Raychem FT600 Series Overcurrent Fuse
New surface-mount fuse products for overcurrent protection of communications equipment
Benefits:
• When combined with a SiBar™ overvoltage protection device, assists equipment in meeting regulatory standards with no additional series components • Improved temperature rise performance over other similar SMT fuse devices under sneak current testing • High density placement in multi-port system designs
Features:
• The lightning robust surface-mount fuse offers overcurrent protection from power faults • Designed to assist equipment in complying with telecom specifications including UL60950, FCC Part 68, and Telcordia GR-1089 • Small footprint and low resistance • Low profile
Target Applications:
• xDSL and ADSL linecards and modems • T1/E1 systems • Twisted pair telecom ports requiring Telcordia GR-1089, UL60950 and FCC Part 68 compliance
Interrupt Voltage and Current Ratings
Part Number FT600-0500 FT600-1250 FT600-2000 Ampere Rating (A) 0.50 1.25 2.00 Voltage Rating (V) 250 250 250 Typical Resistance ( Ω) 0.5 0.1 0.05 Typical I2t (A2s)* 1 16 18
The FTxxxx devices are designed to carry 100% of rated current for 4 hours minimum and 250% of rated current for 1 second minimum, 120 seconds maximum. Resistance measured at 10% of rated current. *I2t is calculated at 10 ms or less.
Power Cross
GR-1089 1000Vac, 5A, 0.5sec FT600-0500 FT600-1250 FT600-2000 ✓ ✓
GR-1089 600Vac, 60A, 5sec ✓ ✓
UL60950 600Vac, 40A, 1.5sec ✓ ✓ ✓
GR-1089/UL60950 600Vac, 7A, 5sec ✓ ✓ ✓
GR-1089/UL60950 600Vac, 2.2A, 30min ✓ ✓ ✓
GR-1089 277Vac, 25A, 15min ✓ ✓ ✓
UL60950 120Vac, 25A, 30min ✓ ✓ ✓
Note: FT600-1250 and FT600-2000 are designed to assist equipment in complying with Telcordia GR-1089 specifications. In-circuit testing is strongly recommended.
Lightning Surge
Telcordia GR-1089 Surge Voltage (Vpk) Wave Form (µs) Surge Current (A) Repetitions (each polarity) FT600-0500 FT600-1250 FT600-2000 FCC Part 68 Surge Voltage (Vpk) Short Circuit Wave Form (µs) Surge Current (A) Repetitions (each polarity) FT600-0500 FT600-1250 FT600-2000
First Level Test 1 600 10x1000 100 25 ✓ ✓ Type A Metallic 800 10x560 100 1 Fuse open ✓ ✓
First Level Test 2 1000 10x360 100 25 ✓ ✓
First Level Test 3 1000 10x1000 100 25 ✓ ✓ Type A Longitudinal 1500 10x160 200 1 Fuse open ✓ ✓
First Level Test 4 2500 2x10 500 10 ✓ ✓ Type B Metallic 1000 5x320 25 1 ✓ ✓ ✓
First Level Test 5 1000 10x360 25 5 ✓ ✓
Second Level Test 1 5000 2x10 500 1 ✓ ✓ Type B Longitudinal 1500 5x320 37.5 1 ✓ ✓ ✓
The FT600-0500, FT600-1250 and FT600-2000 are designed to meet the FCC Part 68 lightning surge requirements. Note that Type A tests allow for an overcurrent protection component to fuse open during the surge.
Product Dimensions
A B C
Dimensions in millimeters (inches)
A (Max.) 10.5 (0.413) B (Max.) 3.4 (0.133) C (Max.) 3.4 (0.133)
Termination material Body material Termination solderability Solder heat withstand Solvent resistance Storage temperature Storage humidity
Details Silver-plated brass Ceramic Per IEC-60127-4 Per MIL-STD-202, Method 210, Test Condition J Per MIL-STD-202F, Method 215J -40/+85°C Per MIL-STD-202F, Method 106F
FT600 Series Fuses
Typical Time-to-Open Characteristics (at 25˚ C) Thermal Derating Curve
130
120
PERCENT OF CURRENT RATING
110
100
90
80
70 -70 -50 -30 -10 10 30 50 70 90 110 130 AMBIENT TEMPERATURE (°C)
Solder Reflow Recommendations
300 Preheating Soldering Cooling
250
Temperature°(°C) Temperature ( C)
200
Solder Reflow • Recommended reflow methods: IR, vapor phase oven, hot air oven. • Devices can be cleaned using standard industry methods and solvents.
Ordering Information
Part numbers FT600-0500-2 FT600-1250-2 FT600-2000-2 2,500/reel 10,000/box
150
Devices per reel Standard package
100
Note: The -2 designates tape and reel, the package style for this product.
50
0
30 to 90 10 to 20 Time(s) Time(s)
120
Recommended Pad Layout
The dimensions in the table below provide the recommended pad layout for each FT600 device.
D
C B
Dimensions in millimeters (inches)
A 12.6 (0.496) B 4.0 (0.157) C 3.7 (0.145) D 5.2 (0.204)
Agency Recognitions
UL CSA File # E197536 Pending
©2002 Tyco Electronics Corporation. Printed in USA. RCP0049.1102.1000
A
Worldwide Headquarters
308 Constitution Drive, MS R21/2A Menlo Park, CA USA 94025-1164 Tel (800) 227-7040 (650) 361-6900 Fax (650) 361-2508
Japan Tel 81-44-900-5110 Fax 81-44-900-5140 Asia Pacific Tel 852-2738-3401 Fax 852-2735-1185
Europe Tel 32/16351714 Fax 32/16351727
www.tycopowercomponents.com www.circuitprotection.com.hk (Chinese) www.raychem.com/go/jpn/polyswitch (Japanese)
SiBar is a trademark of Tyco Electronics Corporation. All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco Electronics makes no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Electronics’ only obligations are those in the Company’s Standard Terms and Conditions of Sale for this product, and in no case will Tyco Electronics be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications are subject to change without notice. In addition, Tyco Electronics reserves the right to make changes-without notification to Buyer-to materials or processing that do not affect compliance with any applicable specification.
很抱歉,暂时无法提供与“FT600-2000”相匹配的价格&库存,您可以联系我们找货
免费人工找货