344-0442-100

344-0442-100

  • 厂商:

    MAGNETROL

  • 封装:

  • 描述:

    344-0442-100 - Ultrasonic Non-Contact Transmitters for Level, Volume, or Open Channel Flow - Magnetr...

  • 数据手册
  • 价格&库存
344-0442-100 数据手册
Model 344/345 Software version 2.3 Installation and Operating Manual Ultrasonic Non-Contact Transmitters for Level, Volume, or Open Channel Flow Read this Manual Before Installing This manual provides information on the Echotel® Model 344/345 Ultrasonic Transmitter. It is important that all instructions are read carefully and followed in sequence. Detailed instructions are included in the Unit Configuration section of this manual. Conventions Used in this Manual Certain conventions are used in this manual to convey specific types of information. General technical material, support data, and safety information are presented in narrative form. The following styles are used for notes, cautions, and warnings. NOTES WARNING Explosion hazard. Do not connect or disconnect designs rated Explosion-proof or Non-incendive unless power has been switched off and/or the area is known to be non-hazardous Notice of Copyright and Limitations Magnetrol & Magnetrol logotype, and Echotel are registered trademarks of Magnetrol International. Copyright © 2010 Magnetrol International, Incorporated All rights reserved. Performance specifications are effective with date of issue and are subject to change without notice. Magnetrol reserves the right to make changes to the product described in this manual at any time without notice. Magnetrol makes no warranty with respect to the accuracy of the information in this manual. Warranty All Magnetrol electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. Quality Assurance The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol’s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available. Notes contain information that augments or clarifies an operating step. Notes do not normally contain actions. They follow the procedural steps to which they refer. Cautions Cautions alert the technician to special conditions that could injure personnel, damage equipment, or reduce a component’s mechanical integrity. Cautions are also used to alert the technician to unsafe practices or the need for special protective equipment or specific materials. In this manual, a caution box indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. WARNINGS Warnings identify potentially dangerous situations or serious hazards. In this manual, a warning indicates an imminently hazardous situation which, if not avoided, could result in serious injury or death. Safety Messages Follow all standard industry procedures for servicing electrical and computer equipment when working with or around high voltage. Always shut off the power supply before touching any components. Although high voltage is not present in this system, it may be present in other systems. Electrical components are sensitive to electrostatic discharge. To prevent equipment damage, observe safety procedures when working with electrostatic sensitive components. Low Voltage Directive For use in Installations Category II, Pollution Degree 2. If equipment is used in a manner not specified by the manufacturer, protection provided by equipment may be impaired. Echotel Model 344/345 Ultrasonic Non-contact Transmitter Echotel® Model 344/345 Ultrasonic Non-contact Transmitters Table of Contents 1.0 Installation 1.1 Unpacking ................................................................4 1.2 Mounting..................................................................4 1.2.1 Transmitter Location ......................................4 1.2.2 Transducer Location.......................................4 1.3 Transmitter Mounting Procedure ..............................5 1.4 Transducer Mounting Requirements .........................6 1.4.1 Mounting 3⁄4" or 2" NPT Transducer with Factory-Supplied Bracket, Without Transducer Housing .........................7 1.4.2 Mounting 3⁄4" or 2" NPT Transducer with Factory-Supplied Bracket and Transducer Housing .......................................8 1.4.3 Mounting 3⁄4", 1" or 2" NPT Transducer with Flange, With or Without Transducer Housing .......................................9 2.0 Wiring 2.1 Electrostatic Discharge (ESD) Handling Procedure.10 2.2 Transmitter Power Wiring.......................................11 2.3 Transducer Wiring ..................................................11 2.3.1 Without a Transducer Housing.....................12 2.3.2 With a Transducer Housing ..........................13 2.4 Relay Output Wiring ..............................................14 2.5 Output Signal Wiring .............................................14 2.6 RS-232 Output.......................................................15 2.7 Transducer Synchronization ....................................15 3.0 General Information 3.1 Menus .....................................................................16 3.2 Passwords ................................................................16 3.2.1 General Password ..........................................16 3.2.2 Supervisory Password ....................................16 3.3 Operator Keypad.....................................................17 4.0 Unit Configuration 4.1 Complete Menu Structure ......................................18 4.2 Measured Values......................................................19 4.2.1 View Data Log .............................................19 4.3 System Configuration .............................................20 4.3.1 Level Measurement.......................................20 4.3.2 Volume and Level Measurement...................22 4.3.2.1 Custom Table Entry ..............................25 4.3.3 Flow and Level Measurement .......................26 4.3.3.1 Custom Table Entry ..............................28 4.4 I/O Configuration ..................................................29 4.4.1 Relay Settings ...............................................29 4.4.1.1 Relay #1-normal operation....................29 4.4.1.2 Relay #2-normal operation or lead/lag pump control.......................30 4.4.1.3 Relay #3-normal operation or fault detection...................................31 4.4.1.4 Relay #4-normal operation or sampler .............................................32 4.4.2 4–20 mA Settings.........................................33 4.4.3 Totalizer (Flow Mode only) ..........................33 4.5 Advanced Configuration .........................................34 4.6 Diagnostics Menu ...................................................38 4.7 Laptop Menu ..........................................................39 5.0 Reference Information 5.1 Description .............................................................39 5.2 Theory of Operation...............................................39 5.3 Troubleshooting ......................................................40 5.3.1 Troubleshooting System Problems................41 5.3.2 Troubleshooting Flow Chart ........................43 5.4 Agency Approvals....................................................44 5.5 Specifications ..........................................................45 5.5.1 Transmiter ....................................................45 5.5.2 Transducer....................................................45 5.5.3 Physical ........................................................46 5.6 Replacement Parts...................................................48 5.7 Measurement Range Calculations ...........................50 5.8 Model Numbers......................................................52 5.8.1 Transmitter...................................................52 5.8.2 Model 384 38 kHz Transducer.....................52 5.8.3 Model 385 50 kHz Transducer.....................53 5.8.4 Connecting Cable ........................................54 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 1.0 Installation Caution: Read entire section prior to starting installation. 1.1 Unpacking Unpack the instrument carefully. Make sure all components have been removed from the packing material. Inspect all components for damage. Check the contents of the packing slip and report any discrepancies to the factory. Check the nameplate model number to be sure it agrees with the packing slip and purchase order. Check and record the serial number for future reference when ordering parts. Model Number Serial Number 1.2 Mounting 1.2.1 Transmitter Location The transmitter enclosure should be securely fastened to an appropriate supporting structure, in a location that permits easy access for maintenance. Avoid locations that are exposed to direct sunlight, flooding, high levels of radiated electromagnetic interference, and excessive vibration or shock. 1.2.2 Transducer Location Sunshade Model 384/385 transducers must be mounted directly over the material to be measured. Both floor and wall mount transducer brackets are available for use over open tanks or channels. Flange mounts are available for use with closed vessels. If mounted in a location where there is intense, extreme, direct sunlight, a sunshade is recommended. Proper mounting and wiring of the ultrasonic transducer is of the utmost importance. Both the accuracy and the reliability of the Model 344/345 can be adversely affected if the transducer is mounted improperly. NOTE: The 344/345 requires a blocking distance between the transducer and the maximum liquid level. The minimum blocking distance is 12 inches (305 mm) for Model 345 and 18 inches (460 mm) for Model 344. At temperatures above +140° F (+60° C) minimum, it is 18 inches for either model. Maximum blocking distance should be limited to approximately 10 feet (3 m) as this blocking distance is extended at the expense of the useful span over which the instrument operates. Figure 1 Transducer Sunshade 4 Echotel Model 344/345 Ultrasonic Non-contact Transmitter Transducer Air Model 345 25 feet (7.6 m) maximum Range Model 344 35 feet (10.7 m) maximum Blocking Distance* Model 345 24 feet (7.3 m) maximum Span Liquid Model 344 33.5 feet (10.2 m) maximum *Minimum Blocking Distance: 18 inches (460 mm) for the Model 344 12 inches (305 mm) for the Model 345 Figure 2 Transducer Mounting Location–Level/Volume 1.3 Transmitter Mounting Procedure There are two predrilled openings in the enclosure for connecting 3⁄4" NEMA 4X conduit. Refer to Figure 3. 1. Open the door of the unit. 2. Drill holes in the enclosure as required for additional wiring. Be careful not to damage the printed circuit boards. Be sure that the PC boards are not damaged or contaminated when removing filings and/or debris from the housing. 3. Provide watertight seals for all wiring entrances in the enclosure to maintain the NEMA 4X rating. 4. Mount the enclosure to a wall or flat surface using the appropriate screws or bolts. The mounting tabs on the back of the enclosure can be rotated to the sides, or top and bottom to facilitate mounting. Refer to Figure 4. 5. Install conduit for power and control wiring. Be sure all connections to the enclosure maintain a NEMA 4X rating. 6. Close the door until it is time to wire the transmitter. Secure the door by tightening the six screws. Proceed to Transducer Mounting on the next page. Figure 3 Predrilled Conduit Openings NOTE: Do not overtighten the screws that hold the transmitter door closed. Do not use an electric or pneumatic drive on the screw. Overtightening can cause cracking of the housing, resulting in leakage into the housing. Figure 4 Transmitter Mounting Tabs Echotel Model 344/345 Ultrasonic Non-contact Transmitter 5 1.4 Transducer Mounting Requirements 1. Whenever possible, locate the transducer to avoid obstructions between the transducer face and the surface of the level being tracked. The ultrasonic signal is emitted from the transducer with a beam spread of approximately 12 degrees. Objects that extend into the ultrasonic beam can produce echoes that mask the true level. The false target buffering feature allows for blocking out up to nine obstructions inside the tank. Ultrasonic Beam Angle Distance from Transducer Face in feet 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 30' 32' 35' 12° Beam Diameter in feet 0.42' 0.84' 1.25' 1.67' 2.1' 2.5' 2.9' 3.3' 3.76' 4.18' 4.6' 5.02' 5.44' 5.86' 6.28' 6.80' 7.44' Minimum Distance From Wall or Obstruction in inches 2.52" 5.04" 7.5" 10.02" 12.6" 15" 17.4" 19.8" 22.56" 25.08" 27.6" 30.12" 32.64" 35.16" 37.68" 40.8" 44.64" 12° beam Figure 5 Ultrasonic Beam Angle 2. Position the transducer so that the radiating surface or transducer face is exactly parallel to the measurement surface. This will provide the strongest return signals and enhance the reliability of the Model 344/345. NPT Pipe Stub Maximum 11" (280 mm) or less Transducer This end welded or flanged to tank 3. In applications where the material level may come into the blocking distance or where the full tank height will be used, the transducer must be mounted in a short pipe stub (standpipe). The diameter of the standpipe should be at least 8 inches (200 mm) and its length should be limited to 11 inches (280 mm) from transducer face. Refer to Figure 6. NOTE: When mounting in a standpipe, performance is enhanced by using as short of a pipe as possible. 8" (200) Minimum I.D. Figure 6 Transducer Mounting in Standpipe 6 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 4. Avoid installing the transducer in tank top openings that exhaust heated air or vapors. The boundaries between the vapors and the outside air often represent acoustic impedance gradients that can cause troublesome sound reflections. In those installations, the transducer should be mounted well away from the opening inside the tank, or in a pipe stub. Refer to Figures 6 and 7. 5. To prevent electromagnetic noise from disrupting the normal operation of the Model 344/345, it is recommended that each transducer cable be run in its own conduit, separated from other power cables and wiring. 6. Locate the mounting procedure from the chart below and proceed to the appropriate instructions. NPT ⁄4" or 2" 2" 3 ⁄4", 1", or 2" 3 ⁄4" or 2" 3 Figure 7 Transducer Mounting for Tanks With Exhaust Mounting bracket bracket flange flange Housing without with without with Section 1.4.1 1.4.2 1.4.3 1.4.3 Caution: Do not install transducers in the center of domed roof tanks. Locate transducers 1' to 3' off center to minimize false/multiple echoes being reflected off the domed roof. Conduit NPT Threaded Mounting Connection 1.4.1 Mounting 3⁄4" NPT or 2" NPT Transducer with FactorySupplied Bracket, Without Transducer Housing Transducer Wall Mount Bracket Tank Wall 1. Position the bracket such that the transducer mounting hole is positioned over the open tank or channel. Refer to Figure 8. 2. Secure the bracket to the wall, floor, or vessel as appropriate with four 3⁄8" screws. Refer to the mounting hole pattern as shown in the dimensional drawings in Section 5.5.3. 3. Pull transducer cable through mounting bracket and handtighten transducer into fitting in mounting bracket. Caution: HAND-TIGHTEN ONLY. DO NOT use a pipe wrench or other tools when tightening the transducer. Use Teflon® tape on thread for 316 stainless steel transducer. Avoid excessive twisting of the transducer cable. Figure 8 4. Provide conduit from the transducer to the transmitter enclosure. Carefully pull the transducer cable through the conduit toward the transmitter enclosure. This cable will be connected as shown in Section 2.3.1, Transducer Wiring Without Transducer Housing. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 7 Transducer Cable Conduit 5. Tighten the conduit to the threads on the top of the transducer. Refer to Figure 9. NOTE: In high humidity applications, it is recommended that the transducer wiring be completely immersed in an insulating compound where the conduit connects to the transducer (3M™ #4441 Gella™ Reenterable Encapsulant or equivalent). 6. Proceed to Section 2.0, Wiring. Mounting Bracket Transducer 1.4.2 Mounting 2" NPT Transducer with Factory-Supplied Bracket and Transducer Housing Figure 9 1. Position the bracket such that the transducer mounting hole is positioned over the open tank or channel. Refer to Figure 10. 2. Secure the bracket to the wall, floor, or vessel as appropriate with four 3⁄8" screws. Refer to the mounting hole pattern as shown in the dimensional drawings in Section 5.5.3. 3. Mount transducer into the 2" NPT hole in bracket and hand-tighten. Caution: HAND-TIGHTEN ONLY. DO NOT use a pipe wrench or other tools when tightening the transducer. Use Teflon® tape on thread for 316 stainless steel transducer. Avoid excessive twisting of the transducer cable. Conduit Transducer Housing Threaded Mounting Connection Transducer Wall Mount Bracket Tank Wall Figure 10 Transducer Cable Conduit 4. Provide conduit from the transducer to the transmitter enclosure. Carefully pull the transducer cable through the conduit toward the transmitter enclosure. Refer to Figure 11. This cable will be connected as shown in Section 2.3.2, Transducer Wiring With Transducer Housing. NOTE: In high humidity applications, it is recommended that the transducer wiring be completely immersed in an insulating compound where the conduit connects to the transducer (3M™ #4441 Gella™ Reenterable Encapsulant or equivalent). Transducer Housing Mounting Bracket Transducer 5. Tighten the conduit at the 3⁄4"connection on the transducer housing. 6. Proceed to Section 2.0, Wiring. Figure 11 8 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 1.4.3 Mounting 3⁄4", 1", or 2" NPT Transducer with Flange, With or Without Transducer Housing Flange Transducer 1. Position transducer over the tank port. Bolt the transducer flange to the tank port flange. Refer to Figure 12. 2. Hand-tighten transducer into flange. Caution: HAND-TIGHTEN ONLY. DO NOT use a pipe wrench or other tools when tightening the transducer. Use Teflon® tape on thread for 316 stainless steel transducer. Avoid excessive twisting of the transducer cable. Air Liquid Figure 12 3. Install conduit from the 3⁄4" NPT 316 SS nipple on transducer to the transmitter enclosure. For transducers with transducer housing, conduit is connected to the 3⁄4" NPT housing conduit connection. 4. Carefully pull the connecting cable through the conduit to the transmitter. Refer to Figure 13. This cable will be connected as shown in the Transducer Wiring section. Transducer Flange Conduit Transducer Cable Bolts NOTE: In high humidity applications, it is recommended that the transducer wiring be completely immersed in an insulating compound where the conduit connects to the transducer (3M™ #4441 Gella™ Reenterable Encapsulant or equivalent). 