DC SOLID STATE RELAYS
SOLID STATE RELAYS
TS SERIES
50 TO 250 mA
MEETS MIL-R-28750/5,6, & 7
CONTROL SOURCE
1 7
3 5 +
LOAD DC SUPPLY +
CONTROL SOURCE
1 7
3 5
LOAD AC OR ± DC SUPPLY
TERMINAL VIEW
FEATURES ■ ■ ■ ■
Hermetically sealed TO-5 package Transformer coupled High speed switching TS5-1Y switches AC or DC
INPUT CHARACTERISTICS
INPUT VOLTAGE RANGE
4.0 – 7.0 Vdc
MAXIMUM TURN-ON VOLTAGE
5.0 Vdc
MINIMUM TURN-OFF VOLTAGE
1.0 Vdc
I/O DIELECTRIC
1000 Vac pk-pk
OUTPUT CHARACTERISTICS
MAX. OUTPUT CURRENT (CONTINUOUS, 25°C)
50 mAac or mAdc (TS5-1Y) 250 mAdc (TS6-1Y) 100 mAdc (TS7-1Y)
MAX. OUTPUT VOLTAGE
40 Vac or Vdc (TS5-1Y) 40 Vdc (TS6-1Y) 250 Vdc (TS7-1Y)
MAX. ON-RESISTANCE
5 ohms (TS5-1Y)
TURN-ON TIME TURN-OFF TIME
10 µsec.
15 µsec.
ENVIRONMENTAL CHARACTERISTICS
SHOCK
1500 G’s, 0.5 ms.
VIBRATION
100 G’s, 10 to 2000 Hz
OPERATING AMBIENT TEMPERATURE
-55 to +125°C
46
Tyco Electronics Corporation www.tycoelectronics.com 800-522-6752 (U.S.A.) or 717-564-0100 Specifications subject to change. CII and TYCO are trademarks. ©2003 by Tyco Electronics Corporation
DC SOLID STATE RELAYS
30
–125°C
–55°C
20
5 Vdc INPUT RATED CURRENT 4 Vdc INPUT
OUTPUT CURRENT (mA)
OUTPUT CURRENT (mA)
OUTPUT CURRENT (mA)
10 9 8 7 6 5 4 3 2
50 40 30 20
40 30
4 Vdc INPUT
20
1
10
10
-60 -40 -20 0 20 40 60 80 100 120 140
-60 -40 -20 0 20 40 60 80 100 120 140
-60 -40 -20 0 20 40 60 80 100 120 140
AMBIENT TEMPERATURE (°C)
AMBIENT TEMPERATURE (°C)
AMBIENT TEMPERATURE (°C)
TS5-1Y
TS6-1Y OUTPUT CURRENT VS. INPUT CONTROL VOLTAGE AND AMBIENT TEMPERATURE
TS7-1Y
–125°C
–55°C
100 90 80 70 60 50
5 Vdc INPUT RATED CURRENT 4 Vdc INPUT
–125°C
100 90 80 70 60 50 40
400 300
400 300
SOLID STATE RELAYS
7 Vdc INPUT
–55°C
6 Vdc INPUT
200
7 Vdc INPUT 6 Vdc INPUT
200
100 90 80 70 60
7 Vdc INPUT 6 Vdc INPUT 5 Vdc INPUT RATED CURRENT
EW
.370 DIA MAX (9.40) .335 DIA MAX (8.51) .275 MAX (12.70)
.017 DIA (0.43) .031
.50 MIN (12.70)
45°
.032 (REF) (0.81) .100 (2.54) .200 (5.08)
TS5/TS6/TS7
NOTES: 1) Reversing polarity of input (or output except for TS5-1) may cause permanent damage. 2) Input must be a step function. Rise or fall time, as applicable, not to exceed 100 µsec. 3) Inductive loads must be diode suppressed. 4) For any control voltage, the maximum load current shown on graphs must not be exceeded. Attempting to draw currents in excess of those specified on graphs can cause permanent damage.
47
Tyco Electronics Corporation www.tycoelectronics.com 800-522-6752 (U.S.A.) or 717-564-0100 Specifications subject to change. CII and TYCO are trademarks. ©2003 by Tyco Electronics Corporation