300W Modified Sine Wave DC-AC Power Inverter
Features :
A-301/302-300 series
12V or 24V DC input Power ON-OFF switch Input voltage range: -15% ~ +25% Output voltage regulation: 10% Protections: Bat. Low alarm/Bat. Low shutdown/Over voltage/ Over temp./Output short/Input polarity reverse/Over load. Output waveform: Modified sine wave Cooling fan ON-OFF control Topology: Microprocessor Approvals: e13/ CE 1 year warranty
SPECIFICATION
ORDER NO. SAFETY MODEL NO. AC VOLTAGE RATED POWER SURGE POWER OUTPUT WAVEFORM FREQUENCY AC REGULATION STANDARD RECEPTACLES LED INDICATOR DC CURRENT NO LOAD CURRENT DRAW DC VOLTAGE INPUT VOLTAGE RANGE EFFICIENCY (Typ.) DC CONNECTOR FUSE BAT. LOW ALARM BAT. LOW SHUTDOWN OVER VOLTAGE PROTECTION OVER TEMPERATURE OUTPUT SHORT BAT. POLARITY WORKING TEMP. ENVIRONMENT WORKING HUMIDITY A301-300-B2 A-300-300W 110V 300W 600W Modified Sine Wave 60Hz 1% 10% TYPE-2* 2ea 35A 0.36A 12V 10 ~ 15VDC 82% Cigarette plug*1ea, Battery clip*1ea Battery cord 35 A * 1, Cigarette plug 15 A* 1 10 0.5V 9.5 0.5V 15 ~ 17V 45 5 / 113 9 F
o
ES
Germany
EMC
tested
ES
Germany
LVD
tested
A301-300-F3 230V
A302-300-B2 110V
A302-300-F3 230V
50Hz 1% TYPE-3* 1ea
60Hz 1% 10% TYPE-2* 2ea 15A 0.2A 24V 21 ~ 30VDC
50Hz 1% TYPE-3* 1ea
Green LED for power on; Red LED for power failure status
85% Cigarette plug*1ea, Battery clip*1ea Battery cord 20 A * 1, Cigarette plug 10 A* 1 20 0.8V 19.5 0.8V 30 ~ 32V
Shut-off By fuse open 0 ~ 30 @ 100% load, 40 @ 50% load 20% ~ 90% RH non-condensing
SAFETY & EMC
o STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH TEMP. COEFFICIENT 0.05% / (0 ~ 50 ) I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE Compliance to EN61000-4-2,3 EMS IMMUNITY
OTHERS
LVD MTBF DIMENSION PACKING COOLING APPLICATIONS
Compliance to EN60950 200Khrs min. MIL-HDBK-217F (25 165*88*74mm (L*W*H) 1.1kg ; 16pcs / 19kg / CARTON )
>100W or >40 (NTC) fan on Home appliance, Power tools, Office and Portable equipment and Vehicle ...etc.
AC Output Receptacles (optional)
TYPE-1 JAPAN
TYPE-2 USA
TYPE-3 EUROPE
TYPE-4 UNIVERSAL
TYPE-5 AUSTRALIA
TYPE-6 U.K
File Name: A-301/302-300-SPEC 2007-05-14
300W Modified Sine Wave DC-AC Power Inverter
Mechanical Specification
88
A-301/302-300 series
Unit:mm
74
165
AIR FLOW
AC OUTPUT
ON
OFF
BAT.LOW OVER TEMP. OVER LOAD
P OWER
BAT.LOW OVER TEMP. OVER LOAD
POWER
USA
EUROPE
File Name: A-301/302-300-SPEC 2007-05-14
18.5
WARING: DO NOT REVERSE INPUT
MADE IN TAIWAN