    MAX15034 - Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applicati...

  • 数据手册
  • 价格&库存
MAX15034 数据手册
19-4218; Rev 1; 10/11 KIT ATION EVALU ILABLE AVA Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications General Description The MAX15034 two-phase, configurable single- or dualoutput buck controller has an input voltage range of 4.75V to 5.5V or 5V to 28V. A mode select input allows for a dual-output supply or connecting two phases together for a single-output, high-current supply. Each output channel of the MAX15034 drives n-channel MOSFETs and is capable of providing more than 25A of load current. The MAX15034 uses average currentmode control with a switching frequency up to 1MHz per phase where each phase is 180° out of phase with respect to the other. Out-of-phase operation results in significantly reduced input capacitor ripple current and output voltage ripple in dual-phase, single-output voltage applications. Each controller has its own high-performance current and voltage-error amplifier that can be compensated for optimum output filter L-C values and transient response. The MAX15034 offers two enable inputs with accurate turn-on thresholds to allow for output voltage sequencing of the two outputs. The device’s switching frequency can be programmed from 100kHz to 1MHz with an external resistor. The MAX15034 can be synchronized to an external clock. Each output voltage is adjustable from 0.61V to 5.5V. Additional features include thermal shutdown and hiccup-mode, short-circuit protection. Use the MAX15034 with adaptive voltage positioning for applications that require a fast transient response or accurate output voltage regulation. The MAX15034 is available in a thermally enhanced 28pin TSSOP package capable of dissipating 2.1W. The device is rated for operation over the -40°C to +125°C automotive temperature range. o 4.75V to 5.5V or 5V to 28V Input o Dual-Output Synchronous Buck Controller o Configurable for Two Separate Outputs (25A) or One Single Output (50A) o Average Current-Mode Control with Accurate Adjustable Current Limit o 180° Interleaved Operation Reduces Size of Input Filter Capacitors o Limits Reverse Current Sinking When Operated in Parallel Mode o Each Output is Adjustable from 0.61V to 5.5V o Independently Programmable Adaptive Voltage Positioning o Monotonic Startup into Prebiased Outputs o Independent Shutdown for Each Output o 100kHz to 1MHz per Phase Programmable Switching Frequency o Oscillator Frequency Synchronization from 200kHz to 2MHz o Digital Soft-Start on Outputs o Hiccup-Mode Overcurrent Protection o Overtemperature Shutdown o Thermally Enhanced 28-Pin TSSOP Package Capable of Dissipating 2.1W Features MAX15034 Applications High-End Computers/Workstations/Servers Graphics Cards Networking Systems Point-of-Load High-Current/High-Density Telecom DC-DC Regulators RAID Systems PART MAX15034AAUI+ MAX15034BAUI+ MAX15034BAUI/V+ Ordering Information TEMP RANGE -40°C to +125°C -40°C to +125°C -40°C to +125°C PIN-PACKAGE 28 TSSOP 28 TSSOP-EP* 28 TSSOP-EP* +Denotes a lead(Pb)-free/RoHS-compliant package. *EP = Exposed pad. /V Denotes an automotive qualified part. ________________________________________________________________ Maxim Integrated Products 1 For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com. Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 ABSOLUTE MAXIMUM RATINGS IN, LX_ to AGND.....................................................-0.3V to +30V BST_ to AGND........................................................-0.3V to +35V DH_ to LX_ ....................................-0.3V to (VBST_ - VLX_) + 0.3V DL_ to PGND ..............................................-0.3V to (VDD + 0.3V) BST_ to LX_ ..............................................................-0.3V to +6V VDD to PGND............................................................-0.3V to +6V AGND to PGND .....................................................-0.3V to +0.3V AVGLIMIT, REG, RT/CLKIN, CSP_, CSN_ to AGND ......................................................-0.3V to +6V All Other Pins to AGND ............................-0.3V to (VREG + 0.3V) REG Continuous Output Current (limited by power dissipation, no thermal or short-circuit protection).........................................................................67mA Continuous Power Dissipation (TA = +70°C) (Note 1) 28-Pin TSSOP (derate 14mW/°C above +70°C) ..........1117mW 28-Pin TSSOP-EP (derate 27mW/°C above +70°C)........2162mW Operating Temperature Range .........................-40°C to +125°C Maximum Junction Temperature .....................................+150°C Storage Temperature Range .............................-60°C to +150°C Lead Temperature (soldering, 10s) .................................+300°C Soldering Temperature (reflow) .......................................+260°C Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. PACKAGE THERMAL CHARACTERISTICS (Note 1) TSSOP Junction-to-Ambient Thermal Resistance (θJA)..................71.6°C/W Junction-to-Case Thermal Resistance (θJC)......................13°C/W TSSOP-EP Junction-to-Ambient Thermal Resistance (θJA)..................37°C/W Junction-to-Case Thermal Resistance (θJC)......................2°C/W Note 1: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a fourlayer board. For detailed information on package thermal considerations, refer to www.maxim-ic.com/thermal-tutorial. ELECTRICAL CHARACTERISTICS (VIN = VREG = VDD = VEN_ = +5V, TA = TJ = TMIN to TMAX, unless otherwise noted, circuit of Figure 6. Typical values are at TA = +25°C.) (Note 2) PARAMETER SYSTEM SPECIFICATIONS 5 Input Voltage Range Quiescent Supply Current REG Undervoltage Lockout Hysteresis REG Output Accuracy REG Dropout INTERNAL REFERENCE Internal Reference Voltage VEAN_ EAN_ connected to EAOUT_ (Note 3) TA = -40°C to +125°C 0.605 0.6125 0.620 V Clock cycles Steps VIN IIN UVLO VHYST VIN = 5.8V to 28V, ISOURCE = 0 to 65mA VIN < 5.8V, ISOURCE = 60mA 4.75 IN and REG shorted together for +5V operation fOSC = 500kHz, DH_ or DL_ = open VREG rising 4.0 4.75 7 4.15 200 5.10 5.30 0.5 28 5.50 17 4.5 V mA V mV V V SYMBOL CONDITIONS MIN TYP MAX UNITS STARTUP/INTERNAL REGULATOR OUTPUT (REG) Digital Ramp Period for Soft-Start Soft-Start Voltage Steps MOSFET DRIVERS p-Channel Output Driver Impedance RON_P 1024 64 1.35 3 Ω 2 _______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications ELECTRICAL CHARACTERISTICS (continued) (VIN = VREG = VDD = VEN_ = +5V, TA = TJ = TMIN to TMAX, unless otherwise noted, circuit of Figure 6. Typical values are at TA = +25°C.) (Note 2) PARAMETER n-Channel Output Driver Impedance Output Driver Source Current Output Driver Sink Current Nonoverlap Time (Dead Time) RT/CLKIN Output Voltage RT/CLKIN Current Sourcing Capability RT/CLKIN Logic-High Threshold RT/CLKIN Logic-Low Threshold RT/CLKIN High Pulse Width RT/CLKIN Synchronization Frequency Range CURRENT LIMIT Internal Average Current-Limit Threshold Reverse Average Current-Limit Threshold External Average Current-Limit Threshold Adjustment AVGLIMIT Ground Threshold Voltage Leakage Current at AVGLIMIT VCL_ VRCL_ VCL_ADJ VAVGLIMIT_GND IAVGLIMIT VAVGLIMIT = 3V VCSP_ - VCSN_ VCSP_ - VCSN_ Resistor-divider connected from REG to AVGLIMIT to AGND 20.4 -3.0 22.5 -1.53 VAVGLIMIT 0.6/36 550 100 24.75 -0.1 mV mV V mV nA SYMBOL RON_N