Tyco / Electronics
Raychem Circuit Protection
308 Constitution Drive Menlo Park, CA 94025-1164 Phone: 800-227-4856 Fax: 800-227-4866
PolySwitch® PTC Devices
Overcurrent Protection Device
PRODUCT: SRP350
DOCUMENT: SCD 21791 PCN: 715141 REV LETTER: G REV DATE: JULY 25, 2002 PAGE NO.: 1 OF 1
Specification Status: RELEASED
Electrical Rating
Voltage: 30V MAX Current: 100A MAX Leads: Nickel: 0.125 mm Nominal Thickness Tape: Polyester Marking:
Manufacturer's Mark
350
Part Identification Lot Identification
TABLE I. DIMENSIONS:
mm: in*: A B MIN MAX MIN MAX 28.4 31.8 13.0 13.5 (1.12) (1.25) (0.51) (0.53) *Rounded off approximation C MIN 0.5 (0.02) MAX 1.1 (0.04) MIN 6.3 (0.25) D MAX 8.9 (0.35) MIN 6.3 (0.25) E MAX 8.9 (0.35) MIN 6.0 (0.24) F MAX 6.6 (0.26) MIN --G MAX ---
TABLE II. PERFORMANCE RATINGS:
I HOLD CURRENT TRIP LIMITS TIME TO TRIP REFERENCE RESISTANCE ONE-HOUR POST-TRIP RESISTANCE OHMS AT 20°C MIN MAX 0.017 0.050 TRIPPEDSTATE POWER DISSIPATION WATTS AT 20°C, 15V TYP MAX 1.9 2.5
AMPS 20°C HOLD 3.5
AMPS AMPS AMPS AMPS SECONDS AT OHMS AT 0°C AT 20°C AT 60°C AT 80°C 20°C, 20 A AT 20°C HOLD TRIP HOLD TRIP HOLD TRIP HOLD TRIP TYP MAX MIN MAX 4.3 7.2 3.5 6.3 2.5 4.4 --1.5 3.0 0.017 0.031
Recognitions: Reference Documents: Precedence: Effectivity: CAUTION:
UL/TUV approved PS300 This specification takes precedence over documents referenced herein. Reference documents shall be the issue in effect on the date of invitation for bid. Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame.