MCC
Features
• • • •
omponents 21201 Itasca Street Chatsworth !"# $
% !"#
SDB101 THRU SDB107
1 Amp Single Phase Glass Passivated Bridge Rectifier 50 to 1000 Volts
SDB-1
B
Surface Mount Package Glass Passivated Diode Construction Moisture Resistant Epoxy Case High Surge Current Capability
Maximum Ratings
• • MCC Catalog Number SDB101 SDB102 SDB103 SDB104 SDB105 SDB106 SDB107 Device Marking
Operating Temperature: -55 °C to +150°C Storage Temperature: -55°C to +150°C Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000V
∼
+ ∼
D
C
K
Notch in Case
A
---------------
G E
H DIMENSIONS INCHES MIN .320 .245 .040 .386 .120 .002 .195 .040 MM MIN 8.13 6.20 1.02 9.80 3.05 0.05 5.00 1.02
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward IF(AV) 1A TA = 40°C Current Peak Forward Surge IFSM 50A 8.3ms, half sine Current Maximum 1.1V IFM = 1.0A; Instantaneous VF Forward Voltage TA = 25°C Maximum DC Reverse Current At IR 10µA TA = 25°C Rated DC Blocking 0.5mA TA = 125°C Voltage Maximum Reverse Trr 36ns IF=0.5A, IR=1.0A, Recovery Time Irr=0.25A Typical Junction CJ 25pF Measured at Capacitance 1.0MHz, VR=4.0V *Pulse Test: Pulse Width 300 µsec, Duty Cycle 1%
DIM A B C D E G H K
MAX .335 .255 .060 .404 .130 .008 .205 .047
MAX 8.50 6.50 1.52 10.3 3.30 0.20 5.20 1.20
NOTE
TYP
Suggested Solder Pad Layout
.047”
.344” .060”
.205”
Version: 3
www.mccsemi.com
2003/01/08
SDB101 thru SDB107
Figure 1 Typical Forward Characteristics 20 10 6 4 2 25°C Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 .4 .6 .8 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts 1.0 1.2 1.4 20 10 6 4 2 µ Amps 1 .6 .4 .2 .1 .06 .04 .02 .01 20 40 60 80 Volts 100 60 40
MCC
Figure 2 Typical Reverse Characteristics
TA=25°C
100
120
140
Instantaneous Reverse Leakage Current - MicroAmperes ersus v Percent Of Rated Peak Reverse Voltage - Volts
Figure 3 Forward Derating Curve 1.2 60 1.0 50 40 30 .6 Amps .4 Amps 20 10 5 0 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 0 50 75 100 °C Average Forward Rectified Current - Amperes ersus v Ambient Temperature - °C 125 150 175
Figure 4 Peak Forward Surge Current
.8
.2
1
2
4
6
8 10 Cycles
20
40
60 80 100
Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles