0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
910-A1A0-003

910-A1A0-003

  • 厂商:

    MAGNETROL

  • 封装:

  • 描述:

    910-A1A0-003 - Echotel® Model 910 Ultrasonic Level Switch - Magnetrol International, Inc.

  • 数据手册
  • 价格&库存
910-A1A0-003 数据手册
Echotel® Model 910 Ultrasonic Level Switch DESCRIPTION Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit hub electronics houses a 10-amp DPDT gold flash relay that is field selectable for high or low level fail-safe applications. There are no moving parts that come in contact with the medium. The Echotel Model 910 is an integrally mounted system, comprised of surface mount electronics and a 316 stainless steel transducer. Hazardous area location approvals are available from FM, CSA, and ATEX. FEATURES • Measures level within 0.25" (6 mm) from the end of the tip-sensitive transducer gap • 10-amp DPDT gold flash or 5-amp DPDT hermetically sealed relay • Surface mount conformal coated electronics • FM, CSA, and ATEX approved for hazardous locations • Variety of mounting options including NPT and BSP threaded, flanges and hygienic connections • No calibration required • 316 stainless steel transducer • May be mounted either horizontally or vertically • Compact NEMA 4X/7/9 dual conduit hub cast aluminum electronics housing • Available in 14 standard actuation lengths from 1" to 96" (2.5 to 244 cm) • Two-year product warranty APPLICATIONS • • • • • • • Water and wastewater Food and beverage Pulp and paper Petrochemical Power Pharmaceutical Chemical TECHNOLOGY The Model 910 Level Switch uses ultrasonic energy to detect the presence or absence of liquid in a 316 SS tip sensitive transducer gap. The basic principle behind ultrasonic contact technology is that high-frequency sound waves are easily transmitted across a transducer gap in the presence of a liquid medium, but are severely attenuated when the gap is dry. The Model 910 uses an ultrasonic frequency of 3 MHz to perform this liquid level measurement in a wide variety of process media and application conditions. The transducer uses a pair of piezoelectric crystals that are encapsulated in epoxy at the tip of the transducer. The crystals are made of a ceramic material, such as lead zirconate. The transmit crystal converts an electrical signal from the Model 910 electronics into an ultrasonic signal. When liquid is present in the gap, the receive crystal is able to sense the ultrasonic signal from the transmit crystal and convert it back to an electrical signal. This signal is sent to the electronics to indicate the presence of liquid in the transducer gap. When there is no liquid present, the ultrasonic signal is attenuated, and the receive crystal is not able to sense the sound waves from the transmit crystal. Ultrasonic transducer Transmit crystal Receive crystal Ultrasonic signal transmission across transducer gap Filling line High alarm Low alarm High alarm Pump protection Low alarm Pump Typical applications and mounting positions ELECTRICAL Power Supply: SPECIFICATIONS 120 VAC (+10%/-15%), 50/60 Hz 240 VAC (+10%/-15%), 50/60 Hz 24 VDC (±10%) Power Consumption: Relay Output: Gold flash DPDT Œ: 10 amps @ 120 VAC, 10 amps @ 240 VAC 10 amps @ 24 VDC, 0.5 amps @ 125 VDC Hermetically sealed DPDT: 5 amps @ 120 VAC, 3 amps @ 240 VAC 5 amps @ 24 VDC 2.5 VA nominal Repeatability: Fail-safe: Calibration: Ambient Temperature: Process Temperature: Shock: Vibration: Operating/Non-Operating Pressure: 0.078" (2 mm) Field selectable high or low None required Electronics: -40° to +158° F (-40° to +70° C) Transducer: -40° to +250° F (-40° to +121° C) ANSI/ISA-S71.03 Class SA1 ANSI/ISA-S71.03 Class VC2 800/1500 psig (55/103 bar) Œ Gold flash DPDT relay is rated at 8 amps when used with housing codes 5 or P 2 SWITCH MODEL NUMBER Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP) HOUSING A Y P 5 Aluminum sand cast with 3⁄4" NPT dual conduit, FM or CSA approvals 316 stainless steel with 3⁄4" NPT single conduit, FM or CSA approvals Aluminum sand cast with 3⁄4" NPT dual conduit, FM, CSA, and ATEX approvals 316 stainless steel with 3⁄4" NPT single conduit, ATEX approval TRANSDUCER UNIT OF LENGTH 