Power PCB Relay RX
1 pole (12 or 16 A) or 2 pole (8 A) DC or AC-coil
• • • • • •
Features
1 C/O or 1 N/O or 2 C/O contacts DC- or AC-coil 4 kV / 8 mm coil-contact Reinforced insulation (protection class II) Height 15.7 mm transparent cover optional
Applications Domestic appliances, heating control, emergency lighting
VZ
Contact data
Configuration Type of contact Rated current Rated voltage / max.breaking voltage AC Maximum breaking capacity AC Contact material 1 C/O or 1 N/O 12 A single contact
Approvals in process
2 C/O
1pole
16 A 8A 250 Vac / 440 Vac 3000 VA 4000 VA 2000 VA AgNi 90/10
Coil data
Nominal voltage Nominal coil power Operate category
DC coil AC coil DC coil AC coil
5...110 Vdc 24...230 Vac 500 mW 0.75 VA 2
Coil versions, DC-coil Coil Nominal Pull-in Release Maximum Coil code voltage voltage voltage voltage resistance Vdc Vdc Vdc Vdc c 005 5 3.5 0.5 9.8 50+5% 006 6 4.2 0.6 11.8 68+5% 012 12 8.4 1.2 23.5 274+5% 024 24 16.8 2.4 47.0 1095+5% 048 48 33.6 4.8 94.1 4380+5% 060 60 42.0 6.0 117.6 6845+5% 110 110 77.0 11.0 215.6 23010+5% All figures are given for coil without preenergization, at ambient temperature +20°C Other coil voltages on request
Edition: 10/2003
Coil current mA 100.0 87.7 43.8 21.9 11.0 8.8 4.8
Rights to change data / design reserved
Power PCB Relay RX
1 pole (12 or 16 A) or 2 pole (8 A) DC or AC-coil
Coil versions, AC-coil Coil Nominal Pull-in Release Maximum Coil code voltage voltage voltage voltage resistance Vac Vac Vac Vac c 524 24 18.0 3.6 36.0 350+10% 615 115 86.3 17.3 172.5 8100+15% 730 230 172.5 34.5 345.0 32500+15% All figures are given for coil without preenergization, at ambient temperature +20°C
Coil current mA 31.6 6.6 3.2
Insulation
Dielectric strength
Clearance / creepage Insulation to IEC 60664 Voltage rating Pollution degree Overvoltage category Insulation dimensions coil-contacts contact-contact across open contacts Tracking resistance of relay base
coil-contacts open contact circuit
4000 Vrms 1000 Vrms 8 / 8 mm 250 V 3 III reinforced insulation basic / functional insulation micro-disconnection CTI 250
Rights to change data / design reserved
Edition: 10/2003
Flammability class according to UL 94 standard / transparent cover V-0 / HB Coil insulation system according to UL 1446 Class F Min. ambient temperature -40 °C Max. ambient temperature / mounting distance 1pole 2pole DC-coil 85 °C 1) / 2.5 mm 70 °C / 2.5 mm AC-coil 70 °C / 2.5 mm 70 °C / 5 mm Mechanical life DC-coil >5x106 operations AC-coil >1x106 operations Max. switching rate at rated- / minimum load 6 min-1 / 600 min-1 Operate- / release time DC-coil typ. 7 / 2 ms Bounce time N/O contact/N/C contact typ. 1 / 3 ms Vibration resistance N/O 20 g, 10...150 Hz Shock resistance (destruction) 100 g Category of protection (IEC 61810) RT II - flux proof, RT III - wash tight 2) Relay weight 13 g Packaging unit 500 pcs. 1) version with transparent cover: 70°C 2) version with transparent cover: RTII only
Other data
Power PCB Relay RX
1 pole (12 or 16 A) or 2 pole (8 A) DC or AC-coil
Dimensions
Dimensions in mm
S0272-AA
PCB layout / terminal assignment
1 pole 12 A 1 pole 16 A 2 pole 8 A
S0418-BB
S0418-BA
S0418-BA
S0163-BG
S0163-BE
S0163-BJ
View on solder pins Dimensions in mm *) With the recommended PCB hole sizes a grid pattern from 2.5 mm to 2.54 mm can be used.
S0163-BH
S0163-BF
Edition: 10/2003
Rights to change data / design reserved
Power PCB Relay RX
1 pole (12 or 16 A) or 2 pole (8 A) DC or AC-coil
Rights to change data / design reserved
Edition: 10/2003
很抱歉,暂时无法提供与“RXD14110C”相匹配的价格&库存,您可以联系我们找货
免费人工找货