IDH_, IDL_ IDH_, IDL_ tNO VRT/CLKIN IRT/CLKIN VRT/CLKIN_H VRT/CLKIN_L tRT/CLKIN fRT/CLKIN 200 30 2000 2.4 0.8 CDH_ or CDL_ = 5nF fSW = 1MHz nominal, RRT = 12.4kΩ -7.5 -10 1.225 0.5 CONDITIONS MIN TYP 0.45 2.5 5 +7.5 +10 MAX 1.35 UNITS Ω A A % V mA V V ns kHz MAX15034 DIGITAL FAULT INTEGRATION (DF_) Number of Switching Cycles to Shutdown in Current Limit Number of Switching Cycles to Recover from Shutdown CURRENT-SENSE AMPLIFIER CSP_ to CSN_ Input Resistance Common-Mode Range Input Offset Voltage Amplifier Gain RCS_ VCMR(CS) VOS(CS) AV(CS) VIN = VREG = 4.75V to 5.5V or VIN = 5V to 10V VIN = 7V to 28V -0.3 -0.3 100 36 3.8 +3.6 +5.5 kΩ V V µV V/V NSDF_ NRDF_ 32,768 524,288 Clock cycles Clock cycles _______________________________________________________________________________________ 3 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 ELECTRICAL CHARACTERISTICS (continued) (VIN = VREG = VDD = VEN_ = +5V, TA = TJ = TMIN to TMAX, unless otherwise noted, circuit of Figure 6. Typical values are at TA = +25°C.) (Note 2) PARAMETER -3dB Bandwidth CSP_ Input Bias Current SYMBOL f-3dB ICSA(IN) VCSP_ = 5.5V, sinking VCSP_ = 0V, sourcing 550 No load 50 70 3 VEAN_ = 2.0V With respect to VCM With respect to VCM 100 1 -0.234 CONDITIONS MIN TYP 4 120 30 MAX UNITS MHz µA CURRENT-ERROR AMPLIFIER (CEA_) Transconductance Open-Loop Gain Open-Loop Gain Unity-Gain Bandwidth EAN_ Input Bias Current Error-Amplifier Output Clamping High Voltage Error-Amplifier Output Clamping Low Voltage EN_ INPUTS EN_ Input High Voltage EN_ Hysteresis EN_ Input Leakage Current Startup Delay Time to OUT_ MODE INPUT MODE Logic-High Threshold MODE Logic-Low Threshold MODE Input Pulldown PREBIASED OUTPUT Peak Sink Current-Limit Threshold during Reference Soft-Start Digital Ramp Period for Stepping Peak Sink Current Limit after Reference Soft-Start THERMAL SHUTDOWN Thermal Shutdown Thermal Shutdown Hysteresis TSHDN THYST 160 10 °C VCSP_ - VCSN_ -2.1 mV VMODE_H VMODE_L IPULLDWN 5 2.4 0.8 V V µA IEN tSTART_DELAY From EN_ rising to VOUT_ rising -200 1 VENH EN rising 1.2 1.222 0.05 +200 1.245 V nA ms gm AVOL(CEA) AVOL(EA) fUGEA IBIAS(EA) VCLMP_HI (EA) VCLMP_LO (EA) µS dB dB MHz nA V V VOLTAGE-ERROR AMPLIFIER (EAOUT_) 448 Clock cycles Note 2: The device is 100% production tested at TA = TJ = +125°C. Limits at TA = -40°C and TA = +25°C are guaranteed by design. Note 3: The internal reference voltage accuracy is measured at the negative input of the error amplifiers (EAN_). Output voltage accuracy must include external resistor-divider tolerances. 4 _______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 Typical Operating Characteristics (Circuit of Figure 6, TA = +25°C, unless otherwise noted. VIN = 12V, VOUT1 = 0.8V, VOUT2 = 1.3V, fSW = 500kHz per phase.) SUPPLY CURRENT vs. TEMPERATURE AND FREQUENCY (VIN = 5V) MAX15034 toc01 MAX15034 toc02a OSCILLATOR FREQUENCY vs. RT 10,000 OSCILLATOR FREQUENCY (kHz) CDH_ = CDL_ = 0 16 14 SUPPLY CURRENT (mA) 12 10 8 6 4 2 10 0 100 200 300 400 500 600 700 800 900 1000 RT (kΩ) 0 SUPPLY CURRENT vs. TEMPERATURE AND FREQUENCY (VIN = 12V) CDH_ = CDL_ = 0 fSW = 1MHz 14 SUPPLY CURRENT (mA) 12 10 8 6 4 2 0 fSW = 125kHz fSW = 250kHz fSW = 500kHz MAX15034 toc02b CDH_ = CDL_ = 0 fSW = 1MHz fSW = 500kHz 16 1000 fSW = 250kHz fSW = 125kHz 100 -40 -25 -10 5 20 35 50 65 80 95 110 125 TEMPERATURE (°C) -40 -25 -10 5 20 35 50 65 80 95 110 125 TEMPERATURE (°C) SUPPLY CURRENT vs. TEMPERATURE AND FREQUENCY (VIN = 24V) MAX15034 toc02c SUPPLY CURRENT vs. OSCILLATOR FREQUENCY MAX15034 toc03 SUPPLY CURRENT vs. DRIVER LOAD CAPACITANCE 90 80 SUPPLY CURRENT (mA) 70 60 50 40 30 20 10 0 CLOAD = CDH_ = CDL_ MAX15034 toc04 16 14 SUPPLY CURRENT (mA) 12 10 8 6 4 2 0 14 CDH_ = CDL_ = 0 13 SUPPLY CURRENT (mA) 12 11 10 9 8 7 6 VIN = 5V VIN = 24V VIN = 12V 100 CDH_ = CDL_ = 0 fSW = 1MHz fSW = 500kHz fSW = 250kHz fSW = 125kHz -40 -25 -10 5 20 35 50 65 80 95 110 125 TEMPERATURE (°C) 200 400 600 800 1000 1200 1400 1600 1800 2000 FREQUENCY (kHz) 0 5 10 15 CLOAD (nF) 20 25 30 REG LOAD REGULATION MAX15034 toc05 REG LINE REGULATION MAX15034 toc06 OUTPUT LOAD-TRANSIENT RESPONSE MAX15034 toc07 5.10 VIN = 24V 5.10 5.08 5.06 VREG (V) 5.04 5.02 5.00 IREG = 60mA 4.98 IREG = 0 20A IOUT 10A/div 5.05 VREG (V) 5.00 VIN = 5.5V 4.95 VIN = 12V VOUT 100mV/div AC-COUPLED 4.90 0 10 20 30 40 50 60 70 80 90 100 IREG (mA) 4.96 5 7 9 11 13 15 17 19 21 23 2ms/div VIN (V) _______________________________________________________________________________________ 5 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 Typical Operating Characteristics (continued) (Circuit of Figure 6, TA = +25°C, unless otherwise noted. VIN = 12V, VOUT1 = 0.8V, VOUT2 = 1.3V, fSW = 500kHz per phase.) DRIVER RISE TIME vs. LOAD CAPACITANCE MAX15034 toc08 DRIVER FALL TIME vs. LOAD CAPACITANCE 35 DH_ 30 DL_ tFALL (ns) 25 DL_ 20 15 10 5 0 MAX15034 toc09 100 90 80 70 tRISE (ns) 60 50 40 30 20 10 0 0 2 4 6 DH_ 40 8 10 12 14 16 18 20 22 CLOAD (nF) 0 2 4 6 8 10 12 14 16 18 20 22 CLOAD (nF) HIGH-SIDE DRIVER RISE TIME (VIN = 12V, CLOAD = 10nF) HIGH-SIDE DRIVER FALL TIME (VIN = 12V, CLOAD = 10nF) MAX15034 toc10 MAX15034 toc11 DH_ 2V/div DH_ 2V/div 20ns/div 20ns/div LOW-SIDE DRIVER RISE TIME (VIN = 12V, CLOAD = 10nF) MAX15034 toc12 LOW-SIDE DRIVER FALL TIME (VIN = 12V, CLOAD = 10nF) MAX15034 toc13 DL_ 2V/div DL_ 2V/div 20ns/div 20ns/div 6 _______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications Typical Operating Characteristics (continued) (Circuit of Figure 6, TA = +25°C, unless otherwise noted. VIN = 12V, VOUT1 = 0.8V, VOUT2 = 1.3V, fSW = 500kHz per phase.) MAX15034 OUT1/OUT2 OUT-OF-PHASE WAVEFORMS (VOUT1 = 0.8V, VOUT2 = 1.3V) MAX15034 toc14 TURN-ON/TURN-OFF WAVEFORM MAX15034 toc15 LX1 10V/div OUT1 100mV/div VOUT1 1V/div EN1 5V/div VOUT2 1V/div EN2 5V/div 1ms/div LX2 10V/div OUT2 100mV/div 10µs/div SHORT-CIRCUIT CURRENT WAVEFORMS (VIN = 5V) MAX15034 toc16 AVERAGE CURRENT LIMIT vs. VAVGLIMIT MAX15034 toc17 75 AVERAGE CURRENT LIMIT (mV) IOUT1 10A/div 60 45 30 IOUT2 10A/div 15 0 200ms/div 0 0.5 1.0 1.5 2.0 VAVGLIMIT (V) 2.5 3.0 INTERNAL REFERENCE VOLTAGE vs. TEMPERATURE MAX15034 toc18 SWITCHING FREQUENCY vs. TEMPERATURE MAX15034 toc19 0.620 INTERNAL REFERENCE VOLTAGE (V) 550 SWITCHING FREQUENCY (kHz) 525 0.615 500 0.610 475 0.605 -40 -25 -10 5 20 35 50 65 80 95 110 125 TEMPERATURE (°C) 450 -40 -25 -10 5 20 35 50 65 80 95 110 125 TEMPERATURE (°C) _______________________________________________________________________________________ 7 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 Typical Operating Characteristics (continued) (Circuit of Figure 6, TA = +25°C, unless otherwise noted. VIN = 12V, VOUT1 = 0.8V, VOUT2 = 1.3V, fSW = 500kHz per phase.) INTERNAL AVERAGE CURRENT LIMIT vs. TEMPERATURE MAX15034 toc20 INTERNAL AVERAGE REVERSE CURRENT LIMIT vs. TEMPERATURE INTERNAL AVERAGE CURRENT LIMIT (mV) MAX15034 toc21 25 INTERNAL AVERAGE CURRENT LIMIT (mV) 0 -0.5 -1.0 -1.5 -2.0 -2.5 -3.0 24 23 22 21 20 -40 -25 -10 5 20 35 50 65 80 95 110 125 TEMPERATURE (°C) -40 -25 -10 5 20 35 50 65 80 95 110 125 TEMPERATURE (°C) SOFT-START WAVEFORM MAX15034 toc22 PREBIASED OUTPUT CONDITION MAX15034 toc23 EN2 5V/div VOUT2 500mV/div EN2 5V/div VOUT2 500mV/div VEAN2 200mV/div DH2 5V/div DL2 5V/div 0V EAOUT2 1V/div 400µs/div 400µs/div PEAK PULLUP AND PULLDOWN CURRENT OR DRIVER AT DH_ AND DL_ MAX15034 toc24 CLOAD = 10nF DH_ 500mV/div DL_ 500mV/div 