60W Single Output Class 2 Switching Power Supply
Features :
ELN-60
series
Universal AC input / Full range Protections: Short circuit / Over current / Over voltage Cooling by free air convection Built-in constant current limiting circuit with adjustable OCP level Optional dimming function : 1~10VDC (D type) or PWM (P type) controlled Fully isolated plastic case with IP64 level Class power unit, no FG Class 2 power unit Pass LPS Suitable for LED lighting and moving sign applications (Note.9) 100% full load burn-in test Low cost, high reliability 2 years warranty
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER ELN-60-9 9V 5A 0 ~ 5A 45W 8.7 ~ 10.5V LED OPERATION VOLTAGE Note.8 3 ~ 9V ELN-60-12 12V 6 ~ 12V 5A 0 ~ 5A 60W 120mVp-p 10.8 ~ 13.2V ELN-60-15 15V 7.5 ~ 15V 4A 0 ~ 4A 60W 150mVp-p 13.5 ~ 16.5V
LPS IP64
ELN-60-24 24V 12 ~ 24V 2.5A 0 ~ 2.5A 60W 150mVp-p 21.6 ~ 26.4V
( for 48V only)
( except for 48V )
ELN-60-27 27V 13.5 ~ 27V 2.3A 0 ~ 2.3A 62.1W 200mVp-p 24.3 ~ 29.7V
ELN-60-48 48V 24 ~ 48V 1.3A 0 ~ 1.3A 62.5W 250mVp-p 43.2 ~ 52.8V
RIPPLE & NOISE (max.) Note.2 120mVp-p OUTPUT VOLTAGE ADJ. RANGE Note.7
Can be adjusted by internal potentiometer SVR1 5.0% 1.0% 2.0%
CURRENT ADJ. RANGE Note.7 -25% ~ 3%. Can be adjusted by internal potentiometer SVR2 VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (max.) LEAKAGE CURRENT OVER CURRENT PROTECTION OVER VOLTAGE
Note.6 500ms, 30ms / 230VAC
1500ms, 30ms / 115VAC at full load
50ms/230VAC
Note.4 90 ~ 264VAC
16ms/115VAC at full load 127 ~ 370VDC 85% 86% 87% 87% 88%
47 ~ 63Hz 82% 1.2A/115VAC 0.7A/230VAC COLD START 60A/230VAC 0.25mA / 240VAC 95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed 11 ~ 13.5V 13.8 ~ 16V 17.5 ~ 21V 28 ~ 32V 31 ~ 35V 54 ~ 60V
Protection type : Shut down o/p voltage, re-power on to recover FUNCTION DIMMING CONTROL (OPTIONAL) 1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & EMC WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING
NOTE
-20 ~ +60
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing -40 ~ +80 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1 I/P-O/P:3KVAC I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A 603Khrs min. MIL-HDBK-217F (25 181*61.5*35mm (L*W*H) 0.4Kg; 24pcs/11Kg/0.75CUFT )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB. 8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications. 9. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name:ELN-60-SPEC 2012-03-20
60W Single Output Class 2 Switching Power Supply
Mechanical Specification
181 6.26
ELN-60
Case No.960A
series
Unit:mm
21.25
2-R2.5
300 2 0
15
SVT 18AWG 2C
6.26
T case: Max. Case Temperature.
21.25
AC/L(Brown) AC/N(Blue)
61.5
300 20
+V(Red) -V(Black)
T case
SVT 18AWG 2C
116.5
OUTPUT(with optional dimming function)
Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2 shown in the diagram.
+V(Red) -V(Black) DIM+(Blue) DIM-(White)
UL2464 18AWG 4C
SVR1 SVR2
SVR1 Output voltage adjustment SVR2 Output current adjustment
Block Diagram
I/P EMI FILTER & RECTIFIERS POWER SWITCHING RECTIFIERS & FILTER DETECTION CIRCUIT PWM CONTROL O.V.P. O.C.P.
fosc : 60KHz
+V -V DIM10V PWM or 1~10V DIM+ Optional Dimming Control
O.L.P.
Derating Curve
Static Characteristics
100
100 90
80
80 70
60
LOAD (%)
40
LOAD (%)
50
60 50 40
20
-20
-15
-5
0
15
30
40 45 50
60 (HORIZONTAL)
90
100
125
135
145
155 165
175
180
200
230
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:ELN-60-SPEC 2012-03-20
35
60W Single Output Class 2 Switching Power Supply
Dimming Control (Optional)
Level of output current can be adjusted through the dimming control function. When there is no signal sending to the control wires (open circuit between the two control wires), the power supply unit will operate as 0V (D-type) or 0% duty (P-type) of input signal and hence the output current will be zero. ( 1)1~10V (D type, & : ELN-60- 12 D)
ELN-60
series
95%
DIM+
Vdc
Output Current
+
DIMVdc: 1~10V
100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0
45%
5% 1 2 3 4 5 6 7 8 9 10
DC Input
(2)PWM (P type, & : ELN-60- 12 P)
V f: 100Hz ~ 3KHz
100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% 0% 11% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%
Output Current
f 10V
60%
t1
t2
f
15%
Duty= t1 ,0 ~ 100% t1+t2 Lo:0V Hi:10V
Duty Cycle
File Name:ELN-60-SPEC 2012-03-20