0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
T52-1E2A-BKP

T52-1E2A-BKP

  • 厂商:

    MAGNETROL

  • 封装:

  • 描述:

    T52-1E2A-BKP - Side Mounting Liquid Level Switches - Magnetrol International, Inc.

  • 数据手册
  • 价格&库存
T52-1E2A-BKP 数据手册
Side Mounting Liquid Level Switches DESCRIPTION Magnetrol side mounting controls mount horizontally to any tank or vessel through a threaded or flanged pipe connection. Standard models are normally equipped with a single switch mechanism for high or low level alarm or control applications. Tandem models, with two switch mechanisms, are available for two-stage applications. FEATURES • Body material of cast iron, carbon steel or stainless steel • 300 series stainless steel float and trim • Threaded or flanged mounting • Specific gravity ratings down to 0.50 • Process temperatures to +1000° F (+538° C) • Choice of float size: • 21⁄2" (64 mm) • 21⁄2" × 4" (64 × 102 mm) • • • 3" (76 mm) 31⁄2" (89 mm) 3" × 5" (76 × 127 mm) APPLICATIONS • Fuel tanks • Day tanks • Flash tanks • Scrubbers • Cooling towers • Dump valve controls • Condensate receivers • Boilers • Deaerators • Holding tanks • Field-adjustable level differential • Choice of switch mechanism: Dry contact Hermetically sealed Pneumatic • Choice of switch mechanism enclosure: NEMA 1 carbon steel for pneumatic TYPE 4X/7/9, Class I, Div. 1, Group C & D, polymer coated aluminum TYPE 4X/7/9, Class I, Div. 1, Group B, polymer coated aluminum TECHNOLOGY Side mounting units employ permanent magnetic force as the only link between the float and the switching element. As the pivoted float follows liquid level changes, it moves a magnetic sleeve Œ into or out of the field of a switch actuating magnet  causing switch operation. A nonmagnetic barrier tube Ž effectively isolates the switch mechanism from the controlled liquid. Snap switch 3 Pivot 1 2 Pivot Return spring Float Falling level Rising level AGENCY AGENCY FM APPROVALS APPROVED MODEL All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 Class I, Div 1, Group B APPROVAL CLASSES Class I, Div 1, Groups C & D Class II, Div 1, Groups E, F & G Class I, Div 1, Groups B, C & D Class II, Div 1, Groups E, F & G Class I, Div 2, Groups B, C & D Class I, Div 1, Groups C & D Class II, Div 1, Groups E, F & G Class I, Div 1, Groups B, C & D Class II, Div 1, Groups E, F & G ATEX II 2 G EEx d IIC T6 94/9/EC IEC Ex Ex d IIC T6 IP 66 Installation Category II Pollution Degree 2 CSA All with a Series H1, HS, F, 8 or 9 electric switch mechanism and a housing listed as CSA TYPE 4X All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 All with an electric switch mechanism and a housing listed as TYPE 4X/7/9 Class I, Div 1, Group B All with an electric switch mechanism and an ATEX housing Œ ATEX / IEC Ex  CE Low Voltage Directives 2006/95/EC Per Harmonized Standard: EN 61010-1/1993 & Amendment No. 1 Œ Dual stage units with “HS” switches are not ATEX approved  IEC Installation Instructions: The cable entry and closing devices shall be Ex d certified suitable for the conditions of use and correctly installed. For ambient temperatures above +55° C or for process temperatures above +150° C, suitable heat resistant cables shall be used. Heat extensions (between process connection and housing) shall never be insulated. Special conditions for safe use: When the equipment is installed in process temperatures higher than +85° C the temperature classification must be reduced according to the following table as per IEC60079-0. Maximum Process Temperature < 85° C < 100° C < 135° C < 200° C < 300° C < 450° C Temperature Classification T6 T5 T4 T3 T2 T1 These units are in conformity with IECEx KEM 05.0020X Classification Ex d IIC T6 Tambient -40° to +70° C 2 SPECIFICATIONS SWITCH MECHANISMS AND ENCLOSURES SERIES B, C, D & R DRY CONTACT SWITCHES • Designs for AC and DC current applications • Process temperatures to +1000° F (+538° C) SERIES F, HS, H1, 8 & 9 HERMETICALLY SEALED SWITCHES • Ideal for use in salt and other corrosive atmospheres • Entire switch mechanism and contacts are contained within a positively pressurized capsule with Series “HS” and “H1” • Process temperatures to +1000° F (+538° C) SERIES J & K PNEUMATIC SWITCHES • Suited for applications where electrical power is not available • Bleed and non-bleed designs • Process temperatures to +400° F (+204° C) SWITCH ENCLOSURES • TYPE 4X/7/9 aluminum enclosures • Designed to meet Class I, Div. 1, Groups C & D and Class I, Div. 1 Group B • Optional housing heaters and drains available for some enclosures • Pneumatic switch mechanisms available with a NEMA 1 enclosure BASIC ELECTRICAL RATINGS Voltage 120 VAC 240 VAC 24 VDC 120 VDC 240 VDC B 15.00 15.00 6.00 0.50 0.25 C Switch Series and Non-Inductive Ampere Rating D F HS H1 R 8 10.00 — 10.00 10.00 3.00 0.25 — 4.00 0.30 — 5.00 5.00 5.00 0.50 0.25 1.00 1.00 1.00 0.40 — 1.00 1.00 1.00 0.40 — 1.00 — 3.00 — — 9 — — 0.50 — — 15.00 15.00 10.00 1.00 0.50 3 LEVEL INCHES DIFFERENTIAL (MM) ADJUSTMENT Inches Differentials Obtainable   Approx. Jam Nut Setting Ž Float Stem Length Model Œ 8.00 12.00 18.00 26.00 A B T52 1.25 4.75 1.00 2.62 1.25 5.81 1.25 3.50 1.75 7.00 1.75 5.00 2.00 8.12 1.62 5.12 2.50 10.25 2.50 7.38 2.88 11.56 2.62 7.50 3.50 14.50 3.50 10.50 4.00 16.12 3.75 10.75 0.81 1.31 0.81 1.31 0.81 1.31 0.62 1.12 0.03 1.06 0.03 1.06 0.03 1.06 0.03 0.69 The level differential may be adjusted by repositioning the jam nuts on the magnetic sleeve stem as shown below. Refer to the charts at right for the minimum and maximum levels obtainable. Upper jam nuts Guide washer B A A. top of attraction sleeve to top of stem Magnetic sleeve stem Magnetic sleeve Lower jam nuts B. top of attraction sleeve to bottom of bottom jam nut Pivot Pivot CL of control High level Differential Low level Float Min. Max. Min. T63 Max. Min. T62 (Threaded) Max. Min. T62 (Flanged) Max. Millimeters Float stem length minus approx. 3/4" Differentials Obtainable   Float Stem Length Model Œ 230 305 457 660 32 121 25 67 32 148 32 89 44 178 44 127 51 206 41 130 64 260 64 187 73 294 67 191 89 368 89 267 102 409 95 273 Approx. Jam Nut Setting Ž A 21 33 21 33 21 33 16 28 B 0.8 27 0.8 27 0.8 27 0.8 18 Notes: Œ All models are factory set at minimum differential unless otherwise specified.  To maintain maximum differential, nozzle length “L” (Fig. 3) must not exceed: 2.38" (60 mm) model T52; 1.19" (30 mm) model T63; 2.50" (64 mm) model T62 threaded; or 3.50" (89 mm) model T62 flanged. Ž Dimensions given are approximate and will vary slightly with each unit.  Consult factory for differentials of models not shown. Min. T52 Max. Min. T63 Max. Min. T62 (Threaded) Max. Min. T62 (Flanged) Max. DIMENSIONAL INCHES (MM) SPECIFICATIONS 5.93 (151) 4.29 (108) 10.69 (272 ) 5.93 (151) 4.29 (108) Single switch models only Conduit Connections A Electrical Switches TYPE 4X/7/9: 1" NPT Group B: 1" NPT Pneumatic Switches 1 NEMA 1: ⁄4" NPT Note: Allow 8.00 (203) overhead clearance for cover removal. 