200ns/div 8 _______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications Pin Description PIN 1 NAME CSN2 FUNCTION Current-Sense Differential Amplifier Negative Input for Output 2. Connect CSN2 to the negative terminal of the sense resistor. The differential voltage between CSP2 and CSN2 is internally amplified by the currentsense amplifier (AV(CS) = 36V/V). Current-Sense Differential Amplifier Positive Input for Output 2. Connect CSP2 to the positive terminal of the sense resistor. The differential voltage between CSP2 and CSN2 is internally amplified by the current-sense amplifier (AV(CS) = 36V/V). Voltage Error-Amplifier Output 2. Connect to an external gain-setting feedback resistor. The error-amplifier gain determines the output voltage load regulation for adaptive voltage positioning. This output also serves as the compensation network connection from EAOUT2 to EAN2. A resistive network results in a drooped output-voltage-regulation characteristic. An integrator configuration results in very tight output-voltage regulation (see the Adaptive Voltage Positioning section). Voltage Error-Amplifier Inverting Input for Output 2. Connect a resistive divider from VOUT2 to EAN2 to AGND to set the output voltage. A compensation network connects from EAOUT2 to EAN2. A resistive network results in a drooped output-voltage-regulation characteristic. An integrator configuration results in very tight output-voltage regulation (see the Adaptive Voltage Positioning section). Current-Error Amplifier Output 2. Compensate the current loop by connecting an R-C network from CLP2 to AGND. Average Current-Limit Programming. Connect a resistor-divider between REG, AVGLIMIT, and AGND to set the average current-limit value (see the Programming Average the Current Limit section). External Clock Input or Internal Frequency-Setting Connection. Connect a resistor from RT/CLKIN to AGND to set the switching frequency. Connect an external clock at RT/CLKIN for external frequency synchronization. Analog Ground Mode Function Input. MODE selects between a single-output dual phase or a dual-output buck regulator. When MODE is grounded, VEA1 and VEA2 connect to CEA1 and CEA2, respectively (see Figure 1) and the device operates as a two-output, out-of-phase buck regulator. When MODE is connected to REG (logic high), VEA2 is disconnected and VEA1 is routed to both CEA1 and CEA2. Current-Error Amplifier Output 1. Compensate the current loop by connecting an R-C network from CLP1 to AGND. Voltage Error-Amplifier Inverting Input for Output 1. Connect a resistive divider from VOUT1 to EAN1 to regulate the output voltage. A compensation network connects from EAOUT1 to EAN1. A resistive network results in a drooped output-voltage-regulation characteristic. An integrator configuration results in very tight output-voltage regulation (see the Adaptive Voltage Positioning section). Voltage Error-Amplifier Output 1. Connect to an external gain-setting feedback resistor. The error-amplifier gain determines the output-voltage-load regulation for adaptive voltage positioning. This output also serves as the compensation network connection from EAOUT1 to EAN1. A resistive network results in a drooped output-voltage-regulation characteristic. An integrator configuration results in very tight output-voltage regulation (see the Adaptive Voltage Positioning section). Current-Sense Differential Amplifier Positive Input for Output 1. Connect CSP1 to the positive terminal of the sense resistor. The differential voltage between CSP1 and CSN1 is internally amplified by the current-sense amplifier (AV(CS) = 36V/V). Current-Sense Differential Amplifier Negative Input for Output 1. Connect CSN1 to the negative terminal of the sense resistor. The differential voltage between CSP1 and CSN1 is internally amplified by the currentsense amplifier (AV(CS) = 36V/V). MAX15034 2 CSP2 3 EAOUT2 4 EAN2 5 6 CLP2 AVGLIMIT 7 8 RT/CLKIN AGND 9 MODE 10 CLP1 11 EAN1 12 EAOUT1 13 CSP1 14 CSN1 _______________________________________________________________________________________ 9 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 Pin Description (continued) PIN 15 16 17 18 19 20 NAME EN1 BST1 DH1 LX1 DL1 VDD FUNCTION Output 1 Enable. A logic-low shuts down channel 1’s MOSFET drivers. EN1 can be used for output sequencing. Boost Flying-Capacitor Connection. Reservoir capacitor connection for the high-side MOSFET driver supply. Connect a 0.47µF ceramic capacitor between BST1 and LX1. High-Side Gate Driver Output 1. DH1 drives the gate of the high-side MOSFET. External Inductor Connection and Source Connection for the High-Side MOSFET for Output 1. LX1 also serves as the return terminal for the high-side MOSFET driver. Low-Side Gate Driver Output 1. Gate driver output for the synchronous MOSFET. Supply Voltage for Low-Side Drivers. REG powers VDD. Connect a parallel combination of 0.1µF and 1µF ceramic capacitors from VDD to PGND and a 1Ω resistor from VDD to REG to filter out the high-peak currents of the driver from the internal circuitry. Internal 5V Regulator Output. REG is derived internally from IN and is used to power the internal bias circuitry. Bypass REG to AGND with a 4.7µF ceramic capacitor. Supply Voltage Connection. Connect IN to a 5V to 28V input supply. Power Ground. Source connection for the low-side MOSFET. Connect VDD’s bypass capacitor returns to PGND. Low-Side Gate Driver Output 2. Gate driver for the synchronous MOSFET. External Inductor Connection and Source Connection for the High-Side MOSFET for Output 2. Also serves as the return terminal for the high-side MOSFET driver. High-Side Gate Driver Output 2. DH2 drives the gate of the high-side MOSFET. Boost Flying-Capacitor Connection. Reservoir capacitor connection for the high-side MOSFET driver supply. Connect a 0.47µF ceramic capacitor between BST2 and LX2. Output 2 Enable. A logic-low shuts down channel 2’s MOSFET drivers. EN2 can be used for output sequencing. Exposed Pad. Connect exposed pad to ground plane (MAX15034BAUI only). 21 22 23 24 25 26 27 28 — REG IN PGND DL2 LX2 DH2 BST2 EN2 EP Detailed Description The MAX15034 switching power-supply controller can be configured two ways. With the MODE input high, this device operates as single-output, dual-phase, stepdown switching regulators where each output is 180° out of phase. With MODE connected low, the MAX15034 operates as a dual-output, step-down switching regulator. The average current-mode control topology of the MAX15034 offers high-noise immunity while having benefits similar to those of peak currentmode control. Average current-mode control has the intrinsic ability to accurately limit the average current sourced by the converter during a fault condition. When a fault condition occurs, the error-amplifier output voltage (EAOUT1 or EAOUT2) that connects to the positive input of the transconductance amplifier (CA1 or CA2) is clamped, thus limiting the output current. The MAX15034 has internal logic to ensure each output’s monotonic startup under prebias load conditions. This facilitates glitch-free output voltage power-up in the presence of another redundant/parallel voltage regulator. The MAX15034 contains all blocks necessary for two independently regulated average current-mode PWM regulators. This device has two voltage error amplifiers (VEA1 and VEA2), two current-error amplifiers (CEA1 and CEA2), two current-sensing amplifiers (CA1 and CA2), two PWM comparators (CPWM1 and CPWM2), and drivers for both low- and high-side power MOSFETs (see Figure 1). Each PWM section is also equipped with a pulse-by-pulse, current-limit protection and a fault integration block for hiccup protection. 