Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
The CHAMELEON Adaptable Module for DC Applications
P Series
EN 60 950
UL Recognized CSA Certified TUV Certified
P S er i es
• Full flexibility of design in the most compact package • General purpose designed for DC applications • Mates with a standard MOLEX* connector (HCS Series) which prevents accidental connection to AC Power
Specifications
Hipot rating (one minute): Line to Ground: LIne to Line: Rated Voltage (max): Rated Current: Fuseholder*: Terminals: 2250 VDC 1450 VDC 80 VDC 3 to 10A .25 x 1.25” or 5 x 20 mm .187 x .032 [4.8 x .81] terminal tabs
Ordering Information P S 0 0 0 D D3D
Shield Options D = Complete Shield
(DC Version)
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45
4
DC Filters
Current Rating 3 = 3A 6 = 6A X = 10A Filter Type D = DC version Fuse Options D = Dual fuse S = Single fuse Input Voltage Select 0 = Single voltage Switch Options 0 = No switch Extender Options 0 = None Mounting Style E = Mounting ears S = Snap-in
Electrical Schematic
LINE LOAD
Available Part Numbers
PE000DD3D PE000DD6D PE000DDXD PE000SD3D PE000SD6D PE000SDXD PS000DD3D PS000DD6D PS000DDXD PS000SD3D PS000SD6D PS000SDXD
223
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
The CHAMELEON Adaptable Module for DC Applications (continued)
P Series
Case Styles PE
Part No. PE
C
Case Dimensions
A
B
C
D
E
F
PS
Recommended Panel Cutouts
F A B
min. Radius Ground connection
.06 R Max. 1.52
.07 1.78
PS
External Edge (1) .020 R Min. .508
E
C
D
Note: The external edges (installation side) on the "D" sides of the cutout should have a minimum .020" radius. For optimal retention against extraction, the corresponding inner edge should be sharp, without paint or coatings. Edge coatings, including anodization are also discouraged for good shield contact.
B A
Performance Data Accessories
Red Black
Minimum Insertion Loss
Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground)
GA210 – (shown above) Pre-assembled connector housing with two 36” long 18 gauge wires to mate with P Series DC filters MOLEX Part Numbers: 03-12-1026 18-12-1222 DC Connector housing for P Series Female terminals (2 per connector)
Differential Mode / Symmetrical (Line to Line) 224
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
For email, phone or live chat, please go to te.com/help corcom.com
很抱歉,暂时无法提供与“PS000SD3D”相匹配的价格&库存,您可以联系我们找货
免费人工找货