120W AC-DC Single Output Desktop
Features :
GS120
Universal AC input / Full range 3 pole AC inlet IEC320-C14 Built-in active PFC function, PF>0.97
series
Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case Approvals: UL / CUL / PSE / TUV / BSMI / CCC / CB / FCC / CE Class power (with earth pin) LED indicator for power on No load power consumption0.99 / 115VAC at full load 89% ----0.7A / 230VAC 89% 88.5% 90% 89.5% 91% 90.5%
47 ~ 63Hz PF>0.97 / 230VAC 87.5% ----1.4A / 115VAC 70A / 230VAC 0.75mA / 240VAC 105 ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover RTH2 100 10 Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to "Derating Curve") 20% ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03% / (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1(except for 48V) approved I/P-O/P: 3KVAC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT(max.) OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note. 5) EMC EMISSION EMC IMMUNITY OTHERS MTBF DIMENSION PACKING PLUG CABLE
Compliance to EN55022(CISPR22) ,EN61204-3 class B, CNS13438 class B, GB9254-1 class B, FCC PART 15, EN61000-3-2,3, GB17625.1 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 400.7Khrs min. MIL-HDBK-217F(25 ) 167*67*35mm (L*W*H) 0.62Kg; 20pcs/13.4Kg/0.9CUFT See page 2 ; Other type available by customer requested See page 2 ; Other type available by customer requested
CONNECTOR NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Tolerance: includes set up tolerance, line regulation, load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:GS120-SPEC 2012-03-06
120W AC-DC Single Output Desktop
Mechanical Specification
GS120
Case No.GS120A
series
Unit:mm
35
167
UL2464 18AWGx4C 1200 50mm
30 3mm
23 14
67
POWER LED
35
167
UL2464 16AWGx2C 1200 50mm
30 3mm
11
C"+"
67
Outside
Inside
POWER LED
Plug Assignment
Standard plug (all models)
R7B
PIN NO. OUTPUT
2 1 3 4
Standard plug(For 20V,24V,48V only)
11
P1M
P/N CENTER OUTPUT +
ID 2.5 x OD 5.5
C"+"
1,4 2,3
+V -V
Outside
AC FG -V connected to AC FG -V connected to AC FG
Inside
Derating Curve
Static Characteristics
100
100
230VAC
85
80
80
60
100VAC
70
LOAD (%)
LOAD (%)
10 20 30 40 45 50 60 70
50 40
60 50 40
20
-30
(HORIZONTAL)
85
95
100
110
120
140
160
180
200
220
240
264
AMBIENT TEMPERATURE ( )