10 ______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 CLP1 10 CA1 14 CSN1 EAOUT1 EAN1 12 11 VEA1 IN 22 VREG = 5V UVLO 2VP-P RAMP CEA1 CPWM1 17 DH1 CONTROL AND DRIVER LOGIC 1 18 LX1 20 VDD 19 DL1 0° THERMAL SHUTDOWN DF1 AND HICCUP LOGIC 16 BST1 13 CSP1 REG EN1 AVGLIMIT 21 FOR INTERNAL BIASING CEN1 1.225V 15 6 OSCILLATOR AND PHASE SPLITTER EXTERNAL FREQUENCY SYNC 7 RT/CLKIN VINTREF = 0.61V 1.225V CEN2 180° 27 BST2 26 DH2 EN2 28 2VP-P RAMP AGND 8 CONTROL AND DRIVER LOGIC 2 VDD 25 LX2 24 DL2 VEA2 EAN2 4 MUX CEA2 DF2 AND HICCUP LOGIC 2 CSP2 CA2 CLP2 5 1 CSN2 CPWM2 23 PGND EAOUT2 MODE 3 9 Figure 1. Block Diagram Two enable comparators (CEN1 and CEN2) are available to control and sequence the two PWM sections through the enable (EN1 or EN2) inputs. An oscillator, with an externally programmable frequency generates two clock pulse trains and two ramps for both PWM sections. The two clocks and the two ramps are 180° out of phase with each other. A linear regulator (REG) generates the 5V to supply the device. This regulator has the output-current capability necessary to provide for the MAX15034’s internal circuitry and the power for the external MOSFET’s gate drivers. Internal UVLO circuitry ensures that the MAX15034 starts up when VREG is at the correct voltage levels to guarantee safe operation of the IC and of the power MOSFETs. Finally, a thermal-shutdown feature protects the device during thermal faults and shuts down the MAX15034 when the die temperature exceeds +160°C. ______________________________________________________________________________________ 11 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 Dual-Output/Dual-Phase Select (MODE) The MAX15034 can operate as a dual-output, independently regulated buck converter, or as a dual-phase, single-output buck converter. The MODE input selects between the two operating modes. When MODE is grounded (logic-low), VEA1 and VEA2 connect to CEA1 and CEA2, respectively (see Figure 1), and the device operates as a two-output DC-DC converter. When MODE is connected to REG (logic-high), VEA2 is disconnected and VEA1 is routed to both CEA1 and CEA2 and the device works as a dual-phase, single-output buck regulator with each output 180° out of phase with respect to each other. Minimize the trace inductance from BST_ and VDD to the rectifier diodes, D1 and D2, and from BST_ and LX_ to the boost capacitors, C8 and C9 (see Figure 6). This is accomplished by using short, wide trace lengths. Undervoltage Lockout (UVLO)/ Power-On Reset (POR)/Soft-Start The MAX15034 includes an undervoltage lockout (UVLO) with hysteresis, and a power-on reset circuit for converter turn-on and monotonic rise of the output voltage. The UVLO threshold monitors VREG and is internally set between 4.0V and 4.5V with 200mV of hysteresis. Hysteresis eliminates chattering during startup. Most of the internal circuitry, including the oscillator, turns on when V REG reaches 4.5V. The MAX15034 draws up to 4mA (typ) of current before VREG reaches the UVLO threshold. The compensation network at the current-error amplifiers (CLP1 and CLP2) provides an inherent soft-start of the output voltage. It includes (R14 and C10) in parallel with C11 at CLP1 and (R15 and C12) in parallel with C13 at CLP2 (see Figure 6). The voltage at the currenterror amplifier output limits the maximum current available to charge the output capacitors. The capacitor at CLP_ in conjunction with the finite output-drive current of the current-error amplifier yields a finite rise time for the output current and thus, the output voltage. Supply Voltage Connections (VIN/VREG) The MAX15034 accepts a wide input voltage range at IN of 5V to 28V. An internal linear regulator steps down VIN to 5.1V (typ) and provides power to the MAX15034. The output of this regulator is available at REG. For VIN = 4.75V to 5.5V, connect IN and REG together externally. REG can supply up to 65mA for external loads. Bypass REG to AGND with a 4.7µF ceramic capacitor for high-frequency noise rejection and stable operation. REG supplies the current for the MAX15034’s internal circuitry and for the MOSFET gate drivers (when connected externally to VDD), and can source up to 65mA. Calculate the maximum bias current (I BIAS ) for the MAX15034: IBIAS = IIN + fSW × ( QGQ1 + QGQ2 + QGQ3 + QGQ4 ) where IIN is the quiescent supply current into IN (4mA, typ), Q GQ1 , Q GQ2 , Q GQ3 , Q GQ4 are the total gate charges of MOSFETs Q1 through Q4 at VGS = 5V (see Figure 6), and fSW is the switching frequency of each individual phase. Setting the Switching Frequency (fSW) An internal oscillator generates the 180o out-of-phase clock signals required for both PWM modulators. The oscillator also generates the 2VP-P voltage ramps necessary for the PWM comparators. The oscillator frequency can be set from 200kHz to 2MHz by an external resistor (RT) connected from RT/CLKIN to AGND (see Figure 6). The equation below shows the relationship between RT and the switching frequency: fOSC = 2.5 × 1010 Hz RRT Low-Side MOSFET Driver Supply (VDD) VDD is the power input for the low-side MOSFET drivers. Connect the regulator output REG externally to VDD through an R-C lowpass filter. Use a 1Ω resistor and a parallel combination of 1µF and 0.1µF ceramic capacitors to filter out the high peak currents of the MOSFET drivers from the sensitive internal circuitry. High-Side MOSFET Drive Supply (BST_) BST1 and BST2 supply the power for the high-side MOSFET drivers for output 1 and output 2, respectively. Connect BST1 and BST2 to V DD through rectifier diodes D1 and D2 (see Figure 6). Connect a 0.1µF ceramic capacitor between BST_ and LX_. where RRT is in ohms and the per-phase switching frequency is fSW = fOSC/2. Use RT/CLKIN as a clock input to synchronize the MAX15034 to an external frequency (f RT/CLKIN ). Applying an external clock to RT/CLKIN allows each PWM section to work at a frequency equal to fRT/CLKIN/2. An internal comparator with a 1.6V threshold detects fRT/CLKIN. If fRT/CLKIN is present, internal logic switches from the internal oscillator clock, to the clock present at RT/CLKIN. 