T92P7D22-24

T92P7D22-24

  • 厂商:

    MACOM

  • 封装:

  • 描述:

    T92P7D22-24 - 2 pole 30 A, 2 CO or 2 NO contacts - Tyco Electronics

  • 详情介绍
  • 数据手册
  • 价格&库存
T92P7D22-24 数据手册
General Purpose Relays SCHRACK Power Relay T92 n n n n n n n 2 pole 30 A, 2 CO or 2 NO contacts High switching capacity up 30 A / 400 VAC DC- or AC coil 4 kV / 8 mm coil-contact Insulation to VDE 0631 and VDE 0700 PCB- or quick connect terminals or chassis mount Adapter for DIN-rail mounting T92_group Applications Power supplies, heating & ventilation, control equipment Approvals V REG.-Nr.of5386, U E22575, C LR15734 Technical data approved types on request Contact data Contact configuration 2 NO contacts 2 CO contacts Contact set single contact Type of interruption micro disconnection Rated voltage / max. switching voltage AC 400 / 600 VAC Rated current NO contact (PCB / flange mount) 30 / 20 A 30 / 20 A NC contact 3A Maximum breaking capacity AC, NO / NC contact 12 kVA 12 / 1.2 kVA Contact material AgCdO Minimum contact load 500mA, 12V Rated frequency of operation with / without load 7 min-1 / 300 min-1 Operate- / release time (including bounce) 25 / 25 ms Contact ratings Type UL 508 T92 AgCdO, T92 AgCdO, T92 AgCdO T92 AgCdO IEC 61810 T92 AgCdO, T92 AgCdO, T92 AgCdO, T92 AgCdO, T92 AgCdO, T92 AgCdO, T92 AgCdO, T92 AgCdO, DC coil AC coil ContactLoad CO CO CO CO CO CO CO CO NO NO NO NO 30 A 30 A 30 A 20 A / / / / 3A 3A 3A 3A Ambient temp. [°C] 277 VAC, resistive 277 VAC, resistive 277 VAC, gen. purp. 28 VDC, resisitive 25°C 25°C 25°C 25°C 85°C 65°C 85°C 65°C 85°C 65°C 85°C 65°C Cycles 250x103 100x103 100x103 100x103 30x103 30x103 30x103 30x103 100x103 100x103 100x103 100x103 PCB, DC coil PCB, AC coil flange, DC coil flange, AC coil PCB, DC coil PCB, AC coil flange, DC coil flange, AC coil 30 A/ 3 A, 400 VAC, cosϕ=1 30 A/ 3 A, 400 VAC, cosϕ=1 20 A/ 3 A, 400 VAC, cosϕ=1 20 A/ 3 A, 400 VAC, cosϕ=1 30 A 400 VAC, cosϕ=1 30 A 400 VAC, cosϕ=1 20 A 400 VAC, cosϕ=1 20 A 400 VAC, cosϕ=1 Coil data Rated coil voltage range DC coil AC coil Operative range to IEC 61810 5...110 VDC 24...240 VAC 1 1 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays SCHRACK Power Relay T92 (Continued) Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm mW 12 12 9.0 1.2 86+10% 1674 24 24 18.0 2.4 350+10% 1646 48 48 36.0 4.8 1390+10% 1658 110 110 83.0 11.0 7255+10% 1668 All figures are given for coil without preenergization, at ambient temperature +23°C Other coil voltages on request Coil versions, AC-coil 50 / 60 Hz Coil Rated Frequ. Operate Release DC-coil Rated coil code voltage voltage voltage resistance power VAC Hz VAC VAC Ohm VA 24 24 60 19.2 2.4 37+10% 4 120 110 / 120 50 / 60 96.0 12.0 950+10% 4 240 220 / 240 50 / 60 192.0 24.0 3800+10% 4 All figures are given for coil without preenergization, at ambient temperature +23°C Other coil voltages on request Insulation Insulation resistance coil-contact circuit Dielectric strength coil-contact circuit open contact circuit adjacent contact circuits Clearance / creepage coil-contact circuit Tracking index of relay base Insulation to IEC 61810-1 Type of insulation coil-contact circuit open contact circuit adjacent contact circuits Rated insulation voltage Pollution degree Rated voltage system Overvoltage category < 109 Ohms 4000 Vrms 1500 Vrms 2000 Vrms W 5.5 / 8 mm PTI 250 basic micro disconnection basic 250 V 3 250 V III PCB layout / terminal assignment Bottom view on solder pins Other data Mechanical endurance >5x106 cycles Material RoHS - Directive 2002/95/EC compliant per product date code 0509 Environment Ambient temperature range DC-coil -40...+85°C AC-coil -40...+65°C Vibration resistance (function) NO / NC contact 1.65 mm, 10...55 Hz Shock resistance (function) NO / NC contact 10 g, 11 ms half sine Shock resistance (destruction) 100 g, 11 ms half sine Category of protection RT I (dust protected) RT III (wash tight) Processing Relay weight 86 g Packaging unit 30 pcs PCB version S0262-AA Dimensions PCB version S0262-AI Only necessary terminals are present on 2 NO models. S0292-A 2 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays SCHRACK Power Relay T92 (Continued) Dimensions Flange mount M4 screw terminals S0495-A S0293-A Only necessary terminals are present on 2 NO models. Product key Type Typical product key T92 P 7 A 2 2 -24 T92 Power relay T92 Enclosure P dust protected S wash tight (PCB version only) Contact configuration 7 2 NO contacts (2 form A) 11 2 CO contacts (2 form C) Coil version A AC-coil 50/60 Hz D DC-coil Mounting 1 PCB-version 2 Flange mount, 6.35 mm quick connect terminals for contacts and coil 5 M4 scew terminals (requires enclosure P and contact configuration 7, UL/CSA approved only) Contact material 2 AgCdO Coil Coil code: please refer to coil versions table Other types on request Product key T92P11A22-24 T92P11A22-240 T92P7A22-120 T92P7A22-240 T92P7D12-12 T92P7D22-12 T92P7D22-24 T92S11A12-240 T92S11A22-240 T92S11D12-24 T92S7A12-240 T92S7A22-240 T92S7D12-24 T92S7D22-24 Version dust-proof Mounting flange mount Cont.configuration 2 CO contacts 2 NO contacts Coil AC-coil pcb-version flange mount wash tight pcb-version flange mount pcb-version flange mount pcb-version flange mount 2 CO contacts 2 NO contacts DC-coil AC-coil DC-coil AC-coil DC-coil Coil 24 VAC 240 VAC 120 VAC 240 VAC 12 VDC 24 VDC 240 VAC 24 VDC 240 VAC 24 VDC Part number 4-1393211-3 4-1393211-4 5-1393211-7 6-1393211-2 6-1393211-5 6-1393211-9 7-1393211-1 8-1393211-2 8-1393211-7 9-1393211-0 9-1393211-9 1393212-5 1-1393212-0 1-1393212-7 3 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change.
T92P7D22-24
物料型号: - T92P11A22-24:防尘型,表面安装,2常开接触点,交流线圈,24VAC。 - T92P11A22-240:防尘型,表面安装,2常开接触点,交流线圈,240VAC。 - T92P7A22-120:防尘型,表面安装,2常闭接触点,交流线圈,120VAC。 - T92P7A22-240:防尘型,表面安装,2常闭接触点,交流线圈,240VAC。 - T92P7D12-12:防尘型,表面安装,2常闭接触点,直流线圈,12VDC。 - T92P7D22-12:防尘型,表面安装,2常开接触点,直流线圈,12VDC。 - T92S11A12-240:防水型,表面安装,2常开接触点,交流线圈,240VAC。 - T92S11A22-240:防水型,表面安装,2常开接触点,交流线圈,240VAC。 - T92S11D12-24:防水型,表面安装,2常开接触点,直流线圈,24VDC。 - T92S7A12-240:防水型,表面安装,2常闭接触点,交流线圈,240VAC。 - T92S7A22-240:防水型,表面安装,2常闭接触点,交流线圈,240VAC。 - T92S7D12-24:防水型,表面安装,2常闭接触点,直流线圈,24VDC。 - T92S7D22-24:防水型,表面安装,2常闭接触点,直流线圈,24VDC。

器件简介: Power Relay T92是一款通用继电器,具有2个接点,可以是2常开(2NO)或2常闭(2CO)接触点。它支持高达30A/400VAC的高开关容量,可以是直流或交流线圈驱动,具有4kV/8mm的线圈接触绝缘,符合VDE 0631和VDE 0700标准。

引脚分配: - 2NO接触点配置为单接触点。 - 2CO接触点配置为微断开。

参数特性: - 额定电压/最大切换电压AC:400/600VAC。 - 额定电流:NO接触点(PCB/法兰安装)为30/20A,NC接触点为3A。 - 最大断开能力AC,NO/NC接触点为12kVA/12/1.2kVA。 - 接触材料为AgCdO。 - 最小接触负载为500mA, 12V。 - 带/不带负载的额定操作频率为7 min1/300 min'。 - 操作/释放时间(包括抖动)为25/25 ms。

功能详解: 该继电器适用于电源供应、供暖通风和控制设备等应用。

应用信息: 适用于电源供应、供暖通风和控制设备等。