MCC
Micro Commercial Components
TM
omponents 20736 Marilla Street Chatsworth !"# $
% !"#
M B805 THRU MB810
8 Amp Single Phase Bridge Rectifier 50 to 1000 Volts
BR-6
B
Features
• • • •
•
Mounting Hole For #6 Screw Any Mounting Position Surge Rating Of 125 Amps Case Material: Molded Plastic. UL Flammability Classification Rating 94V-0 and MSL Rating 1 Lead Free Finish/RoHS Compliant (NOTE 1)("P" Suffix designates RoHS Compliant. See ordering information)
Maximum Ratings
• • • Operating Temperature: -55 °C to +125°C Storage Temperature: -55°C to +150°C UL Recognized File # E165989 Microsemi Catalog Number Device Marking Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V Maximum RMS Voltage Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000V
C
MB805 MB81 MB82 MB84 MB86 MB88 MB810
MB805 MB81 MB82 MB84 MB86 MB88 MB810
35V 70V 140V 280V 420V 560V 700V
E D G + AC A AC -
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element Maximum DC Reverse Current At Rated DC Blocking Voltage
Notes:
IF(AV) IFSM VF
8.0A 125A
TC = 50°C 8.3ms, half sine
A
1.1V
IFM = 4.0A per element; TA = 25°C (Note 2) TJ = 25°C TJ = 100°C
DIM A B C D E G INCHES MIN .578 .230 .750 .405 .038 .145
DIMENSIONS MM MIN 14.69 5.84 19.10 10.30 0.97 3.70
IR
10µA 1mA
1. High Temperature Solder Exemption Applied, see EU Directive Annex Notes 7 2. Pulse Test: Pulse Width 300usec, Duty Cycle 1%
MAX .618 .270 --.444 .042 ---
MAX 15.71 6.86 --11.30 1.07 ---
NOTE 2PL
2PL 4PL/TYP ∅
www.mccsemi.com
Revision: 6
1 of 3
2008/01/30
MB805 thru MB810
Figure 1 Typical Forward Characteristics 100 60 40 20 10 6 4 2 25°C Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 .2 .4 .6 .8 1.0 1.2 1.4 10 6 4 2 1 .6 .4 .2 TJ=25°C µAmps .1 .06 .04 .02 .01 .006 .00 4 .002 .001 20 40 60
MCC
TM
Micro Commercial Components Figure 2 Typical Reverse Characteristics
80 Volts
100
120
140
Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Figure 3 Forward Derating Curve 12
Instantaneous Reverse Leakage Current - MicroAmperes ersus v Percent Of Rated Peak Reverse Voltage - Volts
Figure 4 Maximum Non-Repetitive Forward Surge Current 150
10
125 100 75 Amps 50 25
8
6 Amps 4
2
Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 25 50 75 °C Average Forward Rectified Current - Amperes ersus v Ambient Temperature - °C 100 150 175
0
1
2
4
6
8 10 Cycles
20
40
60 80 100
0
Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles
Revision: 6
www.mccsemi.com
2 of 3
2008/01/30
MCC
Device
TM
Micro Commercial Components
Ordering Information
Packing Bulk;200pcs/Box (Part Number)-BP
***IMPORTANT NOTICE*** Micro Commercial Components Corp . reserves the right to make changes without further notice to any product herein to make corrections, modifications , enhancements , improvements , or other changes . Micro Commercial Components Corp . does not assume any liability arising out of the application or use of any product described herein; neither does it convey any license under its patent rights ,nor the rights of others . The user of products in such applications shall assume all risks of such use and will agree to hold Micro Commercial Components Corp . and all the companies whose products are represented on our website, harmless against all damages. ***APPLICATIONS DISCLAIMER*** Products offer by Micro Commercial Components Corp . are not intended for use in Medical, Aerospace or Military Applications.
www.mccsemi.com
Revision: 6
3 of 3
2008/01/30
很抱歉,暂时无法提供与“MB84”相匹配的价格&库存,您可以联系我们找货