12 ______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications Hiccup Fault Protection The MAX15034 includes overload fault protection circuitry that prevents damage to the power MOSFETs. The fault protection consists of two digital fault integration blocks that enable hiccuping under overcurrent conditions. This circuit works as follows: for every clock cycle the currentlimit threshold is exceeded, the fault integration counter increments by one count. Thus, if the current-limit condition persists, the counter reaches its shutdown threshold in 32,768 counts and shuts down the external MOSFETs. When the MAX15034 shuts down due to a fault, the counter begins to count down (since the current-limit condition has ended), once every 16 clock cycles. Thus, the device counts down for 524,288 clock cycles. At this point, switching resumes. This produces an effective duty cycle of 6.25% power-up and 93.75% power-down under fault conditions. With a switching frequency set to 250kHz, power-up and power-down times are approximately 131ms and 2.09s, respectively. current, while the outer voltage loop controls the output voltage. The inner current loop absorbs the inductor pole, reducing the order of the outer voltage loop to that of a single-pole system. Figure 2 is the block diagram of OUT1’s control loop. The current loop consists of a current-sense resistor, RSENSE, a current-sense amplifier (CA1), a currenterror amplifier (CEA1), an oscillator providing the carrier ramp, and a PWM comparator (CPWM1). The precision current-sense amplifier (CA1) amplifies the sense voltage across RSENSE by a factor of 36. The inverting input to CEA1 senses the output of CA1. The output of CEA1 is the difference between the voltageerror amplifier output (EAOUT1) and the gained-up voltage from CA1. The RC compensation network connected to CLP1 provides external frequency compensation for the respective CEA1 (see the Compensation section). The start of every clock cycle enables the high-side driver and initiates a PWM oncycle. Comparator CPWM1 compares the output voltage from CEA1 against a 0 to 2V ramp from the oscillator. The PWM on-cycle terminates when the ramp voltage exceeds the error voltage from the current-error amplifier (CEA1). MAX15034 Control Loop The MAX15034 uses an average current-mode control topology to regulate the output voltage. The control loop consists of an inner current loop and an outer voltage loop. The inner current loop controls the output CSN1 CA 1 CSP1 RCF CCF CLP1 CCFF VIN RF CEA1 CPWM1 DRIVE IL RSENSE VOUT1 VEA1 2VP-P R1 COUT LOAD R2 VREF = 0.61V Figure 2. Current and Voltage Loops ______________________________________________________________________________________ 13 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 The outer voltage control loop consists of the voltageerror amplifier (VEA1). The noninverting input (EAN1) is externally connected to the midpoint of a resistive voltage-divider from OUT1 to EAN1 to AGND. The voltage loop gain is set by using an external resistor from the output of this amplifier (EAOUT1) to its inverting input (EAN1). The noninverting input of (VEA1) is connected to the 0.61V internal reference. The voltage at full load is given by: ⎛ R⎞ VOUT(FL) = 0.6125 × ⎜ 1 + 1 ⎟ − ∆VOUT ⎝ R2 ⎠ where ∆ V OUT is the voltage-positioning window described in the Adaptive Voltage Positioning section. Current-Error Amplifier The MAX15034 features two dedicated transconductance current-error amplifiers CEA1 and CEA2 with a typical gm of 550µS and 320µA output sink and source capability. The current-error amplifier outputs (CLP1 and CLP2) serve as the inverting input to the PWM comparators. CLP1 and CLP2 are externally accessible to provide frequency compensation for the inner current loops (see CCFF, CCF, and RCF in Figure 2). Compensate the current-error amplifier so that the inductor current down slope, which becomes the up slope at the inverting input of the PWM comparator, is less than the slope of the internally generated voltage ramp (see the Compensation section). Adaptive Voltage Positioning Powering new-generation ICs requires new techniques to reduce cost, size, and power dissipation. Voltage positioning (Figure 5) reduces the total number of output capacitors to meet a given transient response requirement. Setting the no-load output voltage slightly higher than the output voltage during nominally loaded conditions allows a larger downward voltage excursion when the output current suddenly increases. Regulating at a lower output voltage under a heavy load allows a larger upward-voltage excursion when the output current suddenly decreases. A larger allowed voltage-step excursion reduces the required number of output capacitors and/or allows the use of higher ESR capacitors. The MAX15034 internal 0.6125V reference provides a tolerance of ±1.25%. Using 0.1% resistors for R1 and R2 allows a 4% variation from the nominal output voltage. This available voltage range allows the reduction of the total number of output capacitors to meet a given transient response requirement resulting in a voltagepositioning window as shown in Figure 5. From the allowable voltage-positioning window calculate the value of RF from the equation below. I × RSENSE × 36 × R1 RF = OUT ∆VOUT where ∆VOUT is the allowable voltage-positioning window, RSENSE is the sense resistor, 36 is the currentsense amplifier gain, and R1 is as shown in Figure 4. PWM Comparator and R-S Flip-Flop The PWM comparator (CPWM1 or CPWM2) sets the duty cycle for each cycle by comparing the currenterror amplifier output to a 2VP-P ramp. At the start of each clock cycle an R-S flip-flop resets and the highside drivers (DH1 and DH2) turn on. The comparator sets the flip-flop as soon as the ramp voltage exceeds the current-error amplifier output voltage, thus terminating the on-cycle. Voltage-Error Amplifier The voltage-error amplifier (VEA_) sets the gain of the voltage control loop. Its output clamps to 1.14V and -0.234V relative to VCM = 0.61V. Set the MAX15034 output voltage by connecting a voltage-divider from the output to EAN_ to GND (see Figure 4). At no load, the output of the voltage error amplifier is zero. Use the equation below to calculate the no load voltage: ⎛ R⎞ VOUT(NL) = 0.6125 × ⎜ 1 + 1 ⎟ ⎝ R2 ⎠ 14 ______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 VDD CLP_ CSP_ CSN_ GMIN RAMP 2 x fSW (V/S) LX_ CLK 1.225V EN_ PGND R Q DL_ AV = 36V/V gm = 500µS PWM COMPARATOR S Q BST_ DH_ Figure 3. Current Comparator and MOSFET Driver Logic VOUT VOLTAGE-POSITIONING WINDOW VCNTR + ∆VOUT/2 RF R1 COUT LOAD R2 VREF = 0.61V EAN_ EAOUT_ VCNTR VCNTR - ∆VOUT/2 NO LOAD 1/2 LOAD LOAD (A) FULL LOAD Figure 4. Voltage Error Amplifier Figure 5. Defining the Voltage-Positioning Window MOSFET Gate Drivers (DH_, DL_) The high-side drivers (DH1 and DH2) and low-side drivers (DL1 and DL2) drive the gates of external n-channel MOSFETs. The high-peak sink and source current capability of these drivers provides ample drive for the fast rise and fall times of the switching MOSFETs. Faster rise and fall times result in reduced switching losses. For lowoutput, voltage-regulating applications where the duty cycle is less than 50%, choose high-side MOSFETs (Q2 and Q4, Figure 6) with a moderate RDS(ON) and a very low gate charge. Choose low-side MOSFETs (Q1 and Q3, Figure 6) with very low RDS(ON) and moderate gate charge. The driver block also includes a logic circuit that provides an adaptive nonoverlap time (30ns typ) to prevent shoot-through currents during transition. Figure 7 shows the dual-phase, single-output buck regulator. 