Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
Multipurpose Power Line RFI Filter for Emission Control
V and W Series
UL Recognized CSA Certified VDE Approved
VV1 / VW1
VV6 / VW6
Both the V and W series are effective to control emissions in equipment using SCR and T2L circuits for compliance with FCC Part 15, Subpart J and EN55022, Level A, down to 150kHz
Specifications
Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: .5 mA @250 VAC 50 Hz: .82 mA Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): Operating Frequency: Rated Current: 2250 VDC 1450 VDC 250 VAC 50/60 Hz 3 to 20A*
V S er i es
• Offers an N = 3 (“T”) Line to Ground impedance to common mode and an N = 5 “Dbl. Pi”) impedance for Line to Line differential mode interference • Designed for susceptibility use when equipment impedance at RF frequencies is low
W Series
• Offers an N = 4 (“Dbl. L”) Line to Ground impedance for common mode and an N=5 (“Dbl. Pi”) impedance for Line to Line differential mode interference • Designed for use when equipment impedance at RF frequencies is high • Two stage construction provides excellent suppression at high frequencies
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
Electrical Schematics V Series
LINE LOAD
Ordering Information 20 V V 6
Input / Output Style 1 – .250 [6.3] spade terminals 6 – Threaded bolt 7 – IEC inlet* (line side) .250 [6.3] spade terminals
(load side)
W Series (3, 6 & 10A)
LINE LOAD
W Series (20A)
LINE LOAD
V or W Series Leakage current designation V – Standard Current Rating 3, 6, 10 or 20A
*IEC 60320-1 C20 inlet mates with C19 connector 20VW7, 20A model tested by Underwriters Laboratories to US and Canadian requirements and is VDE approved at 16A, 250VAC
For email, phone or live chat, please go to te.com/help corcom.com
86
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
Multipurpose Power Line RFI Filter for Emission Control (continued)
V and W Series
Available Part Numbers
3VV1 6VV1 10VV1 20VV1 20VV6 3VW1 3VW1 10VW1 20VW1 20VW6 20VW7*
Case Styles (continued) VW7
Threaded inserts
2.25 57.15
B
1
RFI Power Line Filters
.047 ± .010 1.19 ± .25 5.33 ± .025 135.38 ± .635
Case Styles V1 / W1 (3, 6 & 10A)
A
C
B
Recommended Panel Cutout
.157 3.98 Dia.
2.30 58.42
D E A
C
1.22 30.99
C L
.75 19.05
1.60 40.46
.219 R 5.56
Mounting Plane
2.12 53.85
V1 / W1 (20A)
Case Dimensions
Part No. A
B
C
EDB
3VV1, 3VW1
2.00 50.8
A
C
V6 / W6
EDB
6VV1, 6VW1 10VV1, 10VW1 20VV1, 20VW1 20VV6, 20VW6 20VW7
D
E
2.00 50.8
A
C
*20VW7, 20A model tested by Underwriters Laboratories to US and Canadian requirements and is VDE approved at 16A, 250VAC
87
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
Multipurpose Power Line RFI Filter for Emission Control (continued)
V and W Series
Performance Data Typical Insertion Loss
Measured in closed 50 Ohm system Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
3VV
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
6VV
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
10VV
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
20VV
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
3VW
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
6VW
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
10VW
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
20VW
db 100 90 80 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz
Minimum Insertion Loss
Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) 88
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
Differential Mode / Symmetrical (Line to Line)