10 ~ 15W AC-DC Single Output Interchangeable Wall-mounted type
Features :
GE12
series
Interchangeable AC plugs (plug kit sold seperately) Universal AC input / Full range No load power consumption< 0.3W ErP step2 compliant Meet EISA 2007 (Energy Independence and Security Act) for 5~24V Class power (without earth pin) Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case LED indicator for power on Pass LPS Approvals: UL / CUL / TUV / CCC / CB / FCC / CE / C-Tick 2 years warranty
AC INLET PLUG
TYPE Australian type ORDER NO. AC plug-AU U.K type AC plug-UK European type AC plug-EU US type AC plug-US Mix four type AC plug-MIX
SPECIFICATION
POWER SUPPLY MAIN BODY ORDER NO. GE12 I 05-P1J SAFETY MODEL NO. DC VOLTAGE RATED CURRENT CURRENT RANGE OUTPUT RATED POWER VOLTAGE TOLERANCE Note.4 LINE REGULATION LOAD REGULATION
Note.5 Note.6
II
GE12 I 07-P1J FRA012-S07- I 7.5V 1.33A 0 ~ 1.33A 10W 75mVp-p 5.0% 1.0% 5.0%
II
II
GE12 I 09-P1J FRA012-S09- I 9V 1.33A 0 ~ 1.33A 12W 100mVp-p 5.0% 1.0% 5.0%
II
II
GE12 I 12-P1J FRA012-S12- I 12V 1.0A 0 ~ 1.0A 12W 120mVp-p 3.0% 1.0% 3.0%
II
II
GE12 I 15-P1J FRA012-S15- I 15V 0.8A 0 ~ 0.8A 12W 150mVp-p 3.0% 1.0% 3.0%
II
II
GE12 I 18-P1J FRA012-S18- I 18V 0.83A 0 ~ 0.83A 15W 180mVp-p 3.0% 1.0% 3.0%
II
II
GE12 I 24-P1J FRA012-S24- I 24V 0.625A 0 ~ 0.625A 15W 240mVp-p 3.0% 1.0% 3.0%
II
FRA012-S05- I
Note.2 5V
2.0A 0 ~ 2.0A 10W 5.0% 1.0% 5.0%
RIPPLE & NOISE (max.) Note.3 50mVp-p
SETUP, RISE, HOLD UP TIME 4000ms, 100ms, 30ms / 230VAC VOLTAGE RANGE 90 ~ 264VAC 135 ~ 370VDC FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT (max.) OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY 47 ~ 63Hz 74% 0.4A / 100VAC 77% 0.25A / 230VAC
II
4000ms, 100ms, 10ms / 115VAC at full load
79% 80A / 230VAC
81%
82%
83%
83%
COLD START 40A / 100VAC
0.25mA / 240VAC 110% ~ 200% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 115% ~ 135% Protection type : Clamp by zener diode -10 ~ +50 (Refer to "Derating Curve") 20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03% / (0 ~ 40 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMC EMISSION EMC IMMUNITY LIFE OTHERS MTBF DIMENSION PACKING UL60950-1, CSA C22.2, TUV EN60950 -1, CCC GB4943 approved I/P-O/P:4242VDC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254 class B Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 2 years : 100% load 30 , 8 hours / day 100Khrs min. MIL-HDBK-217F (25 ) 70.7*40*38.8mm (L*W*H) 97g ; 60pcs / 6.88kg / CARTON Standard type P1J: 2.1 See page2 * 5.5 * 11mm turning fork type, center positive for stock ; Other type available by customer requested
DC OUTPUT PLUG CONNECTOR CABLE NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 10% to 100% rated load 7.Main body unit and AC inlet plug should be ordered seperately ; it needs to be used along with any of the AC inlet plug.
File Name:GE12-SPEC 2011-06-14
II
10 ~ 15W AC-DC Single Output Interchangeable Wall-mounted type
Mechanical Specification
GE12
series
Unit:mm
AWM2468 20AWG*2C 1500 50mm
ID 2.1 x OD 5.5 C"+"
40
11 0.5mm
70.7
Plug Assignment
Standard plug: P1J P1J
P/N CENTER OUTPUT +
38.8
Derating Curve
29.8
Static Characteristics
100
100
90 80
LOAD (%)
75 70
LOAD (%)
10 20 30 40 50
50
60 50 40
-10
90
95
100
115
120
140
160
180
200
220
240
264
Ta (
)
File Name:GE12-SPEC 2011-06-14