15 ______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 VIN VDD D1 (100mA, 30V) C2 1µ F C8 0.1µF R1 2mΩ L1 0.5µH Q1 IRF7832 DL1 22Ω BST1 Q2 IRF7821 DH1 LX1 IN REG C5 10µF R3 1Ω D2 (100mA, 30V) C3 0.1µF C4 4.7µF 22Ω BST2 Q4 IRF7821 DH2 LX2 Q3 IRF7832 C9 0.1µF L2 0.8µH R2 2mΩ 0.8V/10A 1.3V/10A MAX15034 DL2 C6 680µF C7 680µF R4 1.74kΩ PGND CSP1 CSN1 EAN1 CSP2 CSN2 EAN2 EAOUT2 MODE R9 60.4kΩ R6 5.11kΩ R5 4.64kΩ EAOUT1 R8 29.4kΩ VREG R16 100kΩ EN1 C14 0.1µF EN2 C15 0.1µF PGND RT/CLKIN VREG AVGLIMIT R7 4.75kΩ R14 1kΩ CLP1 C11 120pF R15 1kΩ CLP2 C10 15nF R17 100kΩ C12 15nF AGND C13 120pF RT 24.9kΩ EXTERNAL FREQUENCY SYNC R18 19.6kΩ R19 10kΩ Figure 6. Dual-Output Buck Regulator 16 ______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 VIN VDD D1 (100mA, 30V) C2 1µ F C8 0.1µF R1 2mΩ L1 0.8µH Q1 IRF7832 22Ω BST1 Q2 IRF7821 DH1 LX1 IN REG C5 10µF R3 1Ω D2 (100mA, 30V) C3 0.1µF C4 4.7µF 22Ω BST2 Q4 IRF7821 DH2 LX2 1.3V/20A C9 0.1µF L2 0.8µH MAX15034 C6 680µF DL1 DL2 Q3 IRF7832 R2 2mΩ R4 5.11kΩ PGND CSP1 CSN1 EAN1 EAOUT1 R8 60.4kΩ VREG R16 100kΩ EN1 C14 0.1µF EN2 C15 0.1µF PGND CLP2 CLP1 C11 120pF R15 1kΩ C12 15nF CSP2 CSN2 EAN2 EAOUT2 MODE TO REG R5 4.75kΩ R14 1kΩ C10 15nF R17 100kΩ C13 120pF AVGLIMIT AGND RT/CLKIN RT 24.9kΩ EXTERNAL FREQUENCY SYNC Figure 7. Dual-Phase, Single-Output Buck Regulator ______________________________________________________________________________________ 17 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 Design Procedures Inductor Selection The switching frequency per phase, peak-to-peak ripple current in each phase, and allowable voltage ripple at the output, determine the inductance value. Selecting higher switching frequencies reduces the inductance requirement, but at the cost of lower efficiency due to the charge/discharge cycle of the gate and drain capacitances in the switching MOSFETs. The situation worsens at higher input voltages, since capacitive switching losses are proportional to the square of the input voltage. Lower switching frequencies on the other hand increase the peak-to-peak inductor ripple current (∆IL), and therefore, increase the MOSFET conduction losses (see the Power MOSFET Selection section for a detailed description of MOSFET power loss). When using higher inductor ripple current, the ripple cancellation in the multiphase topology, reduces the input and output capacitor RMS ripple current. Use the following equation to determine the minimum inductance value: L= VOUT (VIN(MAX) − VOUT ) VIN × fSW × ∆IL where 24.75mV is the maximum average current-limit threshold for the current-sense amplifier and RSENSE is the sense resistor. Power MOSFET Selection When choosing the MOSFETs, consider the total gate charge, R DS(ON) , power dissipation, the maximum drain-to-source voltage, and package thermal impedance. The product of the MOSFET gate charge and onresistance is a figure of merit, with a lower number signifying better performance. Choose MOSFETs optimized for high-frequency switching applications. The average gate-drive current from the MAX15034’s output is proportional to the total capacitance it drives at DH1, DH2, DL1, and DL2. The power dissipated in the MAX15034 is proportional to the input voltage and the average drive current. See the S upply Voltage Connections (VIN/VREG) and the Low-Side MOSFET Drives Supply (VDD) sections to determine the maximum total gate charge allowed from all driver outputs together. The losses may be broken into four categories: conduction loss, gate drive loss, switching loss, and output loss. The following simplified power loss equation is true for both MOSFETs in the synchronous buck-converter: PLOSS = PCONDUCTION + PGATEDRIVE + PSWITCH + POUTPUT For the low-side MOSFET, the PSWITCH term becomes virtually zero because the body diode of the MOSFET is conducting before the MOSFET is turned on. Tables 1 and 2 describe the different losses and shows an approximation of the losses during that period. Choose ∆IL to be equal to approximately 30% of the output current per channel. Since ∆IL affects the output-ripple voltage, the inductance value may need minor adjustment after choosing the output capacitors for fullrated efficiency. Choose inductors from the standard high-current, surface-mount inductor series available from various manufacturers. Particular applications may require custom-made inductors. Use high-frequency core material for custom inductors. High ∆IL causes large peak-to-peak flux excursion increasing the core losses at higher frequencies. The high-frequency operation coupled with high ∆IL, reduces the required minimum inductance and even makes the use of planar inductors possible. The advantages of using planar magnetics include low-profile design, excellent current sharing between phases due to the tight control of parasitics, and low cost. For example, the minimum inductance at VIN = 12V, VOUT = 0.8V, ∆IL = 3A, and fSW = 500kHz is 0.5µH. The average current-mode control feature of the MAX15034 limits the maximum inductor current, which prevents the inductor from saturating. Choose an inductor with a saturating current greater than the worst-case peak inductor current: IL _ PEAK = 24.75 × 10 −3 ∆IL + RSENSE 2 Input Capacitance The discontinuous input-current waveform of the buck converter causes large ripple currents in the input capacitor. The switching frequency, peak inductor current, and the allowable peak-to-peak voltage ripple reflected back to the source, dictate the capacitance requirement. Increasing the number of phases increases the effective switching frequency and lowers the peak-to-average current ratio, yielding lower input capacitance requirement. It can be shown that the worst-case RMS current occurs when only one controller section is operating. The controller section with the highest output power needs to be used in determining the maximum input RMS ripple current requirement. Increasing the output current drawn from the other outof-phase controller section results in reducing the input 18 ______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 Table 1. High-Side MOSFET Losses LOSS DESCRIPTION SEGMENT LOSS Conduction Loss Losses associated with MOSFET on-time and on-resistance. IRMS is a function of load current and duty cycle. PCONDUCTION = IRMS 2 × RDS(ON) where IRMS ≈ VOUT × ILOAD VIN Gate Drive Loss Losses associated with charging and discharging the gate capacitance of the MOSFET every cycle. Use the MOSFET’s (QG) specification. Losses during the drain voltage and drain current transitions for every switching cycle. Losses occur only during the QGS2 and QGD time period and not during the initial QGS1 period. The initial QGS1 period is the rise in the gate voltage from zero to VTH. RDH_ is the highside MOSFET driver’s on-resistance and RGATE is the internal gate resistance of the high-side MOSFET (QGD and QGS2 are found in the MOSFET data sheet). Losses associated with QOSS of the MOSFET occur every cycle when the high-side MOSFET turns on. The losses are caused by both MOSFETs, but are dissipated in the high-side MOSFET. PGATEDRIVE = VDD × (QG − QGD ) × fSW PSWITCH = VIN × ILOAD × fSW × (QGS2 + QGD ) IGATE Switching Loss where IGATE = VDD 2 × (RDH _ + RGATE ) Output Loss POUTPUT = QOSS(HS) + QOSS(LS) 2 × VIN × fSW ripple current. A low-ESR input capacitor that can handle the maximum input RMS ripple current of one channel must be used. The maximum RMS capacitor ripple current is given by: ICIN(RMS) ≈ IMAX VOUT (VIN − VOUT ) VIN step loads determine the capacitance and the ESR requirements for the output capacitors. The output ripple can be approximated as the inductor current ripple multiplied by the output capacitor’s ESR (RESR_OUT). The peak-to-peak inductor current ripple is given by: V (1 − D) ∆IL = OUT L × fSW During a load step, the allowable deviation of the output voltage during the fast transient load dictates the output capacitance and ESR. The output capacitors supply the load step until the controller responds