MCC
Micro Commercial Components
TM
omponents 20736 Marilla Street Chatsworth !"# $
% !"#
MLESD12A-0402
Features
• ESD protection for high speed data lines to IEC61000-4-2 ESD contact discharge 8KV, max 15KV IEC61000-4-2 ESD air discharge 15KV, max 25KV Multilayer structure Surface mount Extremely low capacitance Very low leakage current Fast response time Bi-directional ESD protection Lead free solder termination The best ESD protection for high frequency, low voltage applications
Multilayer Polymer
ESD Suppressor
0402
• • • • • • • •
Application
• • • • • • • High Definition Multi-Media Interface (HDMI) Digital Visual Interface (DVI) Display Port Interface Unified Display Interface (UDI) MDDI Ports Gigabit Ethernet USB2.0 and IEEE1394 interface
Suggested Solder Pad Layout
G
* Caution: This component is designed for signal line protection only, not intended to be used under bias, not for application with a power line.
Environmental Specifications
• • • • • • Operation temperature: -40~90 Moisture Resistance, Steady state: MIL-STD-833,Method 1004.7, 85% RH,85 ,1000hrs Thermal Shock: MIL-STD-202,Method 107G,-55 to150 ,30 min cycle,10 cycles. Vibration: MIL-STD-202F, Method 201A, (10 to 55 to 10HZ, 1 min. cycle, 2hrs each in X-Y-Z) Chemical Resistance: ASTM D-543, 4hrs @40 , 3 solutions(H2O,
detergent solution, deluxer )
E
F
DIMENSIONS
Solder leach resistance and terminal adhesion: Per EIA-576 test
DIM A B C D E F G
INCHES MIN MAX .037 .045 .017 . 02 6 .013 .017 .010 .014 .024 .028 .01 7 .022 .033 .037
MM
MIN 0.95 0.45 0.33 0.25 0.60 0.45 0.85
MAX 1.15 0.65 0.43 0.35 0.70 0.55 0.95
NOTE
Revision: 1
www.mccsemi.com
1 of 4
2009/01/01
MLESD12A-0402
Electrical Characteristics
Electrical Characteristics
MCC
Micro Commercial Components
TM
Parameter
Symbol
Conditions
Min
Typ
Max
Units
Continuous operating voltage
VDC
---
---
---
12
V
Trigger voltage
VT
IEC61000-4-2 8KV contact discharge
---
300
---
V
Clamping voltage
VC
IEC61000-4-2 8KV contact discharge
---
20
---
V
Leakage current
IL
12V VDC
---
0.10
10
nA
Capacitance
CP
VR = 0V, f = 1MHz
---
0.15
0.3
pF
Operating Temperature
---
---
-40
---
90
Storage Temperature
---
---
-55
---
150
ESD pulse withstand
Pulses
IEC61000-4-2 8KV contact discharge
2000
---
---
---
Notes: 1, Trigger and clamping voltage measure per IEC 61000-4-2, 8KV contact discharge method
Typical MLESD clamping for +8KV pulse per IEC61000-4-2
Revision: 1
www.mccsemi.com
2 of 4
2009/01/01
MLESD12A-0402
MC C
Micro Commercial Components
TM
Design Recommendations for USB2.0
For USB2.0 port
MLESD12A-0402
Design Recommendations for Antenna
For antenna line
MLESD12A-0402
Revision: 1
www.mccsemi.com
3 of 4
2009/01/01
MCC
Micro Commercial Components
TM
Ordering Information
Device (Part Number)-TP Packing Tape&Reel;10Kpcs/Reel
***IMPORTANT NOTICE*** Micro Commercial Components Corp . reserves the right to make changes without further notice to any product herein to make corrections, modifications , enhancements , improvements , or other changes . Micro Commercial Components Corp . does not assume any liability arising out of the application or use of any product described herein; neither does it convey any license under its patent rights ,nor the rights of others . The user of products in such applications shall assume all risks of such use and will agree to hold Micro Commercial Components Corp . and all the companies whose products are represented on our website, harmless against all damages. ***APPLICATIONS DISCLAIMER*** Products offer by Micro Commercial Components Corp . are not intended for use in Medical, Aerospace or Military Applications.
Revision: 1
www.mccsemi.com
4 of 4
2009/01/01
3
很抱歉,暂时无法提供与“MLESD12A-0402-TP”相匹配的价格&库存,您可以联系我们找货