75W Single Output LED Power Supply
½ Features :
CEN-75
series
Universal AC input / Full range (up to 295VAC) Protections: Short circuit / Overload / Over voltage / Over temperature Output voltage and constant current level adjustable Built-in active PFC function IP66 design for indoor or outdoor installations Cooling by free air convection 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting Suitable for dry / damp / wet locations 3 years warranty
F
110
M
M
SELV
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT CEN-75-15 15V 5A 0 ~ 5A 75W CONSTANT CURRENT OPERATION VOLTAGE Note.5 11.25 ~ 15V CEN-75-20 20V 15 ~ 20V 3.75A 0 ~ 3.75A 75W 2Vp-p 17 ~ 22V 2.81 ~ 3.75A CEN-75-24 24V 18 ~ 24V 3.15A 0 ~ 3.15A 75.6W 2.7Vp-p 22 ~ 27V 2.36 ~ 3.15A CEN-75-30 30V 22.5 ~ 30V 2.5A 0 ~ 2.5A 75W 3Vp-p 27 ~ 33V 1.88 ~ 2.5A
IP66
CEN-75-36 36V 27 ~ 36V 2.1A 0 ~ 2.1A 75.6W 3.6Vp-p 33 ~ 40V 1.58 ~ 2.1A CEN-75-42 42V 31.5 ~ 42V 1.8A 0 ~ 1.8A 75.6W 4Vp-p 37 ~ 46V 1.35 ~ 1.8A CEN-75-48 48V 36 ~ 48V 1.57A 0 ~ 1.57A 75.36W 4.6Vp-p 43 ~ 53V 1.18 ~ 1.57A CEN-75-54 54V 40.5 ~ 54V 1.4A 0 ~ 1.4A 75.6W 5Vp-p 49 ~ 58V 1.05 ~ 1.4A
RIPPLE & NOISE (max.) Note.2 2.7Vp-p VOLTAGE ADJ. RANGE (SVR1) 13.5 ~ 17V CURRENT ADJ. RANGE(SVR2) 3.75 ~ 5A VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP TIME VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER CURRENT SHORT CIRCUIT PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC ISOLATION RESISTANCE 10% 3.0% 5.0%
1400ms / 230VAC 2800ms / 115VAC at full load
Note.4 90 ~ 295VAC
127 ~ 417VDC PF>0.95 / 230VAC at full load 90% 91% 91%
47 ~ 63Hz PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC ; PF>0.97 / 115VAC 87% 1.1A/115VAC 45A/230VAC 95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed 17.5 ~ 21V 22.8 ~ 26V 28 ~ 34V 34 ~ 38V 41 ~ 46V Protection type : Shut down o/p voltage, re-power on to recover 85 10 (RTH1) (Refer to output load derating curve) , 10 ~ 95% RH (0 ~ 50 ) Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 -40 ~ +80 0.03%/ 20 ~ 95% RH non-condensing 47 ~ 52V 54 ~ 60V 59 ~ 65V 88% 0.55A/230VAC 89% 90% 90%