with a greater duty cycle. The response time (tRESPONSE) depends on the closed-loop bandwidth of the regulator. The resistive drop across the capacitor’s ESR and capacitor discharge causes a voltage drop during a load step. Use a combination of SP polymer and ceramic capacitors for better transient load and ripple/noise performance. where IMAX is the full load current of the regulator. VOUT is the output voltage of the same regulator and CIN is C5 in Figure 6. The ESR of the input capacitors wastes power from the input and heats up the capacitor. Reducing the ESR is important to maintain a high overall efficiency and in reducing the heating of the capacitors. Output Capacitors The worst-case peak-to-peak inductor ripple current, the allowable peak-to-peak output ripple voltage, and the maximum deviation of the output voltage during ______________________________________________________________________________________ 19 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 Table 2. Low-Side MOSFET Losses LOSS DESCRIPTION SEGMENT LOSSES Conduction Loss Losses associated with MOSFET on-time, IRMS is a function of load current and duty cycle. PCONDUCTION = IRMS 2 × RDS(ON) where IRMS ≈ VIN − VOUT × ILOAD VIN Gate Drive Loss Losses associated with charging and discharging the gate of the MOSFET every cycle. There is no QGD charging involved in this MOSFET due to the zero-voltage turn-on. The charge involved is (QG - QGD). PGATEDRIVE = VDD × (QG − QGD ) × fSW Note: The gate drive losses are distributed between the drivers and the MOSFETs in the ratio of the gate driver’s resistance and the MOSFET’s internal gate resistance. Keep the maximum output-voltage deviation less than or equal to the adaptive voltage-positioning window (∆VOUT). During a load step, assume a 50% contribution each from the output capacitance discharge and the voltage drop across the ESR (∆VOUT = ∆VESR_OUT + ∆VQ_OUT). Use the following equations to calculate the required ESR and capacitance value: RESR _ OUT = COUT = ∆VESR _ OUT ILOAD _ STEP ∆VQ _ OUT The minimum average voltage, at which the voltage across the current-sense resistor is clamped, is either internally set to 20.4mV or is controlled by the voltage at AVGLIMIT. The AVGLIMIT ground threshold of 550mV (typ) is the threshold above which the control of the average current-limit voltage is transferred from the internal 20.4mV (min) reference to the externally set VAVGLIMIT. For using the internal average current-limit value, short AVGLIMIT to AGND. The minimum (internally set) average current limit is set at: ILIMIT(MIN) = 20.4mV RSENSE ILOAD _ STEP × tRESPONSE where I LOAD_STEP is the step in load current and t RESPONSE is the response time of the controller. Controller response time depends on the control-loop bandwidth. COUT is C6 and C7 in Figure 6. For example, the current-sense resistor: RSENSE = 20.4mV = 2.04mΩ 10A Current Limit The MAX15034 incorporates two forward current-limit protection mechanisms, average current limit and hiccup fault current limit, which accurately limit the output current per phase. The average current-mode control technique of the MAX15034 accurately limits the maximum average output current per phase. The MAX15034 senses the voltage across either a sense resistor or can implement lossless inductor sense, sensing the voltage across the parasitic resistance of the inductor (DCR). Use either mechanism to limit the maximum inductor current. for a maximum output current limit of 10A. A standard value is 2mΩ. Also, adjust the value of the currentsense resistor to compensate for parasitics associated with the PCB. Select a noninductive resistor with an appropriate wattage rating. The implementation is shown in Figure 8. When sensing directly across the inductor, connect an RC circuit directly across the shunt or inductor (see Figure 9). 20 ______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 LOUT LX_ RSENSE VOUT MAX15034 CSP_ CSN_ Figure 8. Noninductive Resistive Sense INDUCTOR L LX_ C1 DCR VOUT R1 MAX15034 CSP_ C2* CSN_ *OPTIONAL. R2* C3* Figure 9. Lossless Inductor Sense Set the RC time constant to be 1.1 to 1.2 times the inductor time constant (L/DCR). Select C1 to be in the 0.1µF to 0.47µF range, and then calculate R1 from: R1[kΩ] = 1.2 × L[µH] DCR[mΩ] × C1[µF] parallel with R2 to aid in short-circuit recovery. Set C3 equal to C1. Finally, it may be helpful to add a 100pF (C2) capacitor immediately across the CSP_ and CSN_ inputs to minimize high-frequency noise pick-up at the IC in some applications. For current-sense resistors that have a noticeable inductance component, use lossless inductor sense implementation (and design procedure). See Figure 10. Table 3 highlights the tradeoffs of each current-sense method. In some applications, it may be useful to add a resistor (R2 in Figure 9) in series with the CSN_ connection to minimize input offset error. Set R2 equal to R1. It may also prove useful to add capacitor C3 (Figure 9) in Table 3. Current-Sense Configurations METHOD Output Current-Sense Resistor Equivalent Inductor DC Resistance CURRENT-SENSE ACCURACY High Low INDUCTOR-SATURATION PROTECTION Allowed (highest accuracy) Allowed CURRENT-SENSE POWER LOSS (EFFICIENCY) RSENSE x IOUT2 No additional loss ______________________________________________________________________________________ 21 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 SENSE RESISTOR (INDUCTIVE) LOUT LX_ C1 ESL RSENSE VOUT R1 MAX15034 CSP_ C2 CSN_ R2 C3 Figure 10. Inductive Sense Resistor The MAX15034 provides precision average current-limit programmability while using standard sense resistors or shunts. Use the equation below to determine the appropriate VAVGLIMIT external reference voltage at AVGLIMIT: VAVGLIMIT = 56 × RSENSE [mΩ] × ILOAD(MAX) [A] + 612.5mV Programming the Average Current Limit The MAX15034 average current-limit reference voltage is set by connecting a resistor-divider network from REG to AGND, the center node is connected to AVGLIMIT. The resistive divider’s upper resistor, R1, is connected between REG and the AVGLIMIT. The resistive divider’s lower resistor, R2, is connected between the AVGLIMIT and AGND. The resistor-divider values are determined by first, choosing R2. To minimize reference noise select R2 such that (R1 + R2) < 100kΩ; a typical value is 10kΩ. Next, determine R1 from: ⎛ VREG ⎞ R1 = R2 × ⎜ − 1⎟ ⎝ VAVGLIMIT ⎠ ⎛ ⎞ 5V − 1⎟ = 10kΩ × ⎜ ⎝ VAVGLIMT(MAX) [V] ⎠ From the example above, assuming VAVGLIMIT = 1.91V: ⎛ 5V ⎞ R1 = 10kΩ × ⎜ − 1 = 16.18kΩ ⎝ 1.91V ⎟ ⎠ A standard value for R1 is 16.2kΩ. Connect AVGLIMIT to AGND for default current limit ⎛ 20.4mV ⎞ ⎜R ⎟. ⎝ ⎠ SENSE ( ) For example, assuming the desired average current limit is 18A, and RSENSE = 2mΩ. VAVGLIMIT = ( 2mΩ × 36 × 18 A ) + 612.5mV = 1910mV = 1.91V where RSENSE is determined from maximum load current, wattage rating, and circuit parasitics (see above) and ILOAD(MAX) from circuit requirements. VAVGLIMIT is the average current-limit reference voltage selected for a desired ILOAD(MAX) and is set by a resistive voltagedivider from REG to AGND. See the Programming the Average Current Limit section. The second current-protection circuit is the hiccup fault protection as explained in the Hiccup Fault Protection section. The average current during a short at the output is given by: IAVG(SHORT) = 0.0625 × ILOAD(MAX) 22 ______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications Reverse Current Limit The MAX15034 limits the reverse current when the output capacitor voltage is higher than the preset output voltage. Calculate the maximum reverse current limit based on V CLMP_LO and the current-sense resistor RSENSE. IREVERSE = 1.55 × 10−3 RSENSE 1) The average current tracks the programmed current with a high degree of accuracy. 