160W Single Output Battery Charger
Features :
2 stage charging characteristic Universal AC input / Full range
GC160
Built-in active PFC function, PF>0.94 No load power consumption0.94 / 230VAC 89% 1.85A / 115VAC 120A / 230VAC 0.75mA / 240VAC 1A / 230VAC PF>0.98 / 115VAC at full load 92.5% 94%
INPUT
EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT(max.) OVERLOAD SHORT CIRCUIT
90 ~ 110% rated output power Note.4 Protection type : Constant current limiting recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover 90 10 (RTH2) detect on inside ambient temperature Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to "Derating Curve") 20% ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03% / (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012 (for GC160Axx-AD1 only), TUV EN60950-1 approved I/P-O/P: 3KVAC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
PROTECTION
OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 5) EMC EMISSION EMC IMMUNITY OTHERS MTBF DIMENSION PACKING PLUG CABLE
Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B, EN61000-3-2,3 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 274.1Khrs min. MIL-HDBK-217F(25 ) 175*72*35mm (L*W*H) 0.7Kg; 20pcs/15Kg/0.85CUFT(GC160Axx-R7B) 0.77Kg; 20pcs/16.4Kg/1.15CUFT(GC160Axx-AD1) See page 2 ; Other type available by customer requested See page 2 ; Other type available by customer requested
CONNECTOR NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. This is MeanWell's suggested range, please consult your battery manufacturer for their suggestions about maximum charging current limitation. 3. Derating may be needed under low input voltage. Please check the derating curve for more details. 4. Constant current operation region is within 50~100% rated output voltage. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
File Name:GC160-SPEC 2011-08-09
160W Single Output Battery Charger
Mechanical Specification
GC160
Case No.997A
series
Unit:mm
35
175
UL2464 18AWGx4C 1200 50mm POWER LED
30 3mm
23 14
(R7B)
72
35
175
SJTW 16AWGx2C 1200 50mm POWER LED
30 3mm
72
(AD1)
Plug Assignment
DC output connector (standard)
R7B (KYCON KPP-4S or equivalent) PIN NO. OUTPUT
2 1 3 4
Charging Curve
(V,I) Stage 1 Constant Current Area Stage 2 Constant Voltage Area V
1,4 2,3
+V -V
100% Fast Charging 10% Float Charging I TIME
AC FG -V connected to AC FG
DC output connector (optional)
AD1 [ housing: Anderson 1327FP(red), 1327G6FP(black) contacts: Anderson 261G2 (45A) or equivalent ] Red(+V) Black(-V)
Color of LED
Red
Green
Derating Curve
100
Static Characteristics
230VAC
100 85
80
80
60
100VAC
70
LOAD (%)
LOAD (%)
10 20 30 40 50 60 70
50 40
60 50 40
20
-30
(HORIZONTAL)
85
95
100
110
120
140
160
180
200
220
240
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz