160W AC-DC Single Output Desktop
Features :
GS160
Universal AC input / Full range 3 pole AC inlet IEC320-C14 Built-in active PFC function, PF>0.95
series
Protections: Short circuit / Overload / Over voltage / Over temperature Fully enclosed plastic case Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE Class power ( with earth pin) LED indicator for power on No load power consumption0.98 / 115VAC at full load 90% 1A / 230VAC 92% 92.5% 94%
47 ~ 63Hz PF>0.95 / 230VAC 89% 1.85A / 115VAC 120A / 230VAC 0.75mA / 240VAC 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover 90 10 (RTH2) detect on inside ambient temperature Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03% / (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved I/P-O/P: 3KVAC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION Compliance to EN55022(CISPR22) ,EN61204-3 class B, CNS13438 class B, GB9254-1 class B (Note. 5) HARMONIC CURRENT Compliance to EN61000-3-2,3, GB17625.1 EMS IMMUNITY OTHERS MTBF DIMENSION PACKING PLUG CABLE Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 290.3Khrs min. MIL-HDBK-217F(25 ) 175*72*35mm (L*W*H) 0.66Kg; 20pcs/ 14.2Kg/ 0.85CUFT See page 2 ; Other type available by customer requested See page 2 ; Other type available by customer requested
CONNECTOR NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Tolerance: includes set up tolerance, line regulation, load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltage. Please check the derating curve for more details.
File Name:GS160-SPEC 2010-07-12
160W AC-DC Single Output Desktop
Mechanical Specification
GS160
Case No.997A
series
Unit:mm
35
175
UL2464 18AWGx4C 1200 50mm POWER LED
30 3mm
23 14
72
Plug Assignment
Standard plug: R7B R7B
PIN NO. OUTPUT
2 1 3 4
1,4 2,3
+V -V
AC FG -V connected to AC FG
Derating Curve
230VAC
Static Characteristics
100 85
100
80
80
60
100VAC
70
LOAD (%)
LOAD (%)
10 20 30 40 50 60 70
50 40
60 50 40
20
-30
(HORIZONTAL)
85
95
100
110
120
140
160
180
200
220
240
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:GS160-SPEC 2010-07-12