2) Slope compensation is not required, but there is a limit to the loop gain at the switching frequency to achieve stability. 3) Noise immunity is excellent. 4) The average current-mode method can be used to sense and control the current in any circuit branch. For stability of the current loop, the amplified inductorcurrent downslope at the negative input of the PWM comparator (CPWM1 and CPWM2) must not exceed the ramp slope at the comparator’s positive input. This puts an upper limit on the current-error amplifier gain at the switching frequency. The inductor current downslope is given by VOUT/L where L is the value of the inductor (L1 and L2 in Figure 6) and VOUT is the output voltage. The amplified inductor current downslope at the negative input of the PWM comparator is given by: ∆VL VOUT = × RSENSE × 36 × gm × RCF ∆t L where RSENSE is the current-sense resistor (R1 and R2 in Figure 6) and gM x RCF is the gain of the current-error amplifier (CEA_) at the switching frequency. The slope of the ramp at the positive input of the PWM comparator is 2V x fSW. Use the following equation to calculate the maximum value of RCF (R14 or R15 in Figure 6). RCF ≤ 2 × fSW × L VOUT × RSENSE × 36 × gm (1) MAX15034 Output-Voltage Setting The output voltage is set by the combination of resistors R1, R2, and R F as described in the V oltage-Error Amplifier section. First select a value for resistor R2. Then calculate the value of R1 from the following equation: R1 = (VOUT(NL) − 0.6125) 0.6125 × R2 where VOUT(NL) is the voltage at no load. Then find the value of RF from the following equation: I × RSENSE × 36 × R1 RF = OUT ∆VOUT where ∆VOUT is the allowable drop in voltage from no load to full load. RF is R8 and R9, R1 is R4 and R6, R2 is R5 and R7 in Figure 6. Compensation The MAX15034 uses an average current-mode control scheme to regulate the output voltage (see Figure 2). The main control loop consists of an inner current loop and an outer voltage loop. The voltage error amplifier (VEA1 and VEA2) provides the controlling voltage for the current loop in each phase. The output inductor is hidden inside the inner current loop. This simplifies the design of the outer voltage control loop and also improves the power-supply dynamics. The objective of the inner current loop is to control the average inductor current. The gain-bandwidth characteristic of the current loop can be tailored for optimum performance by the compensation network at the output of the currenterror amplifier (CEA1 or CEA2). Compared with peak current-mode control, the current-loop gain crossover frequency, fC, can be made approximately the same, but the gain at low frequencies is much higher. This results in the following advantages over peak currentmode control. The highest crossover frequency fCMAX is given by: f × VIN fCMAX = SW 2π × VOUT or alternatively: f × 2π × VOUT fSW = CMAX VIN Equation (1) can now be rewritten as: RCF = π × fC × L VIN × RS × 9 × gm (2) ______________________________________________________________________________________ 23 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 In practical applications, pick the crossover frequency (fC) in the range of: fSW f < fC < SW 10 2 First calculate RCF in equation 2 above. Calculate CCF so that: 10 CCF = 2 × π × fC × RCF where CCF is C10 and C12 in Figure 6. Calculate CCFF so that: CCFF = 1 2 × π × fC × 10 × RCF especially true for dual-phase converters where one channel can affect the other. Use the following guidelines for PCB layout: 1) Place the VDD, REG, and the BST1 and BST2 bypass capacitors close to the MAX15034. 2) Minimize all high-current switching loops. 3) Keep the power traces and load connections short. This practice is essential for high efficiency. Use thick copper PCBs (2oz or higher) to enhance efficiency and minimize trace inductance and resistance. 4) Run the current-sense lines CSP_ and CSN_ very close to each other to minimize loop areas. Do not cross these critical signal lines through power circuitry. Sense the current right at the pads of the current-sense resistors. 5) Place the bank of output capacitors close to the load. 6) Isolate the power components on the top side from the analog components on the bottom side with a ground plane in between. 7) Provide enough copper area around the switching MOSFETs, inductors, and sense resistors to aid in thermal dissipation and reducing resistance. 8) Distribute the power components evenly across the top side for proper heat dissipation. 9) Keep AGND and PGND isolated and connect them at one single point close to the IC. Do not connect them together anywhere else. 10) Place all input bypass capacitors for each input as close to each other as is practical. where CCFF is C11 and C13 in Figure 6. Applications Information Independent Turn-On and Turn-Off The MAX15034 can be used to regulate two outputs from one controller. Each of the two outputs can be turned on and off independently of one another by controlling the enable input of each phase (EN1 and EN2). A logic-low on each enable pin shuts down the MOSFET drivers for that phase. When the voltage on the enable pin exceeds 1.2V, the drivers are turned on and the output can come up to regulation. This method of turning on the outputs allows the MAX15034 to be used for power sequencing. PCB Layout Guidelines Careful PCB layout is critical to achieve low losses, low output noise, and clean and stable operation. This is 24 ______________________________________________________________________________________ Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications Pin Configuration PROCESS: BiCMOS TOP VIEW CSN2 1 CSP2 2 EAOUT2 3 EAN2 4 CLP2 5 AVGLIMIT 6 RT/CLKIN 7 AGND 8 MODE 9 CLP1 10 EAN1 11 EAOUT1 12 CSP1 13 CSN1 14 *EXPOSED PAD Chip Information MAX15034 + 28 EN2 27 BST2 26 DH2 25 LX2 24 DL2 Package Information For the latest package outline information and land patterns (footprints), go to www.maxim-ic.com/packages. Note that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. PACKAGE TYPE 28 TSSOP 28 TSSOP-EP PACKAGE CODE U28+2 U28E+4 OUTLINE NO. 21-0066 21-0108 LAND PATTERN NO. 90-0171 90-0146 MAX15034 23 PGND 22 IN 21 REG 20 VDD 19 DL1 18 LX1 17 DH1 16 BST1 15 EN1 TSSOP *CONNECT EXPOSED PAD TO GROUND PLANE. MAX15034A DOES NOT HAVE AN EXPOSED PAD. ______________________________________________________________________________________ 25 Configurable, Single-/Dual-Output, Synchronous Buck Controller for High-Current Applications MAX15034 Revision History REVISION NUMBER 0 1 REVISION DATE 7/08 10/11 Initial release Updated Ordering Information. DESCRIPTION PAGES CHANGED — 1 MAX15034 Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. 26 ____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600 © 2011 Maxim Integrated Products Maxim is a registered trademark of Maxim Integrated Products, Inc.
MAX15034 价格&库存

很抱歉,暂时无法提供与“MAX15034”相匹配的价格&库存,您可以联系我们找货

免费人工找货