Kotron® Model 82 CE RF Level Transmitter
DESCRIPTION
The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art surface mount technology in an encapsulated (potted) module for a stable, accurate measurement in a wide range of materials.
FEATURES
• 4–20 mA isolated output signal (reversed 20–4 mA output optional) • Utilizes a 24 VDC current loop for power source and signal transmission • 120/240 VAC option available for four-wire applications • Minimum span 50 pF • Maximum span 4000 pF • Integral metering points to allow the local measurement of 4–20 mA loop current without breaking the two-wire circuit loop • Power indicator LED varies in brightness with level changes • ±0.25% repeatability • Liquid-liquid interface level measurement • FM, CSA, and ATEX listed intrinsically safe when used in conjunction with an approved barrier • CSA explosion proof designs • Available with a full range of rigid and flexible sensing probes to 5000 psig (345 bar) and +1000° F (+538° C) • Input voltage of 14 to 40 VDC at transmitter terminals • Two-wire, integrally mounted units meet CE requirements for RFI/EMI noise immunity • Clean or dirty liquids • Viscous liquids • Light slurries • High temperature liquids • Hydrocarbons & solvents • Acids & corrosive liquids • Food & beverage
APPLICATIONS
• Continuous level monitoring
TECHNOLOGY
The amount of capacitance developed in any vessel is determined by the size (surface area) of the probe, the distance from the probe to its ground reference (e.g. tank wall), and the dielectric of the medium being measured. If the probe’s mounting position is fixed and the dielectric value of the medium is constant, then the amount of capacitance developed becomes dependent on the media in contact with the probe. As media rises and falls in the tank, the amount of capacitance developed between the sensing probe and the ground also rises and falls. This change in capacitance is converted into a proportional 4–20 mA output signal.
ELECTRICAL
Supply Voltage Current Line Variation Ambient Temperature Zero Range Span Range Output Linearity
SPECIFICATIONS
24 VDC, (14–40 VDC) 120/240 VAC, 50–60 Hz, (+10/-15%) 38 mA maximum Less than ±.10%/volt, for voltages between 14–40 VDC -40° to +160° F (-40 to +70° C) ➀ 1000 pF (max.), 0 pF (min.) 4000 pF (max.), 50 pF (min.) 50–500 pF ±1% of span 501–1500 pF ±2% of span 1501–4000 pF ±1% of span Less than 0.1 second ±0.25% 4000 pF span: Less than 0.035%/° F (0.063%/° C) 1000 pF span: Less than 0.025%/° F (0.045%/° C) 50 pF span: Less than 0.075%/° F (0.135%/° C)
Response Time Repeatability Temperature Coefficient of Output -40° to +160° F (-40° to +70° C)
➀ Consult factory for higher temperatures on remote mounted transmitter
2
MODEL
STANDARD
NUMBER
PRESSURE
Models available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP) BASIC
082 82 CE transmitter
HOUSING
8 FM/CSA/CENELEC EEx ia, aluminum 3⁄4" NPT dual conduit
FUNCTION/INPUT POWER
0 1 3 4 Four-wire, 120 VAC ➀ Four-wire, 240 VAC ➀ Two-wire, 24 VDC Nominal (14 to 40 VDC), FM, CSA Two-wire, 24 VDC Nominal (14 to 40 VDC), ATEX Intrinsically Safe
METER
0 1 None Analog meter (Not FM/CSA approved)
OUTPUT SIGNAL
3 4 Standard 4–20 mA Reversed 20–4 mA ➁ ➂ (Not CSA approved)
MOUNTING CONFIGURATION
00 04 10 14 Integral, NEMA 4X/7/9 aluminum housing Integral, NEMA 4X/7/9 316 stainless steel housing ➂ ➅ Remote, NEMA 4X/7/9 aluminum housing ➃ ➄ Remote, NEMA 4X/7/9 316 stainless steel housing ➂ ➃ ➄ ➅
PROBE ASSEMBLIES ➆
A full range of rigid and flexible probes for conductive and non-conductive process media is available. For further information on probe assemblies, please refer to bulletin 50-125. ➀ Not available with mounting codes 04 and 14. ➁ Consult factory on reversed output model. ➂ Not available with function/input power codes 0 and 1. ➃ Remote units supplied with separate probe and transmitter housing, 20 feet (6 meters) of cable and transmitter housing bracket. ➄ Remote units up to 40 feet (12 meters) with special cable, order cable part number 009-8222-001. ➅ Not available with Meter option code 1. ➆ Delivery is ESP only if Model 082 and probe selected are both ESP.
