MCC
Features
• • • •
omponents 21201 Itasca Street Chatsworth !"# $
% !"#
1N4933 THRU 1N4937
1 Amp Fast Recovery Rectifier 50 - 600 Volts
DO-41
Low Leakage Current Metalurgically Bonded Construction Low Cost Fast Switching
• • •
Maximum Ratings
Operating Temperature: -55 °C to +150°C Storage Temperature: -55°C to +150°C Maximum Thermal Resistance; 30 °C/W Junction To Lead Device Marking Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V Maximum RMS Voltage Maximum DC Blocking Voltage 50V 100V 200V 400V 600V
MCC Catalog Number
D
1N4933 1N4934 1N4935 1N4936 1N4937
-----------
35V 70V 140V 280V 420V
A Cathode Mark B
D
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward Current Peak Forward Surge Current Maximum Instantaneous Forward Voltage Maximum DC Reverse Current At Rated DC Blocking Voltage Maximum Reverse Recovery Time Typical Junction Capacitance IF(AV) IFSM 1.0A 30A TA =55°C
C
8.3ms, half sine
VF
1.3V 5.0µA 100µA 200ns
IFM = 1.0A; TJ = 25°C* TJ = 25°C TJ = 125°C IF=1.0A, VR=30V Measured at 1.0MHz, VR=4.0V
DIMENSIONS INCHES MIN .166 .080 .028 1.000 MM MIN 4.10 2.00 .70 25.40
IR
Trr
DIM A B C D
MAX .205 .107 .034 ---
MAX 5.20 2.70 .90 ---
NOTE
CJ
15pF
*Pulse test: Pulse width 300 µsec, Duty cycle 1%
www.mccsemi.com
1N4933 thru 1N4937
Figure 1 Typical Forward Characteristics 20 10 6 4 1.0 2 Amps 1 .6 .4 .2 25°C .1 .06 .04 .02 .01 .4 .6 .8 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts 1.0 1.2 1.4 0 .2 Amps .4 .8 1.2 Figure 2 Forward Derating Curve
MCC
.6
Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 50 75 100 °C Average Forward Rectified Current - Amperes ersus v Ambient Temperature - °C 125 150 175
Figure 3 Junction Capacitance
100 60 40 20 pF 10 6 4 2 1 .1 .2 .4 1 Volts 2 4 10 20 40 100 200 400 1000 TJ=25°C
Junction Capacitance - pFversus Reverse Voltage - Volts
www.mccsemi.com
1N4933 thru 1N4937
Figure 4 Typical Reverse Characteristics 100 60 40 20 10 6 4 T =100°C A 2 µ Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 20 40 60 80 Volts Instantaneous Reverse Leakage Current - MicroAmperes ersus v Percent Of Rated Peak Reverse Voltage - Volts Figure 6 Reverse Recovery Time Characteristic And Test Circuit Diagram 100 120 140 TA=25°C Amps 60 50 40 30 20 10 5 0
MCC
Figure 5 Peak Forward Surge Current
1
2
4
6
8 10 Cycles
20
40
60 80 100
Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles
www.mccsemi.com
很抱歉,暂时无法提供与“1N4933”相匹配的价格&库存,您可以联系我们找货