SPECIFICATION
MODEL RATED CURRENT DC VOLTAGE RANGE RATED POWER VOLTAGE TOLERANCE Note.3 CURRENT ACCURACY LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY(Typ.) AC CURRENT INRUSH CURRENT(max.) LEAKAGE CURRENT PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC
(Note 5) Note.4
SELV
LPS
APC-12-350 350mA 9~36V 12.6W 5.0% 5.0% 1.0% 3.0% 3000ms, 180ms / 230VAC 90 ~ 264VAC 47 ~ 63Hz 82% 0.2A/230VAC;0.35A/115VAC Cold start 35A/115VAC,70A/230VAC 0.25mA / 240VAC 39.6~ 46.8V Protection type : Shut off o/p voltage, clamping by zener diode -30 ~ 70 -40 ~ +80 0.2%/ (Refer to "Derating Curve") , 10 ~ 95% RH (0 ~ 50 ) 20 ~ 90% RH non-condensing 3000ms, 150ms / 115VAC at full load 20ms/230VAC,15ms/115VAC at full load 127 ~ 370VDC
APC-12-700 700mA 9~18V 12.6W 250mVp-p
RIPPLE & NOISE (max.) Note.2 300mVp-p OUTPUT
80%
20.7~ 24.3V
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Design refer to TUV EN60950-1, EN61347-2-13, UL8750 I/P-O/P:3.75KVAC I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015,EN61000-3-2 Class A,EN61000-3-3 Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A 1145.7K hrs min. MIL-HDBK-217F (25 ) 77*40*29(L*W*H) 0.08Kg; 120pcs/11.8Kg/0.93CUFT
EMC EMISSION EMC IMMUNITY MTBF
OTHERS
NOTE
DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristic for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
File Name: APC-12-SPEC 2011-07-09
12W Single Output Switching Power Supply
Mechanical Specification
APC-12
series
Unit:mm
90 82.5
77
150 10
+V(Red) -V(Black)
19
31 T case
AC/N(Blue) AC/L(Brown)
UL1569 18AWG 150 10
15.5
40
UL1569 20AWG
T case: Max. Case Temperature
Block Diagram
POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT PWM CONTROL
29
fosc : 67KHz
I/P
EMI FILTER
RECTIFIERS
+V -V
Derating Curve
100
Static Characteristics
100 90
80
80 70
60
LOAD (%)
LOAD (%)
0 10 20 30 40 45 50 60 70 (HORIZONTAL)
50 40
60 50 40
20
-30
90
100
200
210
220
230
240
250
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name: APC-12-SPEC 2011-07-09