0
8
2
4
3
DIMENSIONAL
INCHES (mm)
SPECIFICATIONS
4.63 (118) Dia. 3.00
(76) 2.75 (70) 3/4" NPT
4.63 (118) Dia. 3.00
12.65 (321) (76)
Optional mounting flange
3.5"
Optional mounting flange 3.5"
1" NPT
3/4" NPT I.L.
3/4" NPT I.L.
.50 (13) .625 (16)
.50 (13) .625 (16)
Integral Mount with Rigid Probe (24 VDC Two-Wire)
Integral Mount with Rigid Probe and Meter (24 VDC Two-Wire)
4.63 (118) Dia. 3.00
(76) 2 Holes .38 Dia. (10) 4.76 (121) 2.37 (60)
4.54 (115) 3/4" NPT 4.38 (111) Probe 2 diameter .1875 (5) .2500 (6)
6.68 (170) 4.63 (118) Dia. 2.75 (70)
4.63 (118) Dia. 3.00 (76) Optional mounting flange
Optional mounting flange
3.5" 2.00 (51) 3.50 (89) Bracket Front View .50 (13) .625 (16) 3.00 (76) 3.75 (95) 3.00 (76) 3/4" NPT 3/4" NPT I.L.
3/4" NPT Optional anchor assembly P/N 032-8814-001 4.87 (124) 5.50 (141)
2 I.L.
Side View
2.95 (75) .75 (19) Optional weight P/N 032-8814-001 1.25 (32)
Remote Mount with Rigid Probe (24 VDC Two-Wire)
Integral Mount with Flexible Probe (120 VAC or 240 VAC Four-Wire)
4.63 (118) Dia. 3.00 2.75 (70) (76) Optional mounting flange
2 Holes .38 Dia. (10) 4.76 (121) 2.37 (60)
14.08 (358) 4.63 (118) Dia. 3.00 (76)
3.5" 1" NPT 2.00 (51) 3.50 (89) Bracket Front View .50 (13) .625 (16) 3.00 (76) 3.75 (95) Side View 3/4" NPT
10.33 (262)
3/4" NPT I.L.
Remote Mount with Rigid Probe and Meter (24 VDC Two-Wire)
4
AGENCY
AGENCY
APPROVALS
APPROVED MODEL PROTECTION METHOD AREA CLASSIFICATION
FM
082-8303-400 082-8303-410 082-8304-400 082-8304-410
Intrinsically Safe
Class I, Div 1, Groups A, B, C & D; Class II, Div 1, Groups E, F & G; Class III, NEMA 4X Class I, Div 2, Groups A, B, C & D Class II, Div 2, Groups F & G; Class III Class I, Div 1, Groups A, B, C & D; Class II, Div 1, Groups E, F & G; Class III, TYPE 4X Class I, Div 2, Groups A, B, C & D; Class II, Div 2, Groups F & G; Class III Class I, Div 1, Groups C & D; Class II, Div 1, Groups E, F & G Class III, TYPE 4X
Non-Incendive Suitable for: CSA 082-8303-400 082-8303-410 Intrinsically Safe ➀
Suitable for:
082-8303-400 082-8303-410 ATEX 082-84XX-4XX
Explosion Proof ➁
II 1G EEx ia IIC T6
➀ Not I.S. (CSA) for Groups E & F when used with a bare probe. ➁ Approval is valid only with the use of insulated rigid probes.
These units have been tested to EN 50081-2 and EN 50082-2 and are in compliance with the EMC Directive 89/336/EEC.
Loop Resistance vs. Power Supply Voltage 1300 1200 MAXIMUM LOOP RESISTANCE (Ohms) (Including Barrier Resistance) 1100 1000 900 800 700 600 500 400 300 200 100 0 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Power Supply Voltage (Volts) 500 ohms at 24V 1300 ohms @ 40V
Electrical data
5
QUALITY
The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol’s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available.
ESP
Several Model 82 CE transmitter models are available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, match the color coded model number codes in the selection charts (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options.
Expedite Ship Plan
WARRANTY
All Magnetrol electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products.
5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com 145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306 Heikenstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Telex 25944 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317
Copyright © 2004 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Magnetrol and Magnetrol logotype are registered trademarks of Magnetrol International. Performance specifications are effective with date of issue and are subject to change without notice. The brand and product names contained within this document are trademarks or registered trademarks of their respective holders.
BULLETIN: 50-123.18 EFFECTIVE: January 2004 SUPERSEDES : December 2001