10.69 (272 ) 6.13 6.98 (156) (177) A 6.13 6.98 (156) (177) A This dimension equals stem length plus float length, minus 3.38 (86). This dimension equals stem length plus float length, minus 2.50 (64). Model T52 with Flanged Body Model T63 with Threaded Body 5.93 (151) 4.29 (108) 10.69 (272) 5.93 (151) 4.29 (108) 3.12 (79) Dia. Hole 45° 10.69 (272) 6.13 (156) A 6.13 (156) A 6.98 (177) 6.98 (177) Four 1/2" studs extending 1.25 (32) from tank on 4.62 (117) bolt circle. 45° Flange This dimension equals stem length plus float length, minus 2.25 (57). This dimension equals stem length plus float length, minus 3.00 (76). 4 Model T62 with Threaded Body Model T62 with Flanged Body LEVEL DIFFERENTIAL VS. MOUNTING NOZZLE LENGTH The tables below may be used to determine the maximum level travel (differential) available between “Switch on” and “Switch off” actuations with mounting nozzles of different lengths. The differentials given occur with the minimum tank opening diameter listed for each model and are applicable to standard controls. Conduit outlet (ref.) Min. nozzle opening C of control L Switch actuates rising level Level differential Switch actuates falling level Float L Inches Nozzle Length (Dim. L) Maximum Level Differential Available with Several Nozzle Lengths  Model T52 with 3.12" Model T63 with 2.31" Model T62 Threaded with 3.06" Model T62 Flanged with 2.88" Diameter Minimum Tank Diameter Minimum Tank Diameter Minimum Tank Diameter Minimum Tank Nozzle Opening  Nozzle Opening  Nozzle Opening Ž Nozzle Opening  Float Stem Length Float Stem Length Float Stem Length Float Stem Length 8.00 12.00 18.00 26.00 8.00 12.00 18.00 26.00 8.00 12.00 18.00 26.00 8.00 12.00 18.00 26.00 4.75 4.00 — — — — 7.00 5.62 4.25 3.50 2.88 — 10.25 8.12 6.25 5.12 4.25 3.62 14.50 11.62 8.88 7.25 6.00 5.12 2.62 1.88 — — — — 5.00 3.50 2.75 2.38 2.00 — 7.38 5.25 4.12 3.38 2.88 2.50 10.50 7.50 5.88 4.88 4.12 3.50 5.81 4.38 1.50 — — — 8.12 6.12 4.69 3.81 3.19 — 11.56 8.69 6.69 5.44 4.56 3.94 16.12 12.19 9.31 7.56 6.38 5.44 3.50 3.25 — — — — 5.12 4.75 3.75 3.00 2.50 — 7.50 7.00 5.38 4.50 3.75 3.25 10.75 10.00 7.75 6.25 5.38 4.62 Œ 2.00 4.00 6.00 8.00 10.00 12.00 Millimeters Nozzle Length (Dim. L) Maximum Level Differential Available with Several Nozzle Lengths  Model T52 w/79 mm Model T63 w/59 mm Model T62 Threaded w/78 mm Model T62 Flanged w/73 mm Diameter Minimum Tank Diameter Minimum Tank Diameter Minimum Tank Diameter Minimum Tank Nozzle Opening  Nozzle Opening  Nozzle Opening Ž Nozzle Opening  Float Stem Length Float Stem Length Float Stem Length Float Stem Length 203 305 457 660 203 305 457 660 203 305 457 660 203 305 457 660 121 102 — — — — 178 143 108 89 73 — 260 206 159 130 108 92 368 295 226 184 152 130 67 48 — — — — 127 89 70 60 51 — 187 133 105 86 73 64 267 191 149 124 105 89 148 111 38 — — — 206 155 119 97 81 — 294 221 170 138 116 100 409 310 236 192 162 138 89 83 — — — — 130 121 95 76 64 — 191 178 137 114 95 83 273 254 197 159 137 117 Œ 51 102 152 203 254 305 Notes: Œ Nozzle length is dimension L from end of standard control body to opening in tank having minimum diameter listed for each model.  Minimum diameter given is I.D. of float switch body. Ž Minimum diameter given is I.D. of 3" schedule 40 pipe.  Minimum diameter given is I.D. of 3" schedule 80 pipe.  Consult factory for maximum differential available for models T57, T64, T67, and T68 . 5 MODEL NUMBER Models available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). MODEL NUMBER, MATERIAL OF CONSTRUCTION AND TANK CONNECTION Model Set Points Code 1 T52 1 2 1 2 3 4 T63 1 1 4 T64 1 1 Material of Construction Description Cast Iron body, 300 Series SS trim, 400 Series SS sleeve Cast Iron body, 316 SS trim and sleeve Carbon Steel body, 300 series SS trim, 400 Series SS sleeve Carbon Steel body, 316 SS trim and sleeve 304 SS body, 300 Series SS trim and sleeve 316 SS body, trim and sleeve Cast Iron body, 300 Series SS trim, 400 Series SS sleeve 316 SS body, trim and sleeve Carbon Steel body, 300 Series SS trim, 400 Series SS sleeve Carbon Steel body, 300 Series SS trim, 400 Series SS sleeve H3 H4 H5 F2 G3 G4 G5 H3 4" 150 lb. RF Flange 4" 300 lb. RF Flange 4" 600 lb. RF Flange 3" NPT 3" 150 lb. RF Flange 3" 300 lb. RF Flange 3" 600 lb. RF Flange 4" 150 lb. RF Flange ANSI RF Flange Ratings 500 — 377 353 144 34 — 26 24 23 Tank Connection Code Description Pressure RatingŒ psig @ °F bar @ °C 100 450 750 900 1000 38 232 399 482 538 E3 4" Cast Iron Square Flange 3" NPT 3" 150 lb. RF Flange 3" 300 lb. RF Flange 3" 600 lb. RF Flange 4" 150 lb. RF Flange 4" 300 lb. RF Flange 4" 600 lb. RF Flange 21⁄2" NPT 250 150 n/a n/a n/a 17 10 n/a n/a n/a F2 G3 G4 G5 H3 H4 H5 E2 500 — 377 353 144 34 — 26 24 23 T62 1 ANSI RF Flange Ratings 250 150 n/a n/a n/a 17 10 n/a n/a n/a T67 2 1 ANSI RF Flange Ratings FLOAT AND FLOAT STEM LENGTH Float Stem Length and Specific Gravity Rating Inches mm Inches mm Inches mm Inches mm 8.00 203 12.00 305 18.00 457 26.00 660 Inches mm S.G. Code S.G. Code S.G. Code S.G. Code 2.50 64 0.80 0.80 0.90 0.90 A B C D 2.50 × 4.00 64 × 102 0.52 0.55 0.60 0.66 E F G H 0.55 0.55 0.60 0.60 3.00 Ž 76 Ž J K L M 0.50 0.50 0.55 0.55 3.50  89  N P Q R 0.65 0.70 0.70 3.00 × 5.00 Ž 76 × 127 Ž 0.65 S T V W Model T64 Only 3.50 89 0.40 — — — — — — N Float Size All Models Excluding T64 Pressure/Temperature Ratings 100 350 100 250 400 500 PSIG @ ° F 750 900 1000 282 271 268 81 78 77 201 194 191 322 310 306 377 353 335 Bar @ ° C 38 399 482 24 19 19 7 6 5 17 14 13 28 22 21 34 26 24 65 60 538 18 5 13 21 23 58 1200 936 876 794 83 Œ Compare with float rating and use lower value for selection.  Float cannot pass through 3" NPT opening. Ž To pass float, tank nozzle internal bore diameter must not be less than 3.06 (78).  3.50 (89) diameter and 3.00 x 5.00 (76 x 127) floats not available in models T52 and T63.  Process temperature based on +100° F (+38° C) ambient. ‘ Dual switches available only with tandem model T67. ’ CSA approval does not apply to Series HE switches. “ On condensing applications, temperature down-rated to +400° F. ” Pneumatic switches not available on models T64 or T67. (Select from Next Page) 6 ELECTRIC SWITCH MECHANISM AND ENCLOSURE Process  Temperature Set ‘ Contacts Range Points °F (°C) All models with Material of All models with Material of Construction Code 1, Construction Codes 2, 3 & except model T64 4, except model T64 TYPE 4X/7/9 Aluminum Enclosure ATEX ATEX ATEX Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Ex II 2 G EEx Ex II 2 G EEx Ex II 2 G EEx Groups C&D Group B Groups C&D Group B Groups C&D Group B d IIC T6 d IIC T6 d IIC T6 Model T64 only Switch Description Series B Snap Switch -40 to +250 (-40 to +121) SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT SPDT DPDT Series C Snap Switch -40 to +450 (-40 to +232) Series D DC Current -40 to +250 Snap Switch (-40 to +121) Series F -50 to +750 Hermetically Sealed (-46 to +399) Snap Switch Series HS Hermetically Sealed -50 to +550“ 5-amp Snap Switch (-46 to +288) with Wiring Leads Series HS Hermetically Sealed -50 to +550“ 5-amp Snap Switch (-46 to +288) with Terminal Block Series H1 Hermetically Sealed -50 to +750 1-amp Snap Switch (-46 to +399) with Wiring Leads Series R High Temperature Snap Switch -40 to +750 (-40 to +399) 1 2 1 2 1 2 1 2 1 1 1 2 1 2 1 BKP BLA BNP BOA CKP CLA CNP COA BKT BLJ BNT BOJ CKT CLJ CNT COJ N/A BAC BDC BBC BGC CAC CDC CBC CGC BKQ BNQ CKQ CNQ DKQ DNB FKQ FNQ HMC FKP FLA FNP FOA FKT FLJ FNT FOJ N/A FAC FDC FBC FGC BKS N/A BNS N/A CKS N/A CNS N/A DKS DNK FKS N/A FNS N/A HEK’ HET’ HM4 HM8 BA9 BB9 CA9 CB9 DA9 DF9 FA9 FB9 BKA BNA CKA CNA DKB DNB FKA FNA HMJ BKJ N/A BNJ N/A CKJ N/A CNJ N/A DKK DNK FKJ N/A FNJ N/A HMK BCC BFC CCC CFC DC9 DF9 FCC FFC N/A HMS HA9 HB9 HM3 HM7 HMT HM4 HM8 N/A 1 1 N/A 1 HMF HM3 HM7 HA9 HB9 SPDT 1 N/A HKC N/A HKJ HKK N/A SPDT DPDT SPDT DPDT SPDT DPDT 1 N/A 1 1 2 1 2 1 2 1 2 8KP 8LA 8NP 8OA 9KP 9LA 9NP 9OA 8KT 8LJ 8NT 8OJ 9KT 9LJ 9NT 9OJ 8AC 8DC 8BC 8GC 9AC 9DC 9BC 9GC RKB RNB 8KQ 8NQ 9KQ 9NQ RKK RNK 8KS N/A 8NS N/A 9KS N/A 9NS N/A RC9 RF9 8A9 8B9 9A9 9B9 RKB RNB 8KA 8NA 9KA 9NA RKK RNK 8KJ N/A 8NJ N/A 9KJ N/A 9NJ N/A RC9 RF9 8CC 8FC 9CC 9FC Series 8 -50 to +750 Hermetically Sealed (-46 to +399) Snap Switch Series 9 High Temperature -50 to +750 Hermetically Sealed (-46 to +399) Snap Switch Switch Description CS/ CS/ CS/ Process  Cast Iron Cast Iron Cast Iron Aluminum Aluminum Aluminum Temp. Range Contacts Set ‘ Points Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 Class I, Div 1 NEMA 4X NEMA 4X NEMA 4X °F (°C) Groups C&D Group B Groups C&D Group B Groups C&D Group B 1 R1M RKM RKW R1M RKM RKW SPDT Series R 2 N/A N/A -40 to +1000 High Temperature N/A (-40 to +538) 1 RDM RNM RNW RDM RNM RNW Snap Switch DPDT 2 N/A N/A 1 9AR 9KR 9KV 9AY 9KY 9KW 9AD 9KD 9KV Series 9 SPDT 2 9BD 9LD 9LV N/A N/A High Temperature -50 to +1000 Hermetically Sealed (-46 to +538) 1 9DR 9NR 9NV 9DY 9NY 9NW 9DD 9ND 9NV DPDT Snap Switch 2 9ED 9OD 9OV N/A N/A PNEUMATIC SWITCH MECHANISM AND ENCLOSURE ” Switch Description Series J Bleed Type Series K Non-Bleed Type Maximum Supply Pressure PSIG 100 60 100 40 Bar 7 4 7 3 Maximum Process Temperature °F 400 400 400 400 °C 204 204 204 204 Bleed Orifice Diameter Inches 0.63 0.94 — — mm 1.6 2.3 — — All Models with Material of Construction Code 1 NEMA 1 JDE JEE — KOG All Models w/Material of Construction Codes 2, 3 or 4 NEMA 1 JDE JEE KOE — 7 QUALITY The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. The Magnetrol quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available. ESP Expedite Ship Plan Several Liquid Level Switches are available for quick shipment, usually within one week after factory receipt of a complete purchase order, through the Expedite Ship Plan (ESP). To take advantage of ESP, match the color coded model number codes in the selection charts (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. WARRANTY All Magnetrol mechanical level and flow controls are warranted free of defects in materials or workmanship for five full years from the date of original factory shipment. If returned within the warranty period; and, upon factory inspection of the control, the cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com 145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306 Heikensstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317 Copyright © 2011 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Performance specifications are effective with date of issue and are subject to change without notice. Magnetrol and Magnetrol logotype are registered trademarks of Magnetrol International. CSA logotype is a registered trademark of Canadian Standards Association BULLETIN: 44-116.20 EFFECTIVE: May 2010 SUPERSEDES: June 2009
T52-1E2A-BKP 价格&库存

很抱歉,暂时无法提供与“T52-1E2A-BKP”相匹配的价格&库存,您可以联系我们找货

免费人工找货