5. Proceed to Section 2.0, Wiring. User Flange Transducer Figure 13 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 9 2.0 2.1 Wiring Electrostatic Discharge (ESD) Handling Procedure Magnetrol’s electronic instruments are manufactured to the highest quality standards. These instruments utilize electronic components which may be damaged by static electricity present in most work environments. The following steps are recommended to reduce the risk of component failure due to electrostatic discharge: Ship and store circuit boards in anti-static bags. If an antistatic bag is not available, wrap board in aluminum foil. Do not place boards on foam packing materials. Use a grounding wrist strap when installing and removing circuit boards. A grounded workstation is also recommended. Handle printed circuit boards only by the edges. Do not touch components or connector pins. Make sure that all electrical connections are completely made and none are partial or floating. Ground all equipment to a good, earth ground. • • • • 10 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 2.2 Transmitter Power Wiring Totalizer (+) (–) TB5 L1 L2/N GND TB1 (+) (-) LOOP 4-20 Heater NOTE: Models 344 and 345 have the same motherboard (P/N 030-3564-00X), but have unique daughter boards. The 345 uses a daughter board (P/N 030-3565-001) that drives the 50 kHz Model 385-XXXX-XXX transducer, and the 344 uses a daughter board (P/N 030-3573-001) that drives the 38 kHz Model 384-XXXX-XXX transducer. Caution: DO NOT attempt to operate this unit at voltages other than as specified from the Model Identification as it will damage the unit. Caution: This instrument is grounded through the grounding connector of terminal block TB1. The power input must include a ground wire connected to a good earth ground. Failure to ground the instrument may allow a shock hazard to exist! + Power Supply Loop 4–20 Figure 14 344/345 Motherboard (shown with daughterboard removed) Wiring Colors By Country/Continent U.S. Line 1 (Hot) Line 2 (Neutral) Ground Black White Green/Yellow Europe Blue Black Green/Yellow U.K. Brown Blue Green/Yellow 1. Open the cover of the transmitter enclosure by loosening the six screws. 2. The PC board is marked for 120/240 VAC (L1, L2/N, GND) and 24 VDC (+,–) power connections. Ensure proper connections are made on the six position terminal block TB1. Refer to Figure 14. Spade lugs should be used. For optimum operator safety, observe the wiring colors listed in the chart at left. 3. To prevent electromagnetic noise from disrupting the normal operation of the Model 344/345, the ground (GND) should be connected to a good earth ground with as short a length as possible of heavy wire or copper braid. 4. Proceed to the appropriate transducer wiring section. NOTE: Stainless steel transducers are shipped with a protective rubber cap over the transducer face. Remove this cap after mounting is complete. 2.3 Transducer Wiring Caution: Do not run transducer cable in the same conduit with power, signal, or other transducer cables. The transducer cable consists of two twisted pairs of wire wrapped with a shield. Refer to Figure 15 for wire identification. NOTE: It is imperative that Magnetrol cable part number 037-3176 (Belden Type 8102) be used. If connecting cable was not provided with unit, consult factory for specifications. Maximum total cable length is 500 feet (152 m). AVOID SPLICING CABLE. If a 316 stainless steel transducer is used, connect the green ground wire to an earth ground (i.e. conduit, tank, etc). If a junction box is used, connect earth ground to green terminal screw. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 11 After running the transducer wiring in its own conduit from the transducer to the transmitter, separate the wires into two groups; Group 1 - Ultrasonic signal wiring (orange/white pair) Group 2 - Temperature compensation wiring (blue/white pair) 2.3.1 Transducer Wiring Without Transducer Housing The following instructions are intended for use when the transducer is provided without a transducer housing. There will be 35 feet (10.7 meters) of potted cable coming out of the transducer. This cable can be shortened as desired to accommodate the installation. Group 1 (Ultrasonic Signal) 1. Connect the orange w/white stripe wire to the terminal marked (X1) at TB6. 2. Connect the shield wire to the middle terminal at TB6. 3. Connect the white w/orange stripe wire to the terminal marked (X2) at TB6. Group 2 (Temperature Signal) 1. Connect the white w/blue stripe wire to the terminal labeled positive (+) at TB7. Daughterboard 2. Connect the blue w/white stripe wire to the terminal labeled negative (-) at TB7. NOTE: Both groups of wire (Ultrasonic and Temperature) must be connected. TB6 X2 SH X1 TB7 TB6 –+ TB7 NOTE: Overall cable jacket and individual wire jackets should be cut as short as possible. This illustration is intended for wiring termination clarity only. Figure 15 Wiring without Transducer Housing Ultrasonic Transducer 12 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 2.3.2 Transducer Wiring with a Transducer Housing The following instructions are intended for use when a transducer housing has been provided. This housing is threaded onto the top of the transducer via a 3⁄4" NPT 316 SS nipple. A board inside the housing is used to terminate the transducer cabling. NOTE: If cable was not provided by Magnetrol, Beldon 8102 or equivalent must be used. Group 1 (Ultrasonic Signal) 1. Connect the orange w/white stripe wire from the transducer housing terminal marked (X1) to the terminal inside the transmitter marked (X1) at TB6 on the daughterboard. 2. Connect the shield from the transducer housing terminal marked (SHLD) to the middle terminal at TB6 on the daughterboard. 3. Connect the white w/orange stripe wire from the transducer housing terminal marked X2 (GND) to the terminal marked (X2) at TB6 on the daughterboard. Group 2 (Temperature Signal) 1. Connect the white w/blue stripe wire of the twisted pair from the transducer housing terminal marked (+) to the terminal labeled positive (+) at TB7 on the daughterboard. 2. Connect the blue w/white stripe wire of the twisted pair from the transducer housing terminal marked (-) to the terminal labeled negative (-) at TB7 on the daughterboard. SHLD Daughterboard TRANSDUCER X1 X2 SH +- TEMPERATURE SENSOR Orange with white stripe TB6 SHLD White w/orange stripe TB6 SHLD White with blue stripe Blue with white stripe TB7 TB7 Figure 16 Wiring with Transducer Housing Echotel Model 344/345 Ultrasonic Non-contact Transmitter 13 2.4 T RS232 Relay Output Wiring The 344/345 unit is supplied with 4 relays that can operate as normal independent contact closures or can be used as dedicated relays as follows: Relay 1 Normal Relay 2 Normal or Lead/Lag Pump Alternation (with Relay 1) Relay 3 Normal or Dedicated Fault Relay 4 Normal or Sampler Contact Relay connections are supplied on the motherboard as shown in Figure 17. 1. Two-wire leads are connected to the desired relay terminal block. Connect one wire to the common terminal (labeled CO), and the other to the terminal for the desired contact function—(NC) for normally closed or (NO) for normally open. Repeat this step for each relay. 2. Refer to Relay Settings in the I/O Configuration section for information on configuring the relays. TB2 TB4 TB3 0 NC CO NO RELAY #1 NC CO NO RELAY #2 Figure 17 344/345 Motherboard NC CO NO RELAY #3 NC CO NO RELAY #4 RS485 NOTE: If the device to be operated by the relay has an inductive load, a separate power supply should be used for the electronics. 2.5 Output Signal Wiring The 4–20 mA DC output connections can be made at terminal block TB1, located inside the transmitter housing. Refer to Figure 18. The loop is optically isolated, has nongrounded outputs, and can drive a 1000-ohm load. 1. Connect the positive (+) shielded twisted pair wire from the load to terminal LOOP (+). + (TOTALIZER) HEAT + TOT. TB1 TB5 L1 (+) GND L2/N (-) (+) (-) LOOP 4-20 NC RE 2. Connect the negative (-) shielded twisted pair wire from the load to terminal LOOP (-). NOTE: The shield should be connected to an earth ground at only one location. (HEATER) Figure 18 344/345 Motherboard 14 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 2.6 DB 25F Connector (Laptop) TB2 (344/345 Transmitter) RS-232 Output NOTE: The RS-232 output is only used for downloading information from the optional 31-day data logger. 7 3 2 Figure 19 TX RX RS-232 output connection is located at TB2 and labeled TX and RX. Refer to Figure 19. This connection for the RS-232 is utilized for the hook-up of a laptop computer. In the laptop mode, one can download stored data if unit is equipped with the data logging option. The cable to connect the laptop computer to the Model 344/345 must be supplied by the user. Configure this cable as shown in Figure 19. Downloading instructions are in the Laptop Section on page 39. 