Kotron® Model 811 RF Point Level Switch
DESCRIPTION
The Kotron® Model 811 Level Switch offers the user great flexibility. The switch can be used either as a single alarm relay with narrow differential or for control purposes with an adjustable differential. Using the proven RF Capacitance technology, the Model 811 provides reliable operation for a broad range of applications.
FEATURES
• Useable for both narrow differential (alarm) and wide differential (control) • Intrinsically safe probe circuitry yields extra degree of safety even with bare probes in hazardous media • Remote mounting up to 150 feet (45 meters) with no preamplifier on the probe provides protection from high process temperatures or heavy vibration • 10-amp DPDT relay provides flexibility for both alarm and control applications • Guard circuitry and probe reject buildup of media • Useable with all Kotron probes for application flexibility • LED shows relay status and aids in calibration and troubleshooting • 0 to 120 second time delay feature eliminates relay chatter due to turbulence • Field selectable high level/low level failsafe • Conformally coated circuit boards reduce circuit problems due to moisture and fungus
APPLICATIONS
• Clean or dirty liquids • Viscous liquids • Light slurries • Corrosive liquids • High temperature/pressure liquids • Hydrocarbons and solvents • Acids and caustics • Foods and beverages
TYPICAL
APPLICATION
Pump/Valve
Control
The Model 811 handles alarm applications as well as pump/valve control applications with a wide or adjustable differential.
Pump control
Coating
Rejection
Conductive coating
The Model 811 provides rejection of conductive buildup by utilizing a guarded probe. Coating rejection circuit is standard on all units.
Intrinsically
Safe
Non-hazardous Area
Hazardous Area
The Model 811-1X06-E0X is inherently intrinsically safe when the main amplifier is mounted in a non-hazardous area. Barriers are included in the 811 electronics eliminating the need for separate barriers.
811-1X06-E0X
Intrinsically safe circuit
2
TECHNOLOGY
The amount of capacitance developed in any vessel is determined by the size (surface area) of the probe, the distance from the probe to its ground, and the dielectric of the medium being measured. Considering that the probe’s mounting position is fixed and that the dielectric value of the medium is constant, then the amount of capacitance developed in any vessel becomes dependent upon the amount of the probe which is covered by the media. As media rises and falls in the tank, the amount of capacitance developed between the sensing probe and the ground also rises and falls. This change in capacitance is compared to the adjustable set point and changes the state of a relay when they are equal.
SPECIFICATIONS
Supply voltage 120 VAC, 50–60 Hz (+10%, -15%) 240 VAC, 50–60 Hz (+10%, -15%) 24 VDC (±10%) 12 VDC (±10%) Power consumption 120 or 240 VAC Less than 5 volt-amps 12 or 24 VDC 1 watt maximum Zero range Adjustable differential Output relays (DPDT) with gold flash contacts 0 pF minimum to 1000 pF maximum 0.5 to 700 pF AC 10 amp @ 120/240 VAC resistive DC 10 amp @ 30 VDC resistive DC 0.5 amp @ 125 VDC resistive Response time Repeatability Ambient temperature Operating process pressure/temperature 100 milliseconds Better than 1.0% Electronics -40° to +160° F (-40° to +70° C) Dependent upon probe selection; refer to probe bulletin 50–125
Guarded probe 8XD-AAXA-0XX 3500 psig @ +100° F (240 bar @ +40° C) Temperature coefficient of set point -40° to +160° F (-40° to +70° C) ±.01% per degree F of setpoint (±.018% per degree C of setpoint)
3
DIMENSIONAL
INCHES (mm)
SPECIFICATIONS
Rotation clearance: 2.63 (66) 3/4" PT Conduit connection (plugged)
➀ 9.33 (247)
3/4" NPT Conduit connection
Optional mounting flange
3/4" NPT thread
Rotation clearance: 2.63 (66)
Rotation clearance: 3.00 (76) 6.86 (174)
➀ 7.75 (197)
3/4" NPT Conduit connection 2.37 (60)
3/4" NPT Conduit connection 3/4" NPT Conduit connection (plugged) 4.11 (104) 3/4" NPT Thread
2 Holes .38 (10) dia. 2.00 (51)
3.00 (76) 3.75 (95)
3.50 (89)
.375 (10)
➁
1/2" NPT (opt.) 3/4" NPT (std.) Transducer/Amplifier cable connection
18" (455) or 36" (915)
Integral Mount with Guarded Probe
.375 (10)
Remote Mount with Guarded Probe
Rotation clearance: 2.63 (66) 3/4" NPT Conduit connection (plugged) Optional mounting flange Rotation clearance: 2.63 (66) 3/4" NPT Conduit connection 3/4" NPT Conduit connection (plugged)
3.75 (95)
➀ 8.45 (215)
3/4" NPT Conduit connection
Rotation clearance 3.00 (76) 5.98 (152)
➀ 7.75 (197)
3/4" NPT Conduit connection
¬
2 Holes .38 (10) dia.
2.37 (60)
2.00 (51)
3.00 (76) 3.50 (89)
➂
.50 (13) Bare probes .625 (16) Insulated probes
➁
1/2" NPT (opt.) 3/4" NPT (std.) Transducer/Amplifier cable connection .50 (13) Bare probes .625 (16) Insulated probes
Integral Mount with Standard Rigid Probe Remote Mount with Standard Rigid Probe
4
DIMENSIONAL
INCHES (mm)
SPECIFICATIONS
Rotation clearance: 2.63 (66)
➀ 9.89 (251)
3/4" NPT Conduit connection .1875 (5) .2500 (6) 1.32 (34) 4.87 (124) 5.00 (127) .79 (19)
3/4" NPT Conduit connection (plugged) Optional mounting flange
➂
Optional anchor assembly 2.95 (75) .79 (19) Optional weight
Integral Mount with Flexible Probe
Rotation clearance: 2.63 (66)
Rotation clearance 3.00 (76) 3/4" NPT Conduit connection 3/4" NPT Thread .1875 (5) .2500 (6) 1.32 (34) 4.87 (124) 5.00 (127) .79 (19)
3/4" NPT Conduit connection 2.37 2 Holes (60) .38 (10) dia. 3.00 2.00 (76) (51) 3.50 (89)
➀ 7.75 (197)
7.42 (188)
3/4" NPT Conduit connection (plugged) 3.75 (95) 1/2" NPT (opt.) 3/4" NPT (std.) Transducer/ Amplifier cable connection
➂
2.95 (75)
Optional anchor assembly
➁
.79 (19) Optional weight
Remote Mount with Flexible Probe
NOTES:
Allow 6.00 (152) overhead clearance for removal of cover.
Standard process connection is 3⁄4" NPT. Consult probe brochure (50-125) for flange and other probe connections.
Probe/Amplifier Connecting Cable to be triaxial. Magnetrol part number 037-3180-XXX standard or part number 037-3184-XXX high temperature.
5
AGENCY
AGENCY
APPROVALS
PROTECTION METHOD AREA CLASSIFICATION
APPROVED MODEL
FM
811-1X05-E0X 811-1X06-E0X with probe models: 041-5XXX-XXX and 8XX-XXX-XXX 811-1X06-E0X (Remote) with probe models: 041-5XXX-XXX and 8XX-XXX-XXX
Explosion Proof
Explosion proof with intrinsically safe probe circuit Class I, Div. 1, Groups C & D Class II, Div. 1, Groups E, F, & G NEMA 4X
Intrinsically Safe
Remote probe: Class I, Groups A, B, C, & D Class II, Div. 1, Groups E, F, & G Class III, NEMA 4X
CSA
811-1X05-E0X 811-1X06-E0X with probe models: 041-5XXX-XXX and 8XX-XXX-XXX 811-1X06-E0X (Remote) with probe models: 041-5XXX-XXX and 8XX-XXX-XXX
Explosion Proof
Explosion proof with intrinsically safe probe circuit Class I, Div. 1, Groups C & D Class II, Div. 1, Groups E, F, & G
(Bare probes not approved for Groups E & F)
TYPE 4X Intrinsically Safe Remote probe: Class I, Div. 1, Groups A, B, C, & D Class II, Div. 1, Groups E, F, & G
(Bare probes are not approved for Groups E & F)
Class III, TYPE 4X
These units have been tested to EN 50081-2 and EN 50082-2 and are in compliance with the EMC Directive 89/336/EEC.
6
MODEL
FM & CSA
NUMBER
APPROVED
Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP).
Applies only if Model 811 and selected probe both qualify for ESP.
BASIC MODEL 811 Kotron RF Capacitance Level Switch
INPUT POWER 0 120 VAC 1 240 VAC 2 24 VDC 3 12 VDC
MOUNTING 5 Integral 6 Remote
HOUSING NEMA 4X/7/9 Groups C & D, aluminum, E 3 ⁄4" NPT dual conduit Y NEMA 4X/7/9 Groups C & D, stainless steel, 3 ⁄4" NPT single conduit
PROBE 0 Probe ordered separately 1 18" (455 mm) guarded probe 2 36" (915 mm) guarded probe
8
1
1
1
0
0
PROBES
A full range of rigid and flexible probes for conductive and non-conductive materials is available in various lengths and materials of construction. For further information on probe assemblies, refer to bulletin 50-125.
REMOTE
CABLE
Specify connecting cable by exact length between 10 and 150 feet. Standard cable (+175° F / +80° C) Magnetrol part number 037-3180-XXX (length in feet). High temperature cable (+390° F / +200° C) Magnetrol part number 037-3184-XXX (length in feet).
7
QUALITY
The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol’s quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product and service quality available.
ESP
Expedite Ship Plan
Several Kotron Model 811 RF Point Switches are available for quick shipment, usually within one week after factory receipt of a purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, simply match the
color coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options.
WARRANTY
All Magnetrol electronic level and flow controls are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products.
For additional information, see Instruction Manual 50-608.
5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com 145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306 Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317
Copyright © 2010 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
Magnetrol & Magnetrol logotype and Kotron are registered trademarks of Magnetrol International.
BULLETIN: 50-103.7 EFFECTIVE: May 2010 SUPERSEDES: April 2005