.969 ± .13
1.295 ± .005 32.89 ± .13
.620 ± .005 15.75 ± .13
.620 ± .005 Dia. 15.75 ± .13
Performance Data Typical Insertion Loss
Measured in closed 50 Ohm system
3VAQ
db 100 90 80 70 60 50 40 30 20 10 0
0.01 0.1 1 10 100 1000 Frequency in MHz
6VAQ
db 100 90 80 70 60 50 40 30 20 10 0
0.01 0.1 1 10 100 1000 Frequency in MHz
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
Minimum Insertion Loss
Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line)
14
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
很抱歉,暂时无法提供与“6VAQ8FS”相匹配的价格&库存,您可以联系我们找货
免费人工找货