2.7 Transducer Synchronization Transducer synchronization is only available with the Model 344 unit. It allows you to run the cabling from multiple Model 384 transducers in the same conduit. This prevents the possibility for crosstalk to occur from one Model 344 to another. The synchronization scheme involves the use of one 344 unit operating as a master, and one or more other units operating as slaves. Multiple Model 344 units should be wired together utilizing TB8 (Figure 20) on the daughterboard as shown in Figure 21 below. The master unit synchronizes the ultrasonic signals such that all units transmit their ultrasonic signals at the same time. This eliminates the possibility of cross talk occurring. No calibration or configuration is necessary other than the wiring shown below. SYNC. IN SYNC. OUT GR. REF. Figure 20 (344 Daughterboard) Synchronization Terminal Block – TB8 SYNC. IN SYNC. IN SYNC. OUT GR. REF. GR. REF. GR. REF. MASTER UNIT SLAVE UNIT SLAVE UNIT Figure 21 Synchronization Wiring Diagram Echotel Model 344/345 Ultrasonic Non-contact Transmitter 15 3.0 3.1 General Information Menus The Model 344/345 transmitter contains a microprocessorbased operator interface which allows for easy configuration of level, volume, or open channel flow applications. All configuration data is entered via a keypad located on the front of the unit. User interface and configuration instructions are broken down into six main groups of menus: MEASURED VALUES SYSTEM CONFIG I/O CONFIG ADVANCED CONFIG DIAGNOSTICS LAPTOP To view measured values Basic programming information required for system operation. Configure input/output functions Additional values that affect the performance and functionality of the transmitter Test functions and system diagnostic information Download data logging to laptop computer (with optional Data Logger only) 3.2 Passwords Caution: The Model 344/345 is shipped from the factory with the password set at 0341. If the password is misplaced or forgotten, consult the factory for assistance. The Model 344/345 has two types of passwords that can be used to protect configuration parameters. They are as follows: 3.2.1 General Password The General Password (PASSWORD) is used for the System Config and the I/O Config portion of the Menu Structure. When a change is made to parameters in these menus (i.e., range, span, 4–20 mA, relays, etc.), the Model 344/345 will prompt the operator to enter a password. This password can be any one- to six-digit numeric combination. 3.2.2 Supervisory Password The Supervisory Password (SUP PSWD) is used for the Advanced Config portion of the Menu Structure. This password is used to protect values that can affect the performance and/or accuracy of the device. NOTE: Although the Supervisory Password is normally used in the Advanced Config menu, this password can also be used in any portion of the menu. The Supervisory Password overrides the General Password. 16 Echotel Model 344/345 Ultrasonic Non-contact Transmitter The Passwords can be changed at any time via the Advanced Config mode. Password Sup Pass If an invalid password is entered, the display will read Password Invalid. By pressing twice, the unit will continue to operate with the previously-programmed parameters. 3.3 Operator Keypad All Unit Configuration instructions in this manual will show the local transmitter display exactly as it will appear to the operator. The operator interface to the 344/345 is via a keypad consisting of the following keys: For numeric entry of parameters. For decimal-point entries. To exit any programming area and return to a measurement mode. For entering new parameter values into memory. Also used to exit the parameter entry mode, if pressed prior to entering numeric parameter values. To sequentially access other parameters. Parameters may also be skipped over without affecting their stored values. The DOWN arrow also acts as a backspace for correcting data entry errors. Helpful when entering a new tag in the Enter Tag section of the Advanced Configuration menu. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 17 4.0 4.1 Unit Configuration Complete Menu Structure Volume (Volume mode only) Flow (Flow mode only) Totalizer (Flow mode only) Level Distance Loop Calculation Temperature View Data Log Previous Menu Level Units Mode Setup Relay Settings 4–20 mA Settings Level Only Volume & Level Flow & Level Vessel Type Volume Units Range Setting Maximum Volume Span Setting Previous Menu Range Setting Span Setting Previous Menu Measured Values System Configuration I/O Configuration Totalizer (Flow mode only) Comm Port Setup Previous Menu Temperature Calibrate Gain Limit Dampening False Targets Set Clock Enter Tag Default Display Calculation Change Password Change Sup Password Previous Menu Test Relays Test 4–20 mA Loop Signal Strength View Version # Extended Errors Previous Menu STRT ____ END ____ Flow Element Flow Units Reference Distance Maximum Flow Maximum Head Low Flow Cutoff Previous Menu Advanced Configuration Diagnostics Laptop QUIT 18 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 4.2 Measured Values The Measured Values Menu contains read-only data that is presently being measured by the Model 344/345 transmitter. Press from the default display to access the Measured Values menu. “Measured Values” along with the Up/Down arrows will be displayed. To view the Measured Values, press at the Measured Values display. “Level” will be displayed if level mode has been selected. “Volume” will be displayed if volume mode has been selected. “Flow” will be displayed if flow mode has been selected. To view the Present Measurement: Press . After reviewing, press to return to Level, Volume (Volume Mode Only) or Flow (Flow Mode Only). To scroll down to the next Measured Value: Press . Pressing the scrolls up the menu. Press at any measured value that you wish to review. If you do not wish to view the measured values at this time, press once if in a main menu mode or twice if in a value read mode from anywhere in the display and the unit will return to the default display, or press at Previous Menu display, and the unit will return to Measured Values. 4.2.1 View Data Log If the 344/345 transmitter was ordered with the Data Logger option, the View Data Log screen allows for storage of up to 31 days of the following measurement data. Level Minimum and maximum level and time of occurrence each day. Volume and Level Minimum and maximum volume and time of occurrence each day. Flow and Level Minimum and maximum flow and time of occurrence each day and total flow for that day. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 19 4.3 System Configuration This menu is used to configure the main control parameters of the Model 344/345. This is also used for first-time configuration of the unit. Once in the System Configuration Menu, you may scroll through the selections by using or arrow. Once the desired selection is displayed, press . The unit is capable of being configured in three different modes of operation. • Level Only • Volume & Level • Flow & Level 4.3.1 Level Measurement NOTE: The 344/345 has a default range setting of 144 inches programmed into the software. If the transducer is installed in the application and the distance from the transducer face is further away than 144 inches, the display will read Loss of Echo. The range setting will have to be adjusted at this point in order to clear the loss of echo error. 1. Press 2. Press 3. Press to display Measured Values. to display System Config. to display Level Units. or to make your units of measure 4. Press then selection. 5. Press to display Mode Setup. NOTE: If your selection is different from the previous selection, the display will ask for a password. At any point PASSWORD? is displayed, key in 0341, and press . 6. Press WARNING to display Level Only. Changing the Mode Setup WILL erase ALL settings if the 344/345 has been previously configured! Confirm change by pressing . Key in your password if Password? is displayed. to display Range Setting. 7. Press NOTE: Range setting is the measured distance from the transducer face to the lowest point of measurement or the zero level point in the vessel. 20 Echotel Model 344/345 Ultrasonic Non-contact Transmitter Transducer Air Model 345 25 feet (7.6 m) maximum Range Model 344 35 feet (10.7 m) maximum Blocking Distance* Model 345 24 feet (7.3 m) maximum Span Liquid Model 344 33.5 feet (10.2 m) maximum *Minimum Blocking Distance: 18 inches (460 mm) for the Model 344 12 inches (305 mm) for the Model 345 Figure 22 8. Press . or toggles between manual set or auto set. NOTE: Manual Set is the preferred mode. Manual Set Mode allows direct entry of the Range value. Enter the distance from the transduer face to the zero level point or bottom of the vessel. Auto Set Mode is only used if the vessel dimensions are unknown. Liquid level must be brought down to zero point in the vessel prior to pressing to automatically set the Range value. 9. Press 10. Press , key in Rng value. to display Span Setting. NOTE: The Span Setting is the distance from the lowest point or zero to the maximum anticipated distance that the level will rise in the tank, without entering the blocking distance of the transducer. Typically, Span is the difference between the Range and the blocking distance. 11. Press to display Manual Set. NOTE: The user can toggle between Manual Set and Auto Set like the range setting scheme. In the auto mode, be certain that the level is at its absolute maximum in the tank otherwise loss of echo may occur. 12. Press , key in Spn value. Caution: If the actual level falls below the maximum range of the unit, the fail-safe selection must be set up so that the desired output is transmitted. When the level falls below the programmed range, the display will show Loss of Echo. If this condition occurs, the fail-safe actions will take place. WARNING: If level exceeds the programmed span, false display or output/control errors will occur. Transducer should be installed and unit programmed to assure that this level cannot occur. 13. Press 14. Press 15. Press to display Previous Menu to display System Config. once to display I/O Config. System Configuration is now complete. Proceed to I/O Configuration, Section 4.4. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 21 4.3.2 Volume and Level Measurement This menu is used to configure the parameters of the Model 344/345 for Volume and Level Measurement. Once in the System Config menu, you may scroll through the selections by using or . Once the desired selection is displayed, press . The unit is capable of being configured in three different modes of operation. • Level Only • Volume & Level • Flow & Level 1. Press 2. Press 3. Press to display Measured Values. to display System Config. to display Level Units. or to make your units of measure 4. Press then selection. 5. Press to display Mode Setup. NOTE: If your selection is different from the previous selection, the display will ask for a password. At any point if PASSWORD? is displayed, key in 0341, and press the key. 6. Press WARNING then or until Volume & Level is displayed. Changing the Mode Setup WILL erase ALL settings if the 344/345 has been previously configured! Confirm change by pressing . Key in your password if Password? is displayed. to display Vessel Type. or to scroll through vessel type 7. Press 8. Press then selections. Horiz/Flat Horiz/Elipp. Horiz/Sphere Verti/Flat Verti/Conical Spherical Custom Table (refer to Section 4.3.2.1) 22 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 9. Press Horizontal/Flat Rad to select your vessel type. then key in prompted values. Radius End Radius (enter value of one end of vessel) Length Height Cone 10. Press Rad__. Length side view End__. Len__. Ht__. Con__. 11. Press Horizontal/Elliptical Rad to display Password?. Key in password. 12. Press . The display reads Processing.... and then Volume Units. Length End side view Horizontal/Spherical Rad side view Length 13. Press then or to scroll through volume units selections. Cubic Feet Gallons Million Gallons Cubic Meters Liters Million Liters Petroleum Barrel 14. Press 15. Press to select units. to display Range Setting. Vertical/Flat Rad top view Height NOTE: Range setting is the measured distance from the transducer face to the lowest point of measurement or zero. 16. Press then auto set. Vertical/Conical Rad Height or to toggle between manual set or top view Cone NOTE: Manual Set is the preferred mode. Manual Set Mode allows direct entry of the Range value. Enter the distance from the transduer face to the zero level point or bottom of the vessel. Auto Set Mode is only used if the vessel dimensions are unknown. Liquid level must be brought down to zero point in the vessel prior to pressing to automatically set the Range value. 17. Press Spherical , key in Rng value. to display Maximum Volume. key in Max value. to display Span Setting 18. Press 19. Press Rad 20. Press Figure 23 Vessel Types NOTE: The Span Setting is the distance from the lowest point or zero to the maximum anticipated distance that the level will rise in the tank, without entering the blocking distance of the transducer. Typically, Span is the difference between the Range and the blocking distance. 23 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 21. Press to display Manual Set. NOTE: The user can toggle between Manual Set and Auto Set. In the Auto Set mode, be certain that the level is at its absolute maximum in the tank otherwise loss of echo may occur. 22. Press , key in Spn value. Caution: If the actual level falls below the maximum range of the unit, the fail-safe selection must be set up so that the desired output is transmitted. When the level falls below the programmed range, the display will show Loss of Echo. If this condition occurs, the fail-safe actions will take place. WARNING: If level exceeds the programmed span, false display or output/control errors will occur. Transducer should be installed and unit programmed to assure that this level cannot occur. 23. Press 24. Press 25. Press to display Previous Menu to display System Config. once to display I/O Config. System Configuration is now complete. Proceed to I/O Configuration, Section 4.4. 24 Echotel Model 344/345 Ultrasonic Non-contact Transmitter Points 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Level % 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 % of Volume 0.00 3.60 5.58 7.55 9.51 11.48 13.44 15.41 17.37 19.34 21.31 23.28 25.25 27.21 29.18 31.15 33.11 35.08 37.05 39.02 40.98 42.95 44.92 46.89 48.85 50.82 52.79 54.75 56.72 58.69 60.66 62.62 64.58 66.56 68.51 70.49 72.44 74.42 76.39 78.36 80.33 82.30 84.26 86.23 88.20 90.16 92.13 94.10 96.06 98.03 100.00 4.3.2.1 Custom Table Entry 1. If Custom Table is selected at step 8, Press Table Name. to display 2. Press to designate a Table Name. Press to start the first character scrolling. If a faster scrolling speed is desired, press again. Press to stop at a character. Use or to single-step to a desired character. 3. Press once again to proceed to the next character. For the balance of the Table Name, perform the same steps as stated above. A maximum of 13 characters can be used. 4. When completed, press 5. Press to display Max Table Span. and key in Max value in the chosen level units. 6. Press to display Max Table Value. Key in the maximum value in the chosen volume units. (For example: if the value for 100% of volume in the table was 5,500 gallons, enter 5500.) 7. Press to display Table Units. These are the table volume units. Press to start the first character scrolling. If a faster scrolling speed is desired, press again. Press to stop at a character. Use or to single step to a desired character. 8. Press once again to proceed to the next character. For the balance of the table units, perform the same steps as stated above. A maximum of 3 characters can be used. 9. When completed, press 10. Press to display 00%; 0. to display Enter Table Pts. 11. Enter percent of volume for each percent of level displayed in 2% steps. Table is complete after all 51 points are entered. See Figure 24 at left for an example. 12. Press to display Previous Menu. 13. Press to display Volume Units. Press and Operation Denied will display because volume units have already been entered. 14. Press or to display Range Setting. 15. Proceed with step 16, Section 4.3.2 on page 23. Figure 24 Custom Table Example Echotel Model 344/345 Ultrasonic Non-contact Transmitter 25 Flow Element Menu 4.3.3 Flow and Level Measurement Vnotch 22.5° 30° Vnotch Vnotch 45° Vnotch 60° Vnotch 90° Vnotch 120° Parshall 1" Parshall 2" Parshall 3" Parshall 6" Parshall 9" Parshall 12" Parshall 18" Parshall 24" Parshall 36" Parshall 48" Parshall 60" Parshall 72" Parshall 96" Parshall 120" Parshall 144" Rct/Cntr (Rectangular w/End Contractions) Rectangular (Without End Contractions) Cipolletti Palmer-B 4" (Palmer-Bowlus) Palmer-B 6" Palmer-B 8" Palmer-B 10" Palmer-B 12" Palmer-B 15" Palmer-B 18" Palmer-B 21" Palmer-B 24" Palmer-B 27" Palmer-B 30" H-Flume 6" H-Flume 9" H-Flume 12" H-Flume 18" H-Flume 24" H-Flume 30" H-Flume 36" H-Flume 54" I 12 Z (I-Flume) I 30 Z I 40 Z I 50 Z I 60 Z I 80 Z I 10 H I 13 H I 16 H Custom Table 26 This menu is used to configure the main control parameters of the Model 344/345 for the Flow and Level Measurement. Once in the System Config menu, you may scroll through the selections by using or . Once the desired selection is displayed, press . The unit is capable of being configured in three different modes of operation. • Level Only • Volume & Level • Flow & Level 1. Press 2. Press 3. Press to display Measured Values. to display System Config. to display Level Units. or to make your units of measure 4. Press then selection. 5. Press to display Mode Setup. NOTE: If your selection is different from the previous selection, the display will ask for a password. If at any point PASSWORD? is displayed, key in 0341 and press the key. 6. Press WARNING then or until Flow & Level is displayed. Changing the Mode Setup WILL erase ALL settings if the 344/345 has been previously configured! Confirm change by pressing . Key in your password if Password? is displayed. to display Flow Element. to scroll through flow element selec- 7. Press 8. Press then or tions shown at left. 9. Press 10. Press to select your flow element. to display Password?. Key in password. 11. Press . The display reads Processing.... and then Flow Units. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 12. Press then or to scroll through flow units selections. Cubic Feet/Sec Cubic Feet/Min Cubic Feet/Hr Gallons Per Min Gallons Per Hour Million Gals/Day Cubic Meters/Sec Cubic Meters/Min Cubic Meters/Hr Liters/Min Liters/Hour MegaLiters/Day to select units. to display Reference Dist. 13. Press 14. Press NOTE: Reference distance is the measured distance from the transducer face to the lowest point of measurement or zero flow. 15. Press then Auto set. or to toggle between Manual or NOTE: Manual Set is the preferred mode. Manual Set Mode allows direct entry of the Reference Distance. Enter the distance from the transduer face to the point of zero flow in the flume or weir. Auto Set Mode is only used if the flume or weir dimensions are unknown. Liquid Head must be brought down exactly to the zero flow point prior to pressing to automatically set the Reference Distance value. 16. Press 17. Press 18. Press 19. Press , key in Reference Distance value. to display Maximum Flow. key in Max value. to display Maximum Head or to toggle between Manual or 20. Press then Auto set. 21. Press 22. Press 23. Press 24. Press 24. Press 25. Press key in Head value. to display Low Flow Cutoff. , key in Cut value. to display Previous Menu. to display System Config. once to display I/O Config. System Configuration is now complete. Proceed to I/O Configuration, Section 4.4. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 27 Points 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Head % 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 94 96 98 100 % of Flow 0.00 3.60 5.58 7.55 9.51 11.48 13.44 15.41 17.37 19.34 21.31 23.28 25.25 27.21 29.18 31.15 33.11 35.08 37.05 39.02 40.98 42.95 44.92 46.89 48.85 50.82 52.79 54.75 56.72 58.69 60.66 62.62 64.58 66.56 68.51 70.49 72.44 74.42 76.39 78.36 80.33 82.30 84.26 86.23 88.20 90.16 92.13 94.10 96.06 98.03 100.00 4.3.3.1 Custom Table Entry 1. If Custom Table is selected at step 8, Press Table Name. to display 2. Press to designate a Table Name. Press to start the first character scrolling. If a faster scrolling speed is desired, press again. Press to stop at a character. Use or to single step to a desired character. 3. Press once again to proceed to the next character. For the balance of the Table Name, perform the same steps as stated above. A maximum of 13 characters can be used. 4. When completed, press 5. Press to display Max Table Span. and key in Max value in the chosen level units. 6. Press to display Max Table Value. Key in the maximum value in the chosen flow units. (For example: if the value for 100% of flow in the table was 5,500 GPM, enter 5500.) 7. Press to display Table Units. These are the table flow units. Press to start the first character scrolling. If a faster scrolling speed is desired, press again. Press to stop at a character. Use or to single step to a desired character. 8. Press once again to proceed to the next character. For the balance of the table units, perform the same steps as stated above. A maximum of 3 characters can be used. 9. Press to display Timebase. Use or to choose Seconds, Minutes, Hours, or Days. This selection enables the totalizer to function properly. 10. When completed, press 11. Press to display 00%; 0. to display Enter Table Pts. 12. Enter percent of flow for each percent of head displayed in 2% steps. Table is complete after all 51 points are entered. See Figure 25 at left for an example. 13. Press to display Previous Menu. 14. Press to display Flow Units. Press and Operation Denied will display because flow units have already been entered. 15. Press or to display Reference Distance. 16. Proceed with step 14, Section 4.3.3 on page 27. Figure 25 Custom Table Example 28 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 4.4 I/O Configuration This menu is used to configure relay settings, output, totalization, and communications parameters of the Model 344/345. Once in the I/O Configuration menu, scroll through the selections by using or arrow. Once the desired selection is displayed, press . 4.4.1 Relay Settings All relays can be configured for normal mode of action (i.e., pump control, high or low alarm) or for dedicated relays as follows: Relay 1- Normal Relay 2- Normal or Lead/Lag Pump Alternation (with Relay 1) Relay 3- Normal or Dedicated Fault Relay 4- Normal or Sampler Contact 4.4.1.1 Relay #1 – normal operation 1. Press 2. Press 3. Press 4. Press 5. Press to display Measured Values. to display System Config. to display I/O Config. to display Relay Settings. to display Relay #. . The operating status of the relay will to return to 6. Key in , press be displayed. NOTE: If relay number is entered in error, press Relay Settings. 7. Press or to toggle between Disabled and Enabled. With Enabled displayed, press to display Setpoint. NOTE: If in Flow or Volume mode, the unit will prompt to set relays in Level or either Flow or Volume mode. 8. Press 9. Press , key in On value. , key in Off value. NOTE: If keyed in On and Off values are identical, On >= Setpoint will be displayed. Press or to toggle between < and >=. 10. Press 11. Press , key in On Delay value. , key in Off Delay value. NOTE: Delay is the number of seconds before activating or deactivating the relay contact closure. This value is adjustable from 1 to 120 seconds. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 29 12. Press to display Failsafe. Press between On, Off, or Hold. or to toggle NOTE: With loss of power, all relays, regardless of fail-safe setting, will de-energize. NOTE: Fail-safe is the state the relay will assume if a fault is detected or echo loss occurs. Off means the relay is de-energized. On means the relay is energized and Hold means the relay is left in the state the relay was in when the fault occurred. 13. Press to display Relay Settings. to proceed to Section 4.4.2, NOTE: If all relays are set, press 4–20 mA Settings. 4.4.1.2 Relay #2 – normal operation or lead/lag pump control NOTE: Lead/lag pump control provides for an exchange of the role or function of two pumps in order to provide for even pump wear. The relay action is identical to the Auto Empty Mode or the Auto Fill Mode; however, following each pump shutdown, the lead/lag role of each pump is exchanged. Air Relay 2, Energized Relay 1, Energized Liquid Relays 1 & 2, De-energized 1. Press 2. Key in to display Relay #. , press to display Mode: Normal. to return to Figure 26 NOTE: If relay number is entered in error, press Relay Settings. 3. Press press or to toggle between Normal and LeadLag1/2, . The operating status of the relay will be displayed. NOTE: If lead/lag is selected, relays 1 and 2 will alternate. When using lead/lag pump control, set points cannot be identical; they must operate in the same direction. Refer to Figure 26. Pump II On Pump I On Pump II Off Pump I Off Pump I On Pump II On Pump I Off Pump II Off Pump II On Pump I On Pump II Off Pump I Off 4. Proceed to Step 7 in Section 4.4.1.1 Relay #1. Cycle I Cycle II Cycle III Figure 27 30 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 4.4.1.3 Relay #3 – normal operation or fault detection 1. Press 2. Key in to display Relay #. , press to display Mode: Fault. to return to NOTE: If relay number is entered in error, press Relay Settings. 3. Press or to toggle between Fault and Normal. and proceed to Step 7 in Section 4.4.1.1 to display T'ducer. 4. If Normal, press Relay #1. 5. If Fault, press NOTE: Each of the following menu items may be selected to operate with Relay 3. Using or , toggle between Enabled and Disabled. Press to continue to next item. T’ducer The unit was not able to detect a transducer connected or was not able to determine the transducer’s frequency. The unit is not able to detect a return signal from the transducer. The transducer is ringing long enough to ring beyond the blocking distance and into the span. The calculated value for the loop output is less than 4 mA or greater than 20 mA. The loop output will be in its fail-safe mode. The signal from the temperature sensor in the transducer is out of range. Either a short or open lead is detected. This error is generated when there is an error writing configured values to non-volatile memory. No Echo Ringdown Loop flt Temp. System Fault Action Energized De-Energized 6. With Fault Action displayed, press . Using toggle between Energize or De-Energize. 7. Press to display Previous Menu, press Relay Settings. NOTE: If all relays are set, press 4–20 mA Settings. or , to display to proceed to Section 4.4.2, Echotel Model 344/345 Ultrasonic Non-contact Transmitter 31 4.4.1.4 Relay #4 – normal operation or sampler 1. Press 2. Key in to display Relay #. , press to display Mode: Normal. to return to NOTE: If relay number is entered in error, press Relay Settings. 3. Press or to toggle between Normal and Sampler. and proceed to Step 7 in Section 4.4.1.1 . 4. If Normal, press Relay #1. 5. If Sampler, press NOTE: The pulse duration is 90 milliseconds for the contact closure. 6. Press or to toggle between Sample By Time or Sample By Flow, press . If Sample By Flow is chosen, proceed to step 10. NOTE: Sample By Time is only allowed with units ordered with data logging option. 7. Interval 0000 is displayed. Key in contact closure time in minutes, press . 8. Press to display Password?. Key in password. 9. Press . The display reads Processing.... and then Relay Settings. NOTE: If all relays are set, press 4–20 mA Settings. to proceed to Section 4.4.2, 10. FLW ___. is displayed. Key in contact closure rate, press . NOTE: Sample By Flow is a momentary (90 millisecond) contact closure. Example: If 1000 gallons is entered, relay 4 will energize once for every 1000 gallons. 11. Press to display Relay Settings. to proceed with 4–20 mA Settings. NOTE: If all relays are set, press 32 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 4.4.2 4–20 mA Settings NOTE: 4–20 mA settings is dependent on the choice of Mode Setup designated in Section 4.3, System Configuration. 1. Press to display 4: __., Setpoint Level, Setpoint Flow or Setpoint Volume, depending on the mode that the unit is in. 2. Press 3. Press 4. Press or to toggle between Level, Flow and Volume. to display 4: __. Key in value. to display 20: __. Key in value. to toggle 5. Press to display Failsafe. Press or between 4ma, 20mA, 22mA and Hold. 6. Press to display Password?. Key in password. 7. Press . The display reads Processing.... and then 4–20 Relay Settings. NOTE: If all 4–20 mA Settings are complete, press Section 4.4.3, Totalizer (Flow Mode only). to proceed with 4.4.3 Totalizer (Flow Mode only) NOTE: The selected display units will determine the totalizer units. Example: if units are gallons and multiplier is 100, for every 100 gallons the totalizer will advance once. This is the weight of each count of flow increment shown on the multiplier totalizer. 1. Press then Software. 