0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CB-1021B-78

CB-1021B-78

  • 厂商:

    MACOM

  • 封装:

  • 描述:

    CB-1021B-78 - CB series CMOS IC Time Delay Relay - Tyco Electronics

  • 数据手册
  • 价格&库存
CB-1021B-78 数据手册
Catalog 1308242 Issued 3-03 P&B CB series CMOS IC Time Delay Relay • Choice of timing modes – Delay on operate – Delay on release – Interval on with or without control switch • Knob adjustable • 10A output relay with SPDT or DPDT contacts • Various models time from 0.1 sec. to 100 min. File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Timing Modes Delay on operate – Delay period begins when input voltage is applied. At the end of the delay period, the relay will operate and will not release until input voltage is removed. Reset occurs when input voltage is reapplied. INPUT VOLTAGE ON OFF TIME Contact Data @ 25°C Arrangements: 2 Form C (DPDT), except 8-pin delay on release model has 1 Form C (SPDT). Material: Silver-cadmium oxide alloy. Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @ 120VAC. Expected Mechanical Life: 10 million operations. Expected Electrical Life: 100,000 operations, min., at rated load. N.O. RELAY ON CONTACTS OFF Delay on release – Input voltage must be applied continuously to operate the internal relay. When the control switch is closed, the relay energizes. When the control switch is opened, timing begins. When timing is complete, the relay will de-energize. Time may be reset to zero during timing by closing the control switch. CONTROL SWITCH ON OFF TIME Initial Dielectric Strength Between Open Contacts: 500V rms, 60 Hz. Between All Other Conductors: 500V rms, 60 Hz. N.O. RELAY ON CONTACTS OFF Interval on (without control switch) – The relay energizes and timing begins when input voltage is applied. At the end of the time delay period the relay will de-energize. Reset is accomplished by removing, then reapplying, the input voltage. INPUT VOLTAGE ON OFF Input Data @ 25°C Voltage: 24 and 120VAC, and 12 and 24VDC. Power Requirement: AC Types: Typically less than 3 VA. DC Types: Typically less than 3 W. Transient Protection: Yes. Reverse Voltage Protection: Yes. Input Voltages & Limits @ 25°C N.O. RELAY ON CONTACTS OFF TIME Voltage Type AC DC Nominal Voltage 24 120 12 24 Minimum Voltage 20 105 11 20 Maximum Voltage 28 130 13 32 Interval on (with control switch) – Input voltage must be applied continuously to operate the internal relay. The relay energizes and timing begins when the external switch is closed. At the end of the time delay period the relay will de-energize. Reset is accomplished by opening and reclosing the control switch. CONTROL SWITCH ON OFF Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage). AC models will operate on 50 or 60 Hz. N.O. RELAY ON CONTACTS OFF TIME Environmental Data Temperature Range: Storage: -55°C to +85°C. Operating: -10°C to +55°C. Timing Specifications Timing Ranges: From 0.1 to 1.0 sec. through 10 to 100 min. Timing Adjustment: Knob adjustable. Tolerance (for AC units add ±1/2 cycle 60 Hz.): Knob Adj. Types: –0, +30% of max. specified at high end of timing range; min. specified, or less, at low end. Fixed Types: ± 10%. Res. Adj. Types: ± 10% at high end of timing range; min. specified, or less, at low end. Delta Time (for AC units add ±1 cycle 60 Hz.): ± 10%. Repeatability (for AC units add ±1 cycle 60 Hz.): ± 2%. Release Time: 60 ms, typ.; 100 ms, max. Recycle Time: 60 ms, typ.; 100 ms, max. Dimensions are shown for Mechanical Data Termination: 8- or 11-pin octal style plug. Enclosure: White plastic case. Knob adjustable types have dial scale for reference only. Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on) screw terminal sockets. 11-pin types fit either 27E123 or 27E892 (snap-on) screw terminal sockets. Weight: 6 oz. (170g) approximately. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. 1228 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Catalog 1308242 Issued 3-03 P&B Ordering Information – Authorized distributors are more likely to stock boldface items listed below. Delay on Operate Models Voltage 24VAC Time 0.1 to 10 Sec. 1.8 to 180 Sec 0.1 to 1 Sec. 0.1 to 5 Sec. 0.1 to 10 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. 1 to 10 Min. 10 to 100 Min. 0.1 to 10 Sec. 0.1 to 1 Sec. 0.1 to 10 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. Adjustment Knob Wiring Dia. 1 Part Number CB-1041B-30 CB-1042B-30 CB-1001B-70 CB-1002B-70 CB-1003B-70 CB-1004B-70 CB-1005B-70 CB-1006B-70 CB-1007B-70 CB-1047D-20 CB-1026D-30 CB-1028D-30 CB-1029D-30 CB-1030D-30 Delay on Release Models Voltage 24VAC Time 0.1 to 10 Sec. 1.8 to 180 Sec 0.1 to 10 Sec. 0.1 to 10 Sec. 0.6 to 60 Sec. 1.8 to 180 Sec. 0.1 to 10 Sec. 1.8 to 180 Sec. Time 0.1 to 10 Sec. 0.1 to 5 Sec. 0.1 to 10 Sec. 1 to 10 Min. 0.1 to 5 Sec. 1.8 to 180 Sec. Adjustment Knob Wiring Dia. 3 3 5 3 3 3 Part Number CB-1045B-38 CB-1046B-38 CB-1021B-78 CB-1022B-78 CB-1023B-78 CB-1024B-78 CB-1038D-38 CB-1039D-38 Part Number CB-1043B-39 CB-1011B-79 CB-1014B-79 CB-1018B-79 CB-1034D-39 CB-1036D-39 120VAC Knob 120VAC Knob 1 24VDC Knob 12VDC 24VDC Knob Knob 1 1 Interval on Models Voltage 24VAC 120VAC 24VDC Adjustment Knob Knob Knob Wiring Dia. 1 1 1 1 1 Outline Dimensions ➛ 2.406 MAX. (61.1) ➛ Wiring Diagrams - Bottom Views (pins numbered clockwise from keyway) EXTERNAL CONTROL SWITCH* EXTERNAL CONTROL SWITCH* ➛ ➛ ➛ ➛ ➛ + _ INPUT (DC POLARITY INDICATED)** Fig. 1 8 Pin * If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: A dry circuit switch is recommended. A “dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly. ** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”. Dimensions are shown for reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. ➛ ➛ + _ CONTINUOUS SUPPLY INPUT (DC POLARITY INDICATED)** Fig. 3 11 Pin ➛ ➛ ➛ ➛ .60 (15.2) ➛ 2.937 MAX. (74.6) .56 (14.2) 1.781 MAX. (45.2) ➛ ➛ ➛ ➛ + _ CONTINUOUS SUPPLY INPUT (DC POLARITY INDICATED)** Fig. 5 8 Pin Specifications and availability subject to change. www.tycoelectronics.com Technical support: 1229 Refer to inside back cover.
CB-1021B-78 价格&库存

很抱歉,暂时无法提供与“CB-1021B-78”相匹配的价格&库存,您可以联系我们找货

免费人工找货