0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
804-R010-230

804-R010-230

  • 厂商:

    MAGNETROL

  • 封装:

  • 描述:

    804-R010-230 - Kotron® Sentinel Model 804 RF Level Transmitter - Magnetrol International, Inc.

  • 数据手册
  • 价格&库存
804-R010-230 数据手册
Kotron® Sentinel Model 804 RF Level Transmitter DESCRIPTION The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display and keypad simplify calibration and setup of the instrument. Powerful diagnostics check all functions of the system, simplifying troubleshooting. MagneCal™ offers the user the greatest improvement in RF Capacitance—one small level change is needed to calibrate. FEATURES • Two or four SPDT relays with gold flash contacts for alarm and control operation. • Optional intrinsically safe probe circuitry (with on-board barriers). • 16-button keypad and 2 × 16 LCD display. • Isolated 4–20 mA output includes an active/passive mode. • Relays can be configured for sequential or lead/lag pump control. • One small level change (2% of span) needed for initial probe calibration. • 4–20 mA and up to eight control points can be programmed with no level change. • Powerful self-diagnostics check the system, including probe. • Relay #1 can be dedicated as a diagnostics relay. APPLICATIONS • Continuous level measurement • Interface measurement • Hydrocarbons and solvents • Slurries • Acids • High temperature/pressure liquids TECHNOLOGY The amount of capacitance developed in any vessel is determined by: the size (surface area) of the probe; the distance from the probe to its ground reference; and the dielectric constant of the medium being measured. Considering that the probe’s mounting position is fixed and the dielectric of the medium is constant, then the amount of capacitance developed in any vessel becomes dependent upon the amount of the probe which is covered with media. As the media rises and falls in the tank, the amount of capacitance developed between the probe and the ground reference also changes. The capacitance signal is converted to a frequency proportional to the change in level. The amplifier then converts this digital signal into an isolated 4–20 mA analog output signal. SPECIFICATIONS Supply voltage 120 VAC, 50/60 Hz (+10 – 15%) 240 VAC, 50/60 Hz (+10 – 15%) 24 VDC (±10%) 15 VA nominal -40° to +160° F (-40° to +70° C) 99% non-condensing (electronics) Better than ±1.0% ±0.1% ±0.5% ±0.01%/° F (±0.018/° C) 16-button keypad 2 line × 16 character LCD display 4-20 mA (isolated), reversible, 1000 ohms max. loop resistance 4-20 mA (isolated), reversible, loop resistance dependent on power supply 5 pF minimum; 50,000 pF maximum 0-90 seconds 0-50,000 pF 0.5 pF minimum; 50,000 pF maximum 0-90 seconds level rising, level falling, both 10 amp @ 120/240 VAC resistive 10 amp @ 30 VDC resistive 0.5 amp @ 125 VDC resistive 2500 feet (760 meters) 800 feet (240 meters) Power consumption Ambient temperature range Humidity Accuracy Repeatability Linearity Temperature effect Operator interface: Data entry Display Continuous Output: Active signal Passive signal Range Damping Discrete output (SPDT) with gold flash contacts: Set point range Adjustable differential range Time delay Relay output: AC DC Maximum remote cable length: Standard Intrinsically safe 2 AGENCY Agency FM APPROVALS Protection Method Explosion proof Area Classification Class I Div. 1, Groups B, C & D Class II, Div. 1, Groups E, F, & G Class III NEMA 4X, IP65 Integral units Class I Div. 1, Groups B, C & D Class II, Div. 1, Groups E, F, & G Class III NEMA 4X, IP65 Electronics Class I Div. 1, Groups B, C & D Class II, Div. 1, Groups E, F, & G Class III NEMA 4X, IP65 Remote probe Class I Div. 1, Groups A, B, C & D Class II, Div. 1, Groups E, F, & G Class III, NEMA 4X, IP65 Approved Model 804-XXXX-23X 804-XXXX-33X Insulated rigid probes only 804-XXXX-53X 804-XXXX-63X Explosion proof with intrinsically safe probe circuit CSA 804-XXXX-23X 804-XXXX-33X Insulated rigid probes only 804-XXXX-53X 804-XXXX-63X Explosion proof Explosion proof Œ with intrinsically safe probe circuit Class I Div. 1, Groups C & D Class II, Div. 1, Groups