2. Press 3. Press 4. Press or to toggle between Hardware and . Key in multiplier value. to display Password?. Key in password. to display Totalizer. NOTE: Repeat this procedure for the remaining option (hardware or software). NOTE: The hardware/software totalizing multiplier should be chosen so that at maximum value, the advance rate should not exceed once per minute. Minimum multiplier is 0.01. NOTE: If power to the unit is removed, Software Totalizer will reset to zero, unless data logger option was ordered. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 33 4.5 Advanced Configuration This menu is used to calibrate non-control parameters of the Model 344/345. Each menu item will prompt for Sup Pswd? as a protection against unauthorized changes. WARNING: These values are factory set and should not be changed without consulting the factory. 1. Press 2. Press 3. Press 4. Press to display Measured Values. to display System Config. to display I/O Config. to display Advanced Config. 5. Press then or to scroll through Advanced Configuration selections. Temperature Calibrate Gain Limit Dampening False Targets Set Clock Enter Tag Default Display Calculation Change Password Change Sup Password Previous Menu Temperature 1. Press to display the temperature sensed inside the transducer in degrees °F (°C if metric level units are chosen). 2. If the transducer is changed or the value seems to be in error, enter the correct value and press . 3. Display will read Sup Password?, your chosen password must be entered at this time. Press . Calibrate 1. Press to display the measured distance in the present units of level. 2. If the process is other than air and/or a known distance is available, enter the correct value and press . NOTE: This feature allows the instrument to be used with inert gas blankets where the speed of sound differs significantly from atmospheric pressure. 34 Echotel Model 344/345 Ultrasonic Non-contact Transmitter NOTE: If calibrate mode is not properly used, this may cause false level readings. Consult factory for reset procedures. 3. Display will read Sup Password?; your chosen password must be entered at this time. Press . Gain Limit 1. Press to display the value of Maximum gain that the unit will use. This value is from 1–32 and the unit steps up in single gain increments until a suitable signal is received. Limiting the Max Gain to a lower value may help limit noise problems. 2. Enter any value between 1 and 32. Press . 3. Display will read Sup Password?, your chosen password must be entered at this time. Press . NOTE: The Model 344/345 adapts its gain to suit the conditions of the application. There are 32 gain steps. The higher the number, the higher gain/drive required to detect an acceptable signal. Dampening 1. Press to display the value dampening. This factor is a smoothing or averaging factor for the Model 344/345 output. The higher the number, the more smoothing to improve performance during rapid changes. The value may be between 1 and 16. 2. Enter any value between 1 and 16. Press . 3. Display will read Sup Password?; your chosen password must be entered at this time. Press . NOTE: The dampening factor is a smoothing or averaging term. The 344/345 averages echo values over a number of previous measurement cycles. The dampening factor instructs the number of cycles over which the unit should perform this average. Thus, the higher the dampening factor, the more averaging and the slower it reacts to a step change in level. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 35 False Targets NOTE: Contact the factory prior to using the False Targets feature. The false target rejection feature allows for semi-automatic programming as follows. The tank must be empty or the level below any false targets that will be rejected. The 344/345 will proceed to find the first target which provides a detectable echo. The display will prompt the user to identify each echo as either a false target or the true distance to the process material. 1. If the echo results from a false target, press . The 344/345 will store gain and distance parameters about each target that will allow it to discern true levels from false target echoes. The 344/345 will suppress this target and increase gain until the next target is obtained. This procedure can be repeated until all false targets have been acknowledged. 2. After the true distance is displayed, press 3. The 344/345 will prompt “Press targets. 4. Press to continue. . ” to save all new false 5. Display will read Sup Password?, your chosen password must be entered at this time. Press . NOTE: Entering this menu again will restart the false target selection and clear the old targets. WARNING: Make sure that all false targets are cleared or deleted from the software. Press when Tar 0:___in is displayed. Press and input Supervisory Password code. Set Clock This allows for setting or changing of the date and time. This is only available with the Data Logging option. Unit prompts for: Month? Date? Year? Hour? (24-hour format) Minute? After entering these values, the unit prompts then requests password. to set and 36 Echotel Model 344/345 Ultrasonic Non-contact Transmitter Enter Tag This menu shows the present Tag - Magnetrol. 1. If desired, this tag can be changed by using scan through characters. or to 2. Press to use the character at that location in the Tag. Pressing the key will start scrolling of the available characters. When close to the desired character, press and use arrows to reach desired character. Default Display This menu allows the operator to select the items to be displayed during normal operation.The following items may be toggled Enabled/Disabled using or : Level Vol/Flow (Only when Volume or Flow mode is chosen) Loop Tag Clock Calculation Totalizer The last menu item is Previous Menu. If any change was made in the default display, pressing at this point will cause the unit to prompt for the Sup Pswd. Calculation 1. Press 2. Press to display Existing Text Is. again to display Text:. or and press at each entry. 3. Enter Text by using Display will then read Mult:. This is the multiplier used to show up in calculation. This value is multiplied by your level, flow or volume reading. NOTE: The calculation is intended for display purposes only. It does not affect the control relays or loop current output. Change Password Allows for a change of password. Requires the Sup Pswd. Change Sup Password Allows for a change of Sup Pswd. Requires the Sup Pswd. Previous Menu 1. Press 2. Press to return to the previous menu, Advanced Config. arrow to proceed to Diagnostics. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 37 4.6 Diagnostics Menu This menu is used to provide the user with testing the functionality and providing useful information for troubleshooting of the unit. 1. Press 2. Press 3. Press 4. Press 5. Press to display Measured Values. to display System Config. to display I/O Config. to display Advanced Config. to display Diagnostics. 6. Press then or to scroll through Diagnostic selections. Test Relays Test 4–20 Loop Signal Strength View Version# Extended Errors Previous Menu Test Relays This menu allows the operator to cycle individual control relays on or off. Test 4–20 mA Loop By entering different values into the system, the actual loop current output can be adjusted to test dependent devices and/or control loops. The entered mA value will remain until the key is pressed. Signal Strength This menu provides the user with a gain value from 1 to 32 (1=low gain/sensitivity, 32=high gain/sensitivity) and a percent received signal strength from 0 to 100%. The 344/345 processor controls the signal strength at 60–70%. This is a variable gain circuit which self-adjusts for an optimum signal return. View Version This is the software version number in the 344/345. Extended Errors This information may be requested during troubleshooting of the unit. 38 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 4.7 Laptop Menu This menu is used to enter the start and end day range for downloading of stored data log for the Model 344/345 with optional data logging feature. 1. Press 2. Press 3. Press 4. Press 5. Press 6. Press to display Measured Values. to display System Config. to display I/O Config. to display Advanced Config. to display Diagnostics. to display Laptop. 7. Press to display Strt. Enter the number of the day (the most recent day) to begin downloading. The present day is always day 1. Data up to 31 days prior to the current day can be downloaded. 8. Press and End will appear. Key in the ending day. 9. Press , Processing… will be displayed. If the laptop is connected for RS-232 and the baud rate is compatible as set in the I/O Config, the unit will begin to download the start/end day range. See Figure 28 at left. DB 25F Connector (Laptop) TB2 (344/345 Transmitter) 7 3 2 Figure 28 TX RX NOTE: This is an updating 31-day format. It will download the minimum, maximum (at times of occurrence), and total flow data for selected days. When the transmission of data is complete, the display will return to Laptop. Any PC communication program may be used to capture this data. Start the communications program. Set up as 8 bit, 9600 Baud, 1 stop bit. Select download file (usually page DOWN key), select ASCII file type. Refer to your communications program documentation if needed. 5.0 5.1 Reference Information Description Model 344/345 transmitters perform level, volume, or open channel flow measurements of liquids and slurries. 5.2 Theory of Operation Pulses generated by the electronics are transmitted to the ultrasonic transducer. The transducer directs an ultrasonic pulse to the liquid surface. The returning echo/signal is detected by the transducer. The electronics convert the signal into a digital representation of the level, flow or volume measurement. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 39 5.3 Troubleshooting Following these five steps will assist in troubleshooting application difficulties with Model 344/345: Step 1: Step 2: Step 3: Application Checklist – review fundamental application parameters Installation Checklist – review typical installation problems Troubleshooting Table – explains diagnostic error conditions shown on the LCD display and some typical electronic problems. Step 4: Step 5: Troubleshooting Flowchart – step-by-step procedure Contact factory. APPLICATION CHECKLIST Check for the following application sensitivities before proceeding to the next section: VAPORS INVISIBLE (may alter speed of sound) VISIBLE (may cause false reflections or attenuation) FOAM SURFACE AGITATION ANGLE OF REPOSE TEMPERATURE PRESSURE OBSTRUCTIONS If any of the above sensitivities are present, consult the factory for recommendations. INSTALLATION CHECKLIST CABLE 1. _____ 2. _____ 3. _____ Was Belden 8102 used? If not, improper operation may occur. Is transducer wiring run in a dedicated conduit? 4. _____ Is shield connected at both ends? Is there an angle of repose? (Solids) NOTE: Refer to Section 5.7, Measurement Range Calculations, if any of the points in the PROCESS section have been checked. 3. _____ PROCESS cont. Does the tank have a mixing blade? Could it be providing false level readings or creating a vortex resulting in echo loss. TRANSDUCER 1. _____ 2. _____ Check transducer alignment (vertical) Is transducer mounted hand tight? Over tightening may cause ringing, some installations may require use of a “shock” absorber. Minimum nozzle diameter 8 inches. Maximum nozzle height 11 inches. Check beam path for obstructions, including tank wall. Refer to Section 1.4 for Sonic Beam Dispersion chart. Check transducer housing for moisture. What is the distance from the transducer face to current level? TRANSMITTER Enter the specified menu and obtain the following information before consulting the factory. MEASURED VALUES MENU LEVEL____________________ DISTANCE ________________ SYSTEM CONFIGURATION RANGE___________________ SPAN ____________________ ADVANCED CONFIGURATION TEMPERATURE ___________ DIAGNOSTICS MENU GAIN _____________________ 3. _____ 4. _____ 5. _____ 6. _____ 7. _____ PROCESS 1. What is the temperature? a. At transmitter __________________ b. At transducer __________________ 2. What is the media being measured? ________________ 1. Transmitter is I indoors I outdoors? SIGNAL STRENGTH _______% 2. What is the transmitter serial number? ___________________________________________________ 40 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 5.3.1 Troubleshooting System Problems Display COMM PARAM FAIL Problem The configuration parameters for the communications port are corrupt. Solution Press ENT to continue. This loads default values for the communication parameters. The configuration parameters should be checked to make sure that they match your application. Press ENT to continue. This will load default values for the main parameters. All of the items in the System Config menu need to be verified. Press ENT to continue; the table is cleared. If a custom table is not being used, then this error can be ignored. If you are using a custom table, the table has to be re-entered. Press ENT to continue. The relay is disabled and the settings are set to default values. Reconfigure the relay from the I/O Config menu. Press ENT to continue. The relay is disabled and the settings are set to default values. Reconfigure the relay from the I/O Config menu. Press ENT to continue. The relay is disabled and the settings are set to default values. Reconfigure the relay from the I/O Config menu. Press ENT to continue. The relay is disabled and the settings are set to default values. Reconfigure the relay from the I/O Config menu. Press ENT to continue. The loop is disabled and the settings are set to default values. Reconfigure the relay from the I/O Config menu. Press ENT to continue. New values need to be entered for the calculation. This is done from the Calibration menu. Press ENT to continue. Enter new passwords from the Calibration menu. Press ENT to continue. The data log is cleared. MAIN PARAM FAIL The main parameters which store range/reference and span/headroom are corrupt. There is an error in the custom strapping table entry. STRAP TABLE FAIL RLY1 PARAM FAIL The parameters for Relay 1 are corrupt. The parameters for Relay 2 are corrupt. The parameters for Relay 3 are corrupt. The parameters for Relay 4 are corrupt. The 4–20 mA loop parameters are corrupt. The calculation parameters are corrupt. The passwords are corrupt. RLY2 PARAM FAIL RLY3 PARAM FAIL RLY4 PARAM FAIL LOOP PARAM FAIL CALC PARAM FAIL PASSWORD LOST DATA LOG LOST P.O.S.T. FAILED The data log is corrupt. Power on self test failed. Turn unit off and apply power again. If the error clears, it was Microprocessor internal register able to set the register to the proper value and will function properly. was not set correctly on power up. The software will attempt to set the register to the proper value The unit was not able to detect a transducer connected or was not able to determine the transducer's frequency. The unit is not able to detect a return signal from the transducer. Ensure that the transducer is connected properly to the unit. If the transducer wiring is properly connected, contact factory for replacement transducer. TRANSDUCER FAIL LOSS OF ECHO Ensure that the level to be detected is within the range and span of the unit. Check the application for foam, obstructions, or heavy vapors. Echotel Model 344/345 Ultrasonic Non-contact Transmitter 41 5.3.1 Troubleshooting System Problems Display RINGDOWN ERROR Problem The transducer is ringing long enough to ring into the span of the unit. Solution Decrease the span to increase the blocking distance (range minus span) of the unit. Replace the transducer (the current transducer may have a problem that causes it to ring too long. TEMPERATURE FAULT The signal from the temperature Check to see that the sensor wires are connected properly. sensor in the transducer is out of Ensure that the sensor wires are not shorted or open. range. Either a short or open lead detected. The current operation is not allowed because the proper password was not entered. The value that was entered was not in an acceptable range. The value for the 4 mA point and the 20 mA point cannot be equal. Setting relay 1 and 2 for lead/lag is not allowed. The password entered is not valid. The real time clock was not found on the board. No data logging or time sampling is allowed. The calculated value for the loop output is greater than 20 mA. The loop output will be in its fail-safe mode. The calculated value for the loop output is less than 4 mA. The loop output will be in its fail-safe mode. Display is too dim or too light Retry the proper password. OPERATION DENIED “OUT OF RANGE” Re-enter a value within the proper limits. CANNOT BE EQUAL Choose the values that are not the same and re-enter. INVALID LEAD/LAG Check that both relays are enabled and that the set points are proper for lead/lag operation. Retry the previous operation and enter the proper password. PASSWORD INVALID NO CLOCK PRESENT If you need the real time functions, contact the factory to see if your unit was ordered with the data logging option. LOOP > 20 mA If the level is within a normal operating range, adjust the loop parameters to allow proper tracking of the level. If the level is out of the normal 4–20 mA range then correct the problem with the level. If the level is within a normal operating range, adjust the loop parameters to allow proper tracking of the level. If the level is out of the normal 4–20 mA range then correct the problem with the level. Turn the CONTRAST adjustment potentiometer clockwise to darken the display or counterclockwise to lighten the display, until the desired contrast is obtained. The CONTRAST pot is located on the top left of the motherboard above the ribbon cable connection. If a new PC board was recently purchased, it may be incompatible with the other boards. In this case, the JP9 jumper on the motherboard (underneath daughterboard) should be moved to the other position. LOOP < 4 mA Faint display 1/2 display lit Only half of display is lit 42 Echotel Model 344/345 Ultrasonic Non-contact Transmitter 5.3.2 Troubleshooting Flow Chart IS LED D10 LIT ON MOTHER BOARD? • CHECK POWER SUPPLY NO • CHECK FUSE YES • CHECK RIBBON CABLE IS LCD DISPLAY ON? NO • ADJUST CONTRAST POT (SEE SECTION 5.3.1) • CHECK BOARD CONNECTION YES ACCESS DENIED TO PROGRAMMING • VERIFY PASSWORD YES NO IS DISPLAY SHOWING LOSS OF ECHO RINGDOWN ERROR TEMP. FAULT TRANSDUCER FAIL? • CHECK TRANSDUCER WIRING • CHECK RANGE AND SPAN SETTINGS YES • MAKE SURE TARGET IS NOT BEYOND RANGE OR ABOVE SPAN • IF S.S. SENSOR, MAKE SURE PLASTIC PROTECTIVE COVER HAS BEEN REMOVED NO IS LEVEL READING CORRECT? • CHECK RANGE AND SPAN SETTINGS NO • CHECK TEMPERATURE READING YES ARE RELAYS OPERATING PROPERLY? • CHECK RELAY PROGRAMMING NO • MAKE SURE UNIT IS READING CORRECT LEVEL YES IS 4–20 MA OUTPUT CORRECT? • CHECK 4–20 MA PROGRAM SETTINGS NO • MAKE SURE UNIT IS READING CORRECT LEVEL • LOOP POWER IS SUPPLIED BY 344/345 MAKE SURE LOAD IS IN PASSIVE MODE • LOOP RESISTANCE MUST BE
344-0442-100 价格&库存

很抱歉,暂时无法提供与“344-0442-100”相匹配的价格&库存,您可以联系我们找货

免费人工找货