0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
电子发烧友
开通电子发烧友VIP会员 尊享10大特权
海量资料免费下载
精品直播免费看
优质内容免费畅学
课程9折专享价
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
WSYN

WSYN

  • 厂商:

    MACOM

  • 封装:

  • 描述:

    WSYN - Paralleling Relays - Tyco Electronics

  • 数据手册
  • 价格&库存
WSYN 数据手册
Paralleling Relays WILMAR™ Protective Relays – WSYN Series TERMINAL STRIPS #6 - 32 SCREWS Function: 25 • ANSI/IEEE C37.90-1978 • UL file No. E58048 • CSA file No. LR61158 Operation: A. The output relay will energize when all three of the following conditions are met: 1. Voltage differential is below the preset value. 2. Phase angle is below the preset value. 3. Frequency differential is below the preset value. B. The relay is also provided with a "Double Dead Bus" feature: When the voltage on either one of the sensing inputs is below 15-25% of nominal, (Dead Bus Condition), the output relay will energize to permit paralleling. 12 4/ 2 15 / 3 5 4 3/16 3 1/ 2 7 / 16 4 1 /4 5 2 23 / 3 5 When both sensing voltage are below 15-25% of nominal, the output relay will not energize. 13/ 64" D IA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. PART NUMBER SELECTION Sample Part No. Type: WSYN - Synchro Check Frequency Hz 50 60 400 WSYN-50-120-12DC-A PRODUCT SPECIFICATIONS Part Number Sensing Voltage ................................... WSYN Series Single Phase, see Part Number Selection Sensing Voltage VAC ( ± 10%) 120 400 200 416 208 440 220 460 230 480 240 525 380 575 Control Voltage ( ± 20%) 12DC 120AC 24DC 230AC 48DC 380AC 125DC 460AC Options A = two normal open contacts B = two normally closed contacts H = Contacts rated 3 amp at 125 VDC P = Transient Protection Transient Protection - All voltage relays will withstand momentary voltage surges of twice the nominal rated input voltage (standard). Control Voltage .................................... See Part Number Selection Voltage Differential Adjust Range ....... 4% to 10% of nominal voltage Phase Angle Adjust Range .................. 4 to 10 electrical degrees Frequency Differential Adjust Range Operating Temperature ........................ 0.2 Hz to 0.5 Hz -20o C to +50 oC Contact Ratings .................................... 5 amp resistive at 120 VAC or 28Vdc Output Contacts ................................... One set N.O., one set N.C. Notes: 1. Remove black cover screws to gain access to the adjustment potentiometers. 2. Clockwise rotation increases the trip differential setting. 3. Calibration terminals (11) (12) must be connected together to disable the phase angle detector when setting the frequency difference trip point. Once it is set, the connection must be removed. 38 Tyco Electronics / www.tycoelectronics.com / Factory Direct Technical Support: 800-253-4560, ext. 2023 (U.S., Canada, Mexico) or 805-220-2020, ext. 2023 (International)

很抱歉,暂时无法提供与“WSYN”相匹配的价格&库存,您可以联系我们找货

免费人工找货