1 M English (actuation length in inches) Metric (actuation length in centimeters) PROCESS CONNECTION A 2 9 3 4 1 C D E F G ⁄4" NPT 1" NPT 1" BSP 11⁄2" hygienic 16 AMP fitting (compatible with Tri-Clover® Tri-Clamp®) 2" hygienic 16 AMP fitting (compatible with Tri-Clover Tri-Clamp) 1" 150 lb. ASME raised face flange 11⁄2" 150 lb. ASME raised face flange 2" 150 lb. ASME raised face flange 1" 300 lb. ASME raised face flange 11⁄2" 300 lb. ASME raised face flange 2" 300 lb. ASME raised face flange 3 INPUT POWER 0 1 2 H J K 120 240 24 120 240 24 VAC with 10-amp DPDT gold flash relay VAC with 10-amp DPDT gold flash relay VDC with 10-amp DPDT gold flash relay VAC with 5-amp DPDT hermetically sealed relay VAC with 3-amp DPDT hermetically sealed relay VDC with 5 amp DPDT hermetically sealed relay ACTUATION LENGTH 1" to 96" in 1" increments (with Transducer Unit of Length code 1) Example: 4 inches = 004 Œ Ž 3 cm to 244 cm in 1 cm increments (with Transducer Unit of Length code M) Examples: 6 centimeters = 006  Ž Available ESP lengths  : 1", 2", 4", 6", 8", 12", 16", 22" 9 1 0 Œ 1" (code 001) minimum with NPT process connections, 2" (code 002) minimum with hygienic or ASME flanged process connections. Ž Consult factory for longer lengths.  2.5 cm (code 003) minimum with NPT process connections, 5 cm (code 005) minimum with 1" BSP, or hygienic or ASME flanged process connections.  Consult factory for ESP metric length codes. 3 AGENCY AGENCY APPROVALS MODEL APPROVED APPROVAL CATEGORY APPROVAL CLASSES FM 910-XXXX-XXX Explosion Proof 910-XXXX-XXX Non-Incendive CSA 910-XXXX-XXX Explosion Proof 910-XXXX-XXX Non-Incendive ATEX 910-5XXX-XXX 910-PXXX-XXX Class I, Div. 1; Groups B, C & D Class II, Div. 1; Groups E, F, & G Class III, NEMA Type 4X, T6 Class I, Div. 2; Groups A, B, C, & D Class II, Div. 2; Groups F & G Class III, NEMA Type 4X, T5 Class I, Div. 1; Groups C & D Class II, Div. 1; Group E, F, & G Class III, Type 4X, T6 Class I, Div. 2; Groups A, B, C, & D Class II, Div. 2; Groups E, F, & G Class III, Type 4X, T5 II 1/2 G EEx d II C T6 / EEx e II T6 Note: Consult factory for Brazilian INMETRO BR-Ex d IIC T6 IP66 approval. These units have been tested to EN 50081-2 and EN 50082-2 and are in compliance with the EMC Directive 89/336/EEC. DIMENSIONAL INCHES 4.63 (117) Dia. SPECIFICATIONS 4.63 (117) Dia. 4.63 (117) Dia. 3.44 (87) Rotation clearance 3.44 (87) Rotation clearance 3/4" (MM) 3.00 Rotation (76) clearance 3/4" 4.63 (117) Dia. 3/4" NPT (plugged) 3.44 (87) Rotation clearance 2.75 (70) 3/4" NPT 4.48 (113) 6.25 (158) 3/4" 2.75 (70) 6.25 (158) 4.48 (113) NPT plugged 2.75 (70) 3/4" 4.48 (113) 6.25 158) NPT plugged 2.75 (70) 3/4" 4.48 (113) NPT 3.50 Optional (88) mounting flange NPT Optional mounting flange NPT tank connection Actuation point .25 (6) 3.50 (88) NPT .25 (6) 1" BSP tank connection Actuation point .25 (6) NPT tank connection Actuation point .25 (6) 3/4" 3/4" Actuation length ➀➁ Actuation length ➀➁ Actuation length ➁ Actuation point .25 (6) Actuation length ➀➁ .875 (22) Dia. .875 (22) Dia. .875 (22) Dia. .875 (22) Dia. NEMA 4X/7/9, 316 SS hsg 3 ⁄4" NPT single conduit NEMA 4X/7/9, aluminum hsg 3 ⁄4" NPT dual conduits NEMA 4X/7/9, aluminum hsg 3 ⁄4" NPT dual conduit (w/1" BSP process conn.) NEMA 4X/7/9, aluminum hsg 3 ⁄4" NPT dual conduit (with hygienic flange) QUALITY All Magnetrol Model 910 Level Switches are warranted free of defects in materials or workmanship for two full years from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair For additional information, see Instruction Manual 51-604. or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com 145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306 Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317 Copyright © 2011 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. Magnetrol & Magnetrol logotype and Echotel® are registered trademarks of Magnetrol International. Tri-Clamp® is a registered trademark of Ladish Co. Tri-Clover® is a registered trademark of Tri-Clover, Inc. BULLETIN: 51-105.17 EFFECTIVE: February 2011 SUPERSEDES: July 2010
910-A1A0-003 价格&库存

很抱歉,暂时无法提供与“910-A1A0-003”相匹配的价格&库存,您可以联系我们找货

免费人工找货