E, F, & G Class III TYPE 4X Integral units with IS probe circuit Class I Div. 1, Groups B, C & D Class II, Div. 1, Groups E, F, & G Œ Class III TYPE 4X Electronics Class I Div. 1, Groups B, C & D Class II, Div. 1, Groups E, F, & G Œ Class III TYPE 4X Remote probe Class I Div. 1, Groups A, B, C & D Class II, Div. 1, Groups E, F, & G Œ Class III TYPE 4X Œ For Class II, Groups E & F insulated probes must be used These units have been tested to EN 50081-2 and EN 50082-2 and are in compliance with the EMC Directive 89/336/EEC. 3 DIMENSIONAL INCHES (mm) B 1 Rotation clearance A SPECIFICATIONS B 1 Rotation clearance A C G G C G G plugged D plugged D 2 Optional mounting flange 2 Optional mounting flange .1875 (5) .2500 (6) 2.95 (75) Integral Mount with Flexible Probe .50 (13) .625 (16) Integral Mount with Standard Rigid Probe 4.63 (118) Dia. 3.00 (76) 2.75 (70) 3.23 (82) 3/4" NPT Optional mounting flange 2 .50 (13) .625 (16) Rigid Probe 4 DIMENSIONAL INCHES (mm) SPECIFICATIONS B 1 Rotation clearance A (cont.) E G G 2 Holes .38 (10) Dia. 2.00 (51) 2.37 (60) plugged F 3.00 (76) 3.50 (89) 3 Remote Mount 1/2" NPT or 3/4" NPT 4.63 (118) Dia. 3.00 (76) 2.75 (70) 4.67 (119) 3/4" NPT Optional mounting flange 2 .1875 (5) .2500 (6) 2.95 (75) Flexible Probe Outline Dimensions Housing NEMA 4X/7/9 Aluminum Conduit Connections NEMA 4X/7/9 (remote probe housing) Single conduit NEMA 4X/7/9 Dual conduit 3 A 3.87 (98) G ⁄4" NPT B 5.93 (151) C 10.89 (276) Standard Rigid Probe D E 2.44 (61) 13.44 (341) F 4.11 (104) C 12.33 (313) Flexible Probe D E 4.71 (119) 13.44 (341) F 4.11 (104) 1" NPT NOTES: Œ Allow 8.00 (200) overhead clearance for cover removal.  Standard process connection is 3⁄4" NPT. Consult probe bulletin (50-125) for flange and other probe connections. Ž Probe/amplifier connecting cable to be shielded, twisted pair, 22-gauge stranded conductors, Magnetrol part number 009-7146-001; 2500 feet (760 m) maximum; 800 feet (240 m) maximum for intrinsically safe models. 5 MODEL NUMBER Models available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). BASIC MODEL 804 Sentinel RF Level Transmitter ELECTRONIC HOUSING R Y NEMA 4X/7/9 aluminum, 1" NPT NEMA 4X/7/9 aluminum, 1" NPT with 316 SS, remote housing INPUT POWER 0 1 2 120 VAC 240 VAC 24 VDC ANALOG OUTPUT/COMMUNICATIONS 1 5 4-20 mA 4-20 mA with RS-485 (Modbus) ALARM/CONTROL OUTPUT 0 C D No relays (2) 10 amp SPDT relays with gold flash contacts (4) 10 amp SPDT relays with gold flash contacts MOUNTING 2 3 5 6 Integral explosion proof Remote explosion proof Integral explosion proof w/IS safe probe circuit Remote explosion proof w/IS safe probe circuit Œ Œ Not available with Electronic housing code Y 8 0 4 3 0 PROBES A full range of rigid and flexible probes, for conductive and non-conductive process media, is available in various lengths and materials of construction. For further information on probe assemblies, refer to bulletin 50-125. REMOTE CABLE Remote cable should be shielded, twisted pair, 22-gauge stranded conductors and may be ordered using Magnetrol part number 009-7146-001. Cable length in feet must be specified at time of order; 2500 feet (760m) maximum; 800 feet (240 m) maximum for intrinsically safe models. 6 NOTES 7 QUALITY The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol’s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product and service quality available. ESP Several Kotron Model 804 RF transmitters are available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, simply match the color coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. Expedite Ship Plan WARRANTY All Magnetrol electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. For additional information, see Instruction Manual 50-604. 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com 145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306 Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317 Copyright © 2010 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. BULLETIN: 50-118.3 EFFECTIVE: February 2001 SUPERSEDES: September 2000
804-R010-230 价格&库存

很抱歉,暂时无法提供与“804-R010-230”相匹配的价格&库存,您可